About This Manual
This manual contains information about communicating data by connecting either
of the network units listed below and sensor amplifiers.
Compatible network units
CC-Link compatible network unit, NU-CL1
DeviceNet compatible network unit, NU-DN1
For specific communication procedures, refer to the manual of each network unit.
For the functions of sensor amplifiers, refer to the manual of each sensor amplifier.
96063E
1
Page 4
1
Network unit
1
FS-N14*
FS-N12*
FS-N10
CH1 CH2
3 4
2
ID number
Point
FS-N Series
Number of ID Numbers Occupied
The table below summarizes how many ID numbers are occupied by each model of
sensor amplifier.
ModelNumber of ID numbers occupied
FS-N101
FS-N12*1
FS-N14*2
Connection example:
Data Assignments
Each ID number is assigned an output, setting value, current value, and external input.
ModelItemCh1 (1st ID number)Ch2 (2nd ID number)
OutputOutput
FS-N10
FS-N12*
FS-N14*
2
Setting valueSetting value of output
Current valueReceived light intensity
External inputExternal input
OutputOutput 1Output 2
Setting valueSetting value of output 1Setting value of output 2
Current valueReceived light intensity(Not used)
External inputExternal input(Not used)
The external input can be used after configuring the "Control Input"parameter
of each sensor. (By default, "Control Input" is set to "0: Not use.") The models
FS-N10/N12* do not have an external input wire, but they can utilize external
input via network by using a network unit.
- Sensor Amplifier Network Manual -
-
Page 5
1 FS-N Series
For the FS-N series, the data parameters that can be communicated via a network
unit are specified as follows:
ParameterAvailable settings
Current Value0 to 9999
Setting Value0 to 9999
Current Value Property
Sensor Error
Sensor Warning
Key Lock
Product Code
Head Code(Not used with FS-N)
L-on/D-on (N.O./N.C.)
Over Range(Not used with FS-N)
Under Range(Not used with FS-N)
Invalid(Not used with FS-N)
0: No Error
1: Overcurrent Error
2: Not used
3: EEPROM Error
4: Not used
5: Not used
6: DATUM Correction Error
7: APC Error
There are functions that cannot be set (used) in duplicate. When such functions are
set through communication, the function of lower priority is invalidated while remaining in the set state or is deactivated.
The following table summarizes the functions that cannot be set in duplicated, and
their operations.
Function 1 (Priority: High)Function 2 (Priority: Low)
The digital indicator on the amplifier
displays "---- ----".
Unexecutable
(deactivated)
Unexecutable
(deactivated)
External input is
invalid
Operates as if 110
is set.
The digital indicator on the amplifier
displays "---- ----".
Operates in Normal Detection
Mode.
The digital indicator on the amplifier
displays "---- ----".
Invalid
Unexecutable
(deactivated)
External input is
invalid
Unexecutable
(deactivated)
Unexecutable
(deactivated)
function 2
Sensor
Setting
Error
ON
ON
ON
ON
ON
ON
ON
ON
4
- Sensor Amplifier Network Manual -
Page 7
1 FS-N Series
Parameter List
nn: ID number of sensor amplifier
Example: If the ID number is 13, then: nn30h->1330h, and (nn x 10+3)d->133d
R: Write; W: Read; C: Motion command
InstID: Instance ID; AttrID: Attribute ID
CC-Link DeviceNet
Data
Data no.
category
(Hex)
(Hex)
nn00
nn01 65 Load Recipe Data C
nn02 66 Custom Save C
nn03 67 Maximum Sensitivity Setting C
nn04 68 Percentage Calibration C
nn05 69 Two-point/Pos. Calibration (1st) C
nn06 6A Two-Point Calibration (2nd) C
nn07 6B Positioning Calibration (2nd) C
nn08 6C Full Auto Calibration start C
nn09 6D Full Auto Calibration end C
nn0A 6E Zero-shift start C
nn0B 6F Zero-shift end C
nn0C 70 Preset start C
nn0D 71 Preset end C
nn0E 72 Saturation Canceling start C
nn0F 73 Saturation Canceling end C
nn10 74 Reset Hold Value C
nn11 -
nn1F
nn20
00
nn21 65 Error Information R WORD 0
nn22 66 Warning Information R WORD 0
nn23 67 Warning Function R WORD 0
nn24 68 Output R WORD 0
nn25 69 Current Value R INT 0 0 - 9999
nn26 6A System reserved - - - -
nn27 6B System reserved - - - -
nn28 6C Raw Value R INT 0 0 - 9999
nn29 6D Peak-Hold Value R INT 0 0 - 9999
nn2A 6E Bottom-Hold Value R INT 0 0 - 9999
nn2B 6F System reser
nn2C 70 Peak-Hold Minimum Value R INT 0 0 - 9999
nn2D 71 DATUM Internal
nn2E 72 Display Customize R INT 0
nn2F 73 Slide Switch Status R INT 0
AttrID
Inst ID
(Hex)
64 Group0 Entry count
nn
75 - 83 System reser ved - - - -
64 Group1 Entry count
nn x 10 +1
Name Attribute
*1
*1
ved - - - -
Value R INT 0 0 - 9999
Data
Initial
type
value
R INT 16 16
R INT 19 19
Parameter range
0:No Error 1:Error
Bit 0 Ovecurrent Error
Bit 1 Always 0
Bit 2 EEPROM Error
Bit 3 Always 0
Bit 4 Always 0
Bit 5 DATUM Correction Error
Bit 6 APC Error
Bit 7 Sensor Communication Error
0 : No Warning
1 : Limit Output ON
0 : Not Active
1 : Active
Bit 0 [Out1] 0: Off 1: On
Bit 1 [Out2] 0: Off 1: On
0: No Customize / DATUM
1: Preset
2: Zero-shift
0: Selecting SEL
1: Selecting MEGA
- Sensor Amplifier Network Manual -
5
Page 8
1 FS-N Series
CC-Link DeviceNet
Name Attribute
Data
type
Initial
value
Parameter range
Data
category
(Hex)
Data no.
( H e x )
InstID
AttrID
(Hex)
00
nn30
nn x 10+1
74 Saturation Canceling R INT 0
0: Not Active
1: Active
nn31 75 Operation Mode R INT 0
0: RUN
1: LED_OFF
2: SLEEP
3: PAUSE
nn32 76 Operation Mode Setting R/W INT 0
0: RUN
1: LED_OFF
2: SLEEP
3: PAUSE
nn33 77 Recipe Select R/W INT 0
0 : Initialize
1: Custom
2: Fall
3: Percentage Calibration
4: Zero-shift
5: MEGA
nn34 -
nn3F
78 - 83 System reser ved - - - -
nn40
nn x 10+2
64 Group2 Entry count
*1
R INT 7
7
nn41 65
Setting Value (OUTPUT1/Area
High)
R/W INT 50
0 - 9999
nn42 66 Setting Value (Output2) R/W INT 50 0 - 9999
nn43 67 System reser ved - - - -
nn44 68 Setting Value (Area Low) R/W INT 50 0 - 9999
nn45 69 System reser ved - - -
-
nn46 6A System reserved - - - -
nn47 6B Limit Setting Value R/W INT 0 0
nn48 -
nn4F
6C - 73 System reserved - - - -
nn50 74 [Custom] Group2 Entr y count
*1
R INT 7 7
nn51 75
[Custom] Setting Value
(OUTPUT1/Area High)
R/W INT 50
0 - 9999
nn52 76 [Custom] Setting Value (Output2) R/W INT 50 0 - 9999
nn53 77 System reser ved - - - -
nn54 78 [Custom] Setting Value (Area Low) R/W INT 50 0 - 9999
nn55 79 System reser ved - - - -
nn56 7A System reserved - - - -
nn57 7B [Custom] Limit Setting Value R/W INT 0 0 - 9999
0 : HIGH SPEED (Response Time 50μs)
1: FINE (Response Time 250μs)
2: TURBO (Response Time 500μs)
3: SUPER (Response Time 1ms)
4: ULTRA (Response Time 4ms)
5: MEGA (Response Time 16ms)
nn66 6A Sensitivity Setting R/W INT 0
0: Normal Sensitivity Setting
1: Percentage Calibration
2: Zero-shift Calibration
nn67 6B Percentage Carib. Target Value R/W INT 10 - 99 - +99
nnF9 7D [Custom] Interference Prevention R/W INT 0
0: Normal
1: Double
nnFA 7E [Custom] Parameter Save by Ext-Input R/W INT 1
0: No
1: Yes
nnFB -
nnFF
7F - 83 System reserved - - - -
nn x 10+8
64 Group8 Entry count
*1
R INT 20 20
65 ID Number Count R INT 0
1 for FS-N10/N12*
2 for FS-N14*
66 System reserved - - - -
67 System reserved - - - -
68 Product Code R INT -
0 : FS-N10/N12*
1 : FS-N14*
69 Revision R INT - 0101h
6A Product Name 1,0 R WORD - "FS"
6B Product Name 3,2 R WORD - "-N"
6C Product Name 5,4 R WORD -
"10" for FS-N10/N12*
"14" for FS-N14*
6D Product Name 7,6 R WORD -
"/N" for FS-N10/N12*
"" for FS-N14*
6E Product Name 9,8 R WORD -
"12" for FS-N10/N12*
"" for FS-N14*
6F Product Name 11,10
R WORD -
"*" for FS-N10/N12*
"" for FS-N14
*
70 Product Name 13,12 R WORD - ""
71 Product Name 15,14 R WORD - ""
72 - 83 System reser ved - - - -
nn x 10+7 86 TAG Strings
*2
R/W STR "" (8-byte string)
nn x 10+8 8A Product Name R STR -
"FS-N10/N12*" for FS-N10/N12*
"FS-N14" for FS-N14*
TAG Strings 1,0:4241h
TAG Strings 3,2:4443h
TAG Strings 5,4:4645h
TAG Strings 7,6:4847h
10
* For the character strings handled by the FS-N series, see"TAG String Code
Ta bl e " (page 11).
* The parameters "[Custom] ****" can be saved and recalled using the "Custom
Save" and "Custom (Recipe Select)" functions of the FS-N series.
*1 The "Entry Count" parameters each indicate the number of parameters included in
the given group.
*2 When strings are stored in the "TAG Strings" parameters, the "Sub Display" param-
eter can be set to "TAG Strings" so that the amplifier displays the strings contained
in the "TAG Strings"parameters.
Example: To display the strings on the sensor amplifier as shown below, store data
in the "TAG Strings" parameters as follows:
41 42 43 44 45 46 47 48 h
- Sensor Amplifier Network Manual -
Page 13
1 FS-N Series
Code (Hex) String
7-segment
display
Code (Hex) String
7-segment
display
Code (Hex) String
7-segment
display
20 SP 40 @ 60 `
21 ! 41 A
61 a
22 " 42 B 62 b
23 # 43 C 63 c
24 $ 44 D 64 d
25 % 45 E 65 e
26 & 46 F 66 f
27 ' 47 G 67 g
28 ( 48 H 68 h
29 ) 49 I 69 i
2a * 4a J 6a j
2b + 4b K 6b k
2c , 4c L 6c l
2d - - 4d M 6d m
2e . 4e N 6e n
2f / 4f O 6f o
30 0 50 P 70 p
31 1 51 Q 71 q
32 2 52 R 72 r
33 3 53 S 73 s
34 4 54 T 74 t
35 5 55 U 75 u
36 6 56 V 76 v
37 7 57 W 77 w
38 8 58 X 78 x
39 9 59 Y 79 y
3a : 5a Z 7a z
3b ; 5b [ 7b {
3c < 5c
7c |
3d = = 5d ] 7d }
3e > 5e ^ 7e ~ ~
3f ? 5f _ _ 7f DEL
TAG String Code Table
When strings are stored in the "TAG Strings" parameters, the "Sub Display" parameter can be set to "TAG Strings" so that the amplifier displays the strings contained in
the "TAG Strings" parameters. The character strings available with the FS-N10 series
are as follows:
* If you specify any code that is not assigned to the 7-segment display, the code is
displayed as a blank space on the sensor amplifier.
- Sensor Amplifier Network Manual -
11
Page 14
1 FS-N Series
Revision History
Print dateRevision no.Description
January, 2010Initial release.
February, 2010 Second release.
12
- Sensor Amplifier Network Manual -
Page 15
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for
a period of one (1) year from the date of shipment. If any models or samples were shown
to Buyer, such models or samples were used merely to illustrate the general type and
quality of the Products and not to represent that the Products would necessarily conform
to said models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection
and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
refund the purchase price of, or repair or replace at no charge any Products found to be
defective. This warranty does not apply to any defects resulting from any action of Buyer,
including but not limited to improper installation, improper interfacing, improper repair,
unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, v
are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are
only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products
for Buyer's intended use. KEYENCE will not be responsible for any damages that may
result from the use of the Products.
(3) The Products and any samples (Products/Samples) supplied to Buyer are not to be used
internally in humans, for human transportation, as safety devices or fail-safe systems,
unless their written specifications state otherwise. Should any Products/Samples be
used in such a manner or misused in any way, KEYENCE assumes no responsibility, and
additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any
liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED
WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND
STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES
OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NONINFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO
EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY
PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE,
SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION,
ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,
LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS,
LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS,
SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF
KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE
THIRD PARTY'S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER.
In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.
ibration or outdoors air. Components which wear
BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are
to be resold or delivered to a third party, Buyer must provide such third party with a copy
of this document, all specifications, manuals, catalogs, leaflets and written information
prov
ided to Buyer pertaining to the Products/Samples.
Page 16
Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.
234003E 1020-2a 96063E Printed in Japan
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.