KEYENCE LK-HA100 User Manual

96M00569
P OWER
S T ABILITY
BRIGHT
D ARK
HEAD
( V ) ( A ) ( A )
LK-HA100
LK-G5000 Series Head Expansion Unit
LK-HA100
Instruction Manual
Read this manual before use.
Keep this manual in a safe place for future reference.

Safety Precautions

General cautions

•At startup and during operation, be sure to monitor the functions and performance of the LK-HA100.
• It is recommended that you take substantial safety measures to avoid any damage in case of product failure.
• Do not modify the LK-HA100 or use it in any way other than as described in the specifications. The warranty will be voided in such cases.
• When the LK-HA100 is used in combination with other devices, functions and performance may be degraded depending on the operating conditions and surrounding environment.
• Do not use the LK-HA100 for the purpose of protecting the human body.
• Do not allow the temperature to change sharply around the LK-HA100 Series, including the accessories. Otherwise, condensation may lead to a malfunction.

Note on warnings and cautions

Read the LK-G5000 Series User’s Manual (pages 3 to 5) carefully.
(4) Terminal block
Used for analog monitor output.
OUT (V) Analog voltage output
OUT (A) Analog current output
OUT 0 V 0 V terminal for OUT
Outputs the displayed value as voltage within the range of ±10.5 V.
Outputs the displayed value as a current within the range of 3.6 mA to 20.4 mA.
The 6-pin terminal block of the controller corresponds to analog outputs CH01 and CH02. The terminal blocks of the head expansion units correspond to analog outputs CH03 to CH12 respectively from the controller side. For details about the analog output channel assignment, see "LK-G5000 Series User’s Manual".
(5) HEAD connector

Mounting the Controller

Caution on the orientation of the controller

Mount the controller only in the orientation shown with a circle in the following figures. Do not mount it upside down.
LK-HA100
P O
WER S T ABILITY
BRIGHT
D ARK
1
2 3 4
5 6
2
7
1 22
8
2
9
3 24
10
25
11
LASER ON
26
12
27
13
28
14
29
15
30 1 6
31
1 7
32
18
33
19
(
ETHERNET
V
LK-G5000
34
20
)
35
( A
36
)
37
( A
38
)
39
40
1
HEAD
LASER 1
LK-HD500
LO TIM
HI GO
OUT1
GO LO TIM
HI
K AR D
OUT2
ARK
HT
D
BRIG
BRIGHT
STABILITY
N
STABILITY
ZERO
LASER O
LASER ON
HEAD1 HEAD2
M A
ENT
R G
PRO
SET
SET
HEAD2
HEAD1
PROGRAM
LASER ON
OUT2
LASER ON
STABILITY
OUT1
STABILITY
HI
ENT
GO LO
BRIGHT
HI
BRIGHT
ZE RO
GO LO
DARK
DARK
TIM
TIM
LK-HD500
DC 24V
ENT
ZERO
DARK
DARK
BRIGHT
BRIGHT
TIM
TABILITY
TIM
S
LO
LK-HD500
PROGRAM
SET
LASER ON STABILITY
GO
LASER ON
LO
HI
HEAD2
GO
HEAD1
HI
OUT2
OUT1
(
COM IN
V
2
) ( A
O 1TIMIN
)
U
ZER
0V
S
B
(
G 1
V
) ( A
) 0V
2
GO
RS-232C
HEAD
D ISPL
AY
1
HEAD
ENT O ER
Z
K AR
D K R
DA
HT RIG
HT
B RIG B
M A
ILITY
R
B
SET
A
G
ITY
T
IL
O
S
R
AB
P
T
TIM
S
N O
R
N
SE
O
A
R
L SE LA
LO
2
D
1
EA
D
H
TIM
GO
EA H
LK-HD500
HI
LO
GO
OUT2
HI
OUT1

Checking the Package Contents

• Head expansion unit LK-HA100: 1
• User’s Manual: 1

Part Names and Functions

(1) POWER lamp
Lights when the power is on.
(2) Sensor head status indicator
Displays the laser emission status or the measurement status.
STABILITY Lights in green or orange when the
BRIGHT Lights when the excessive light
DARK Lights when the insufficient light
(3) Connector
result is within the measurement range. Lights in red when the result is outside the measurement range, when an alarm is issued, or when the laser is off.
intensity alarm is triggered.
intensity alarm is triggered.
LK-HA100
POWER
STABILITY
BRIGHT
DARK
HEAD
To secure the controller with the screws on the bottom
Provide clearance of 50 mm or more above, 30 mm or more on each side, and 30 mm or more at the rear of the controller for ventilation. In addition, for ensuring the
50 mm 50 mm
LK-G5000
LASER ON
1
21
2
22
(V)
3
23
4
24
(A)
1
5
25
6
26
0V
7
27
8
28
ETHERNET
(V)
9
29
10
30
(A)
2
11
31
12
32
0V
13
33
14
34
15
35
16
36
17
37
18
38
19
39
30
2
20
40
HEAD
USB
mm
COM INZERO 1TIMING 1GOLASER 1DC 24V
RS-232C
1
HEAD
DISPLAY
LK-HA100
POWER
STABILITY
BRIGHT
DARK
(V)
(A)
(A)
HEAD
30
mm
LK-G5000
LK-HA100
POWER
LASER ON
1
21
2
22
(V)
3
23
STABILITY
4
24
(A)
1
5
25
6
26
0V
BRIGHT
7
27
8
28
ETHERNET
(V)
9
29
10
30
DARK
(A)
2
11
31
12
32
0V
13
33
14
34
15
35
16
36
17
37
18
38
19
39
20
40
COM INZERO 1TIMING 1GOLASER 1DC 24V
30
2
HEAD
USB
(V)
(A)
mm
(A)
RS-232C
1
HEAD
HEAD
DISPLAY
safety of the cable connection work, provide 65 mm or more space in front of the terminal panel of the controller.
To mount the controller to the DIN rail
(1)
(2)
Provide clearance of 30 mm or more between the controllers, 50 mm or more above and 30 mm or more below the controller.
30
mm
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
COM INZERO 1TIMING 1GOLASER 1DC 24V
50 mm
LASER ON
21 22 23 24 25 26 27 28
ETHERNET
29 30 31 32 33 34 35 36 37 38 39 40
USB
RS-232C
DISPLAY
50 mm
LK-G5000
LK-HA100
POWER
(V)
STABILITY
(A)
1
0V
BRIGHT
(V)
DARK
(A)
2
0V
2
HEAD
(V)
(A)
(A)
1
HEAD
HEAD
30
mm
LK-G5000
LK-HA100
POWER
LASER ON
1
21
2
22
(V)
3
23
STABILITY
4
24
(A)
1
5
25
6
26
0V
BRIGHT
7
27
8
28
ETHERNET
(V)
9
29
10
30
DARK
(A)
2
11
31
12
32
0V
13
33
14
34
15
35
16
36
17
37
18
38
19
39
20
40
COM INZERO 1TIMING 1GOLASER 1DC 24V
30
2
HEAD
USB
(V)
(A)
mm
(A)
RS-232C
1
HEAD
HEAD
DISPLAY
(3)
(V)
(A)
(A)
(4)
CAUTION
•Do not block the ventilation holes on the top and bottom of the controller. The
(5)
heat may stay inside and cause a malfunction.
• When the temperature inside the control panel exceeds the specified ambient temperature (50°C when one or less head expansion unit is connected, 40°C when two or more head expansion units are connected), decrease the temperature of the controller bottom to the specified ambient temperature or lower by using forced air cooling or by providing more clearance arou nd the controller.
30 mm 30 mm

Connecting the head expansion unit

NOTE
26.3
1246
(65)
105.5
35.9
62.1
13.5
14
114
13.5
(65)
12826.3
1246
M4 Depth: 6
M4 Depth: 6
DIN rail
Specifications are subject to change without notice.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.
00569E 0049-1 96M00569 Printed in Japan
A6WW1-MAN-0019
CANADA
Phone: +1-905-696-9970
CHINA
Phone: +86-21-68757500
CZECH REPUBLIC
Phone: +420 222 191 483
GERMANY
Phone: +49-6102-36 89-0
FRANCE
Phone: +33 1 56 37 78 00
AUSTRIA
Phone: +43-2236-378266-0
HONG KONG
Phone: +852-3104-1010
BELGIUM
Phone: +32 2 716 40 63
ITALY
Phone: +39-2-6688220
JAPAN
Phone: +81-6-6379-2211
KOREA
Phone: +82-31-642-1270
MEXICO
Phone: +52-81-8220-7900
MALAYSIA
Phone: +60-3-2092-2211
NETHERLANDS
Phone: +31 40 20 66 100
HUNGARY
Phone: +36 14 748 313
POLAND
Phone: +48 71 36861 60
SINGAPORE
Phone: +65-6392-1011
SLOVAKIA
Phone: +421 2 5939 6461
SWITZERLAND
Phone: +41 43 455 77 30
THAILAND
Phone: +66-2-369-2777
TAI WA N
Phone: +886-2-2718-8700
UK & IRELAND
Phone: +44-1908-696900
USA
Phone: +1-201-930-0100
CAUTION
Turn off the power of the LK-HA100 before connecting the head expansion unit. Otherwise, you may suffer a shock or damage the unit.
1 Connect the head expansion
unit by aligning its connector to the connector on the left side of the controller.
Yo u need to remove the sticker attached to the left side of the controller beforehand.
2 Secure the head expansion
1 2 3
21
4
22
5
23
L
6
A
S
24
E
7
R O
25
8
N
LK-
26
9
G5000
27
10
28
11
29
12
30
13
E
31
14
T H
E
32
15
R
N E
1
33
16
T
OUT
34
17
( V )
35
18
OUT
36
19
( A )
37
20
OUT 0V
38
2
39
OUT
40
( V )
OUT
( A )
OUT 0V
USB
2
COM INZERO 1TIMING 1GOLASER 1DC 24V
H EA
D
RS-232
C
1
DIS
H
PLA
EA
Y
D
Connector
LK-HA
100
PO
W E
R
STA
B IL
IT
Y B R
IG H
T
D A
R
K
( V
) ( A
) ( A
)
H EAD
Screw position
unit by tightening the two fixing screws.
Tightening torque
Limit the tightening torque to
0.7 Nm or less.
1 2 3
21
4
22
5
23
L
6
A
S
24
E
7
R O
25
8
N
LK-
26
9
G5000
27
10
28
11
29
12
30
13
E
31
14
T H
E
32
15
R
LK-H
N E
1
33
16
T
OUT
34
17
A10
( V )
35
18
0
OUT
36
19
( A
PO
)
37
20
W
OUT 0V
E
38
R
2
39
OUT
S T
40
A
( V
B
)
ILIT
OUT
Y
( A )
B
OUT 0V
R
IG H
T
USB
D A
R
K
2
COM INZERO 1TIMING 1GOLASER 1DC 24V
HEAD
RS-232C
( V ) ( A )
1
DIS
( A )
HEAD
PL
A Y
HEAD
3 In the Environment settings,
specify the active head count and active OUT count.
See "LK-G5000 Series User’s Manual".
When you change the active head count or active OUT count in the Environment settings, all the settings of the LK-HA100 except for the Environment settings are reset. When you connect the LK-HA100 head expansion unit(s) and add a sensor head(s), be sure to set the active head count and active OUT count before changing the other measurement settings.
Screw position
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer's intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products.
(3) The Products and any samples (Products/Samples) supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.

Dimensions

BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by
Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/ Samples.
Loading...