HEIDENHAIN IOB 49 User Manual

User’s Manual
IOB 49
English (en) 3/2007

I Operating Instructions ..... 5

I General Information ..... 6
Connecting the IOB 49 to X10 for executing switching functions (milling) or controlling the constant surface speed
CSS (turning) ..... 6
Switching inputs ..... 7
Switching outputs ..... 7
I – 2 Controlling the Constant Surface Speed (CSS) ..... 10
Configuration of CSS ..... 11
CSS operating mode ..... 12
Activating the DAC output ..... 13
Connecting the IOB to the inverter of the lathe ..... 14
I – 3 Diagnostics ..... 15
Switching I/O functions ..... 15
CSS ..... 16
HEIDENHAIN IOB 49 3

Operating Instructions

HEIDENHAIN IOB 49 5

General Information

Connecting the IOB 49 to X10 for executing switching functions (milling) or controlling the constant surface speed CSS (turning)

When the IOB 49 is connected to the ND 780, the functionalities described above are available.
For information on the installation of the IOB 49 in an electrical cabinet, the connection technology and the wiring, please refer to the Operating Instructions. The Operating Instructions are included with every position display unit, or can be requested from HEIDENHAIN.
General Information
The position display unit automatically recognizes when an IOB 49 is connected and displays the CSS SETUP option or the SWITCHING OUTPUTS option in the INSTALLATION SETUP menu. These options can be used to configure all functions of the switching unit.
6 I Operating Instructions
I – 1 Execution of Switching
Functions
Switching functions can only be executed when the position display unit is configured for milling applications.
If you want to use both the IOB 49 and the KT 130 edge finder at the same time or if you want to transmit measured values via the external switching output, the distribution cable with ID 532 909-01 is required.

Switching inputs

The IOB 49 provides three inputs that are used to zero the actual value of the assigned axis. A low-to-high transition at the input causes the value for that axis to be set to zero.

Switching outputs

The switching outputs consist of eight (integrated) relays that are activated depending on the position. The relays can be configured to activate when a position display reaches a specific value or within a specified range of zero. The ninth output relay indicates readiness.
Select SWITCHING OUTPUTS from the INSTALLATION SETUP menu to open the SWITCHING OUTPUTS table in which the configuration of the eight outputs is stored. If you want to change the configuration of an output, select it with the arrow keys and press ENTER to confirm your selection. This opens the OUTPUT SETTINGS form in which you define the switching conditions. To reset a relay, select the relay in the table and press the CLEAR RELAY soft key.
I – 1 Execution of Switching Functions
Fig. I.1
HEIDENHAIN IOB 49 7