Parts and Functions

1

Safety ................................................................................................................................................................................

2

Maintenance

4

Fault Checkup ...................................................................................................................................................................

6

Installation Procedures

7

Electrical Wiring...............................................................................................................................................................

12

Test Run & Fault Code ....................................................................................................................................................

17

Your air conditioner may be subject to any change owing to the improvement of Haier products.

MRV series multiple air conditioning systems adopt the consistent running mode, by which, all indoor units can only be heating or refrigerating operation at the same time.

To protect the compressor, the air conditioning unit should be powered on for over 12 hours before using it.

All indoor units of the same refrigerating system should use the unified power switch to ensure that all indoor units are in the state of being powered on at the same time during the operation of air conditioner.

Product Features:

1.Hanging-style installation to save space; 2.Automatic display of faults;

3.Central control function; (optional from our company).

4.If there is a power outage while the system is operating, the system will resume the last mode and settings it was set to run in.

5.This indoor unit ships with wireless controller. It is compatible with both YR-E17 and YR-E16 wired controllers.

Warning

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

•  This equipment should not be used or serviced by personnel who have not been properly trained in its operation and maintenance.

•  Children should be supervised to ensure that they do not play with the appliance.

•  The appliances are not intended to be operated by means of an external timer or separate remote-control system. •  Keep the appliance and its cord out of reach of children.

Operation condition:

To use the air conditioner normally, please perform as to the below conditions.

Operating Range of Air Conditioner

 

Indoor

Max.

DB: 90°F(32°C)

WB: 74°F(23°C)

Cooling

Min.

DB: 64°F(18°C)

WB: 57°F(14°C)

 

dry

Outdoor

Max.

DB: 115°F(46°C)

WB: 79°F(26°C)

 

 

Min.

DB: 23°F(-5°C)

 

 

 

 

 

Indoor

Max.

DB: 80°F(27°C)

 

Heating

Min.

DB: 59°F(15°C)

 

 

 

Outdoor

Max.

DB: 75°F(24°C)

WB: 59°F(15°C)

 

 

Min.

DB: -4°F(-20°C)

 

 

 

 

Parts and Functions

Indoor unit

Outlet guide plate (air direction can be adjusted by using direction adjustment key on the remote controller)

Air-inlet grille

Air filter (inside air-inlet grille)

1

Safety

•  This manual should be saved and stored close to this air conditioning equipment.

•  There are two types if indications. Both are related to safety and should be strictly followed. "Warning" highlights issues that pose a risk of major injury or death. " Caution" highlights issues that pose a risk of equipment or bodily injury.

•  After installation and start-up commissioning, please give the manual to the user. The manual should be kept in safe place and close to the unit.

WARNING

•  Installation and maintenance should be performed by an authorized agency. The wrong operation of this air condition equipment may cause water damage, electric shock or fire.

•  Please install the unit on the top of a solid foundation or structure which is strong enough to support the unit. •  The installation of this condition equipment should follow local building codes.

•  Use the right cable size, secure the terminal firmly, organize the cables well and make sure no tension is added on cables. Cable insulation should not be damaged. Improper wire installation may lead to fire.

•  This unit is only compatible with R-410A refrigerant. If any other gas enters the system, it may lead to abnormal high pressure which may cause damage or injury.

•  Only use branches supplied by Haier. Use of any other branches will void warranty.

•  Keep the condensate drain pipe away from toxic gas vents to prevent possible pollution of indoor environment.

•  Care should be taken to ensure that there are no refrigerant leaks. R-410A is a heavy gas and will displace oxygen. Ventilate the area if a leak if found.

•  The unit is not explosion-proof. Please keep it away from flammable gases.

•  The drain pipe should be installed per this manual to ensure proper drainage. The pipe should be well insulated to avoid condensation. Wrong installation may lead to water damage.

•  Both liquid pipe and the vapor pipe should be also well insulated. Not enough insulation may lead to system performance deterioration or condensate formation.

•  This equipment should not be used or serviced by personnel who have not been properly trained in its operation and maintenance.

•  Children should be supervised to ensure that they do not play on or near the equipment. •  Keep the appliance and its cord out of reach of children.

•  The appliances are not intended to be operated by means of an external timer or separate remote-control system.

CAUTION

•  Grounding wire should be connected to the grounding bar. The grounding wire cannot be connected to the gas pipe, water pipe, lightening rod or the telephone grounding wire. Improper grounding may cause electric shock.

•  A circuit breaker should be installed. If not, it may cause electric shocks or accidents.

•  After installation, the air condition equipment should be powered on and passed the electric leakage current lest.

•  If the ambient humidity is more than 80%, if the water discharge hole is blocked or the filter becomes dirty or the airflow speed changes, this may lead to condensate water leaks. There may also be some drops of water spraying out.

2

Haier MVAL048MV2AA, MVAL042MV2AA, MVAL036MV2AA, MVAL030MV2AA, MVAL024MV2AA Owner’s Manual

Safety

Notices during Operation

Attention

•  Do not put any heating apparatus under the

•  3-minutes protection

indoor units. The heat may cause distortion of the

To protect the unit, there is a 3-minute time-out after

units.

the unit stops or after power is applied.

•  Pay attention to the ventilation to avoid anoxic injury.

•  Close the window to avoid outdoor air getting in.

 

Curtains or window shutters can be put down to avoid

 

the sunshine.

•  Do not place an open flame in the path of blowing air.

•  Do not touch the power switch with the wet hand to

 

avoid power shock.

•  Do not install in a corrosive environment. If the base

•  Turn off the system and remove power when servicing

collapses, the unit may fall and cause damage,

the unit.

product failure, personal injury or death.

 

•  Do not use the unit for special purposes such

•  Don't remove power while system is running.

as preserving foods, works of art etc. It is an air

 

conditioner for comfort cooling / heating, not a

 

precision refrigeration system.

 

•  Use the correctly rated breaker or fuse. Improper

•  Do not clean the unit with water spray. There is risk

breaker or fuse may lead to fire, electric shock,

of unit failure, fire, electric shock, personal injury or

explosion, personal injury or death.

death.

•  Do not permit water or steam to enter the unit and

•  Keep flammable gas or combustibles away from the

the wired controller. There is risk of unit failure, fire,

unit. There is risk of product failure, fire, personal

electric shock, personal injury or death.

injury or death.

•  Turn off the power to save energy if the unit will

•  Please keep children away from this air condition

be not used for a long period. If the unit is not

equipment.

powered off, it will consume power.

 

3

Maintenance

Attention

•  Repair can only be performed by licensed service technicians.

•  Before touching the electrical connections, all power supplies should be turned off. Only after switching off the power supply can the operator clean the air conditioner otherwise there is a risk of electric shock or injury.

•  When cleaning the air cleaner, make sure to use a stable platform; don't flush the air conditioner with water, or electric shock might occur.

Filter Maintenance:

Clean the air filter & air inlet grid.

•  Don't remove the air filter except for cleaning, or faults may occur.

•  When the air conditioner operates in the environment with too much dust, clean the air conditioner more times (generally once every two weeks).

1.Remove the air inlet grid as shown below: press on the two locks on the grid (as shown in Fig. 1), gently lift it at a 45 degree angle (as shown in Fig. 2), and then remove the air inlet grid.

2.Dismantle the filter: press the outer frame of the air inlet grid, and draw the base angle of the filter pull it out as to disengage the locks, and remove the filter (as shown in Fig. 3).

press down the locks

 

locks

hinge

bottom of gauze

 

 

lock port

 

 

 

hinges

 

remove air inlet grid

frame of air inlet grid

 

 

Fig. 1

Fig. 2

Fig. 3

Cleaning Air Cleaner

Clean the air filter with a vacuum or water to remove dust.

For heavy dust, use the vacuum or directly spray mild soap on the air inlet grid, and then clean it with water after soaking for ~10 minutes.

(A)remove dust with dust collector.

(B)for heavy dust, use a soft brush and mild detergent to clean.

(C)rinse off water/soap and dry in a cool place.

Attention

•  Do not clean it with hot water 122°F(50°C) to avoid fading or distortion.