Haier HWF05XC7 Service Manual

5 (3)
Haier HWF05XC7 Service Manual

Haier air conditioner

Edition: 1.0-061231

Domestic air conditioner

SERVICE MANUAL

Model

HWF05XC7

Feature

Top Discharge Airflow Pattern

Modern Family-look Design

Safety Power Cord

2 Cool Settings,2 Fan Settings

Mechanical Control

- 1 -

Haier air conditioner

Edition: 1.0-061231

 

 

Content

1.

Product Code Illumination and Series introduction

...........................3

2.

Specifications....................................................................................

4

3.

Safety and Precaution.......................................................................

5

4.

Warning and Cautions.......................................................................

6

5.

Installation and Accessory Parts........................................................

7

6.

Parts and Functions.........................................................................

12

7. Abnormity Diagnose.........................................................................

13

8.

System Flow Chart...........................................................................

14

9. Wiring Diagram................................................................................

15

- 2 -

Haier air conditioner

Edition: 1.0-061231

 

 

1. Product Code Illumination and Series introduction

1). Model identification:

H W □ □□ □ □ □

A B C D E F G

A:Abbreviation of Haier

B:Abbreviation of Window

C:R - Remote Control

F - Mechanical Control

D:Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit

E:The type of power supply

X - 115V / 60HZ

V - 230V/208V / 60HZ

F:Function code

C - Cooling only

H - Heating pump or Electric heater

G: Design code

ESA □□ □

A B C

A:Abbreviation of Energy Star

B:Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit

C:Design code

Examples:

HWF05XC7

It represents mechanical control window air conditioner. Cooling capacity is 5200BTU/h and the power supply is 115V / 60Hz.

2). Standard situation/conditions

No.

Operating condition

Indoor air state

outdoor air state

D.B.

W.B.

D.B.

W.B.

 

 

1

Nominal cooling

26.7

19.4

35

23.9

2

Nominal heating

/

/

/

/

3

Nominal electrical Heating

/

/

/

/

- 3 -

Haier air conditioner

Edition: 1.0-061231

 

 

2. Specification

 

 

Item

Unit

HWF05XC7

 

 

 

 

 

Cooling capacity

 

BTU/h

5200

 

 

 

 

 

 

Heating capacity

 

BTU/h

 

/

 

 

 

 

 

Power supply

 

Ph, V, Hz

1, 115, 60

 

 

 

 

 

 

 

 

Power input

W

 

535

Cooling

 

 

 

 

Running current

A

 

4.8

 

 

 

 

 

 

 

 

EER

BTU/(h·W)

 

9.7

 

 

 

 

 

 

 

 

Power input

W

 

/

Heating

 

 

 

 

Running current

A

 

/

 

 

 

 

 

 

 

 

COP

BTU/(h·W)

 

/

 

 

 

 

 

 

Sound Level

Indoor side

dB(A)

 

51

 

 

 

 

Outdoor side

dB(A)

 

62

 

 

 

 

 

 

 

 

 

 

 

Height

inches

11

5/32

Case

Width

inches

17

9/32

 

 

 

 

 

 

 

 

Depth

inches

7

9/32

Packaging

Height

inches

12 25/32

 

 

 

 

Width

inches

19 11/16

dimensions

Depth

inches

14 15/16

 

 

 

 

 

 

 

 

Weight

Net

lbs

 

38.6

 

 

 

 

Gross

lbs

 

44.0

 

 

 

 

 

 

 

 

 

 

Type

 

Rotary

Compressor

 

 

 

Model

/

YZG-A15CD2

 

 

 

 

 

 

 

Running cap. For comp.

μF

40μF/250 V

 

 

 

 

 

 

Pressure

Hi-Pressure

Psig

 

380

 

 

 

 

Low-Pressure

Psig

 

170

 

 

 

 

 

 

 

 

 

Refrigerant

Model

R22 or R410A

 

R22

 

 

 

 

Charge

OZ

 

10.6

 

 

 

 

 

 

 

 

 

Type

Indoor unit

/

centrifugal

 

 

 

 

 

Fan

Outdoor unit

/

 

axial

 

 

 

 

 

 

 

 

Fan Speed

Indoor unit

r/min

1110±30

 

 

 

 

 

 

 

 

 

 

Air volume

 

CFM

 

135

 

 

 

 

 

Moisture removal

 

Pints/hr

 

/

 

 

 

 

 

 

- 4 -

Haier air conditioner

Edition: 1.0-061231

 

 

3. Safety and Precaution

WARNING: Following these basic precautions will reduce the risk of

fire, electrical shock, injury or death when using your air

conditioner.

1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. (See table)

2) Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG.

If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded.

3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion damage along the length, plug or connector.

4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD.

5) When installing your air conditioner in a window, make sure the window is strong enough to hold the weight of he air conditioner. You also want to secure and correctly install your air conditioner property to prevent it from falling. Extra brackets or support may be required depending on your window.

6)Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers, shrubs or bushes.

7)Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury.

8)Be careful when lifting the air conditioner to install or remove the unit. Always use two or more people for this.

9)Always unplug the air conditioner before servicing it or moving it.

- 5 -