Haier air conditioner |
Edition: 1.0-061231 |
Domestic air conditioner
SERVICE MANUAL
Model
HWF05XC7
Feature
Top Discharge Airflow Pattern
Modern Family-look Design
Safety Power Cord
2 Cool Settings,2 Fan Settings
Mechanical Control
- 1 -
Haier air conditioner |
Edition: 1.0-061231 |
|
|
Content
1. |
Product Code Illumination and Series introduction |
...........................3 |
2. |
Specifications.................................................................................... |
4 |
3. |
Safety and Precaution....................................................................... |
5 |
4. |
Warning and Cautions....................................................................... |
6 |
5. |
Installation and Accessory Parts........................................................ |
7 |
6. |
Parts and Functions......................................................................... |
12 |
7. Abnormity Diagnose......................................................................... |
13 |
|
8. |
System Flow Chart........................................................................... |
14 |
9. Wiring Diagram................................................................................ |
15 |
- 2 -
Haier air conditioner |
Edition: 1.0-061231 |
|
|
1. Product Code Illumination and Series introduction
1). Model identification:
H W □ □□ □ □ □
A B C D E F G
A:Abbreviation of Haier
B:Abbreviation of Window
C:R - Remote Control
F - Mechanical Control
D:Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit
E:The type of power supply
X - 115V / 60HZ
V - 230V/208V / 60HZ
F:Function code
C - Cooling only
H - Heating pump or Electric heater
G: Design code
ESA □ □□ □
A B C
A:Abbreviation of Energy Star
B:Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit
C:Design code
Examples:
HWF05XC7
It represents mechanical control window air conditioner. Cooling capacity is 5200BTU/h and the power supply is 115V / 60Hz.
2). Standard situation/conditions
No. |
Operating condition |
Indoor air state |
outdoor air state |
|||
D.B. |
W.B. |
D.B. |
W.B. |
|||
|
|
|||||
1 |
Nominal cooling |
26.7 |
19.4 |
35 |
23.9 |
|
2 |
Nominal heating |
/ |
/ |
/ |
/ |
|
3 |
Nominal electrical Heating |
/ |
/ |
/ |
/ |
- 3 -
Haier air conditioner |
Edition: 1.0-061231 |
|
|
2. Specification
|
|
Item |
Unit |
HWF05XC7 |
||
|
|
|
|
|
||
Cooling capacity |
|
BTU/h |
5200 |
|||
|
|
|
|
|
|
|
Heating capacity |
|
BTU/h |
|
/ |
||
|
|
|
|
|
||
Power supply |
|
Ph, V, Hz |
1, 115, 60 |
|||
|
|
|
|
|
|
|
|
|
Power input |
W |
|
535 |
|
Cooling |
|
|
|
|
||
Running current |
A |
|
4.8 |
|||
|
|
|
|
|
|
|
|
|
EER |
BTU/(h·W) |
|
9.7 |
|
|
|
|
|
|
|
|
|
|
Power input |
W |
|
/ |
|
Heating |
|
|
|
|
||
Running current |
A |
|
/ |
|||
|
|
|
|
|
|
|
|
|
COP |
BTU/(h·W) |
|
/ |
|
|
|
|
|
|
|
|
Sound Level |
Indoor side |
dB(A) |
|
51 |
||
|
|
|
|
|||
Outdoor side |
dB(A) |
|
62 |
|||
|
|
|
||||
|
|
|
|
|
|
|
|
|
Height |
inches |
11 |
5/32 |
|
Case |
Width |
inches |
17 |
9/32 |
||
|
|
|
|
|
|
|
|
|
Depth |
inches |
7 |
9/32 |
|
Packaging |
Height |
inches |
12 25/32 |
|||
|
|
|
|
|||
Width |
inches |
19 11/16 |
||||
dimensions |
||||||
Depth |
inches |
14 15/16 |
||||
|
|
|||||
|
|
|
|
|
|
|
Weight |
Net |
lbs |
|
38.6 |
||
|
|
|
|
|||
Gross |
lbs |
|
44.0 |
|||
|
|
|
||||
|
|
|
|
|
||
|
|
Type |
|
Rotary |
||
Compressor |
|
|
|
|||
Model |
/ |
YZG-A15CD2 |
||||
|
|
|
|
|
||
|
|
Running cap. For comp. |
μF |
40μF/250 V |
||
|
|
|
|
|
|
|
Pressure |
Hi-Pressure |
Psig |
|
380 |
||
|
|
|
|
|||
Low-Pressure |
Psig |
|
170 |
|||
|
|
|
||||
|
|
|
|
|
|
|
Refrigerant |
Model |
R22 or R410A |
|
R22 |
||
|
|
|
|
|||
Charge |
OZ |
|
10.6 |
|||
|
|
|
||||
|
|
|
|
|
||
|
Type |
Indoor unit |
/ |
centrifugal |
||
|
|
|
|
|
||
Fan |
Outdoor unit |
/ |
|
axial |
||
|
|
|||||
|
|
|
|
|
||
|
Fan Speed |
Indoor unit |
r/min |
1110±30 |
||
|
|
|
|
|||
|
|
|
|
|
|
|
Air volume |
|
CFM |
|
135 |
||
|
|
|
|
|
||
Moisture removal |
|
Pints/hr |
|
/ |
||
|
|
|
|
|
|
- 4 -
Haier air conditioner |
Edition: 1.0-061231 |
|
|
3. Safety and Precaution
WARNING: Following these basic precautions will reduce the risk of
fire, electrical shock, injury or death when using your air
conditioner.
1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. (See table)
2) Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG.
If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded.
3) DO not use if power cord is frayed or damage. Also avoid using if there are cracks or abrasion damage along the length, plug or connector.
4) DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
5) When installing your air conditioner in a window, make sure the window is strong enough to hold the weight of he air conditioner. You also want to secure and correctly install your air conditioner property to prevent it from falling. Extra brackets or support may be required depending on your window.
6)Do not black airflow inside or outside the air conditioner with blinds, drapes, protective covers, shrubs or bushes.
7)Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury.
8)Be careful when lifting the air conditioner to install or remove the unit. Always use two or more people for this.
9)Always unplug the air conditioner before servicing it or moving it.
- 5 -