SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . 3 REFRIGERANT SYSTEM DIAGRAM . . . . . . . . 5 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 6 DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . 7 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 STANDARD ACCESSORIES . . . . . . . . . . . . . . . . 14
SPECIFICATIONS
TYPE |
|
|
|
COOLING & HEATING |
COOLING & HEATING |
INDOOR UNIT |
|
|
|
ASH9USBCW |
ASH12USBCW |
OUTDOOR UNIT |
|
|
AOH9UGBC |
AOH12UGBC |
|
COOLING CAPACITY |
(kW) |
2.90 |
3.70 |
||
HEATING CAPACITY |
(kW) |
3.05 |
4.00 |
||
ELECTRICAL DATA |
|
|
|
|
|
POWER SOURCE |
|
|
230V 50Hz |
230V 50Hz |
|
RUNNING CURRENT (A) |
COOL |
3.7 |
5.0 |
||
|
|
|
HEAT |
3.3 |
4.6 |
INPUT WATTS |
(kW) |
COOL |
0.84 |
1.13 |
|
|
|
|
HEAT |
0.75 |
1.04 |
E.E.R |
(kW/kW) |
COOL |
3.45 |
3.27 |
|
|
|
|
HEAT |
4.07 |
3.85 |
MOISTURE REMOVAL |
( /hr) |
1.3 |
1.9 |
||
AIR CIRCULATION-Hi |
(m3/hr) |
COOL 600 HEAT 600 |
COOL 700 HEAT 675 |
||
COMPRESSOR |
|
|
|
|
|
TYPE |
|
|
|
Hermetic type, Permanent split condenser, 2 pole, Single phase, Induction motor |
|
CODE |
|
|
|
GK113PAC 220, 230, 240V / 50Hz |
GK151PAB 220-240V / 50Hz |
REFRIGERANT |
R410A |
(g) |
900 |
970 |
FAN MOTOR
POWER SUPPLY Hi-SPEED
INDOOR MED-SPEED UNIT
(r.p.m) LO-SPEED S-LO
OUTDOOR UNIT
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
INDOOR UNIT
OUTDOOR UNIT
NOISE LEVEL
Hi-SPEED
INDOOR MED-SPEED UNIT
(dB) |
LO-SPEED |
|
S-LO |
||
|
||
OUTDOOR UNIT |
(V)
(r.p.m)
H x W x D (mm)
GROSS /
NET(kg)
(dB)
230 |
|
|
COOL 1250 |
HEAT |
1250 |
COOL 1100 |
HEAT |
1120 |
COOL 950 |
HEAT 990 |
|
COOL 800 |
HEAT 860 |
|
730 |
|
|
275 x 790 x 215 |
|
|
535 x 695 x 250 |
|
|
12 / 9 |
|
|
33 / 30 |
|
|
COOL 40 |
HEAT |
39 |
COOL 36 |
HEAT |
35 |
COOL 32 |
HEAT |
31 |
COOL 27 |
HEAT |
26 |
COOL 45 |
HEAT |
46 |
230
COOL 1450 HEAT 1400 COOL 1250 HEAT 1230 COOL 1050 HEAT 1060 COOL 850 HEAT 900 820
275 x 790 x 215
535 x 780 x 250
12 / 9
37 / 35
COOL 45 HEAT 43 COOL 41 HEAT 39 COOL 35 HEAT 34 COOL 29 HEAT 28 COOL 48 HEAT 49
2003.09.30 |
1 |
ADDIT ION AL CHAR G E OF R E FR IG E R AN T |
(R 410A) |
|
|
|||
(AS H9U S B CW / AOH9U G B C) |
|
|
|
|
||
(AS H12U S B CW / AOH12U G B C) |
|
|
|
|
||
R efrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory. |
|
|||||
W hen the piping is longer than 7.5 m, additional charging is necessary. |
|
|
||||
For the additional amount, see the table below. |
|
|
|
|
||
|
|
|
|
|
|
|
|
PIPE LENG TH |
|
7.5 m |
|
10 m |
15 m |
|
|
|
|
|
|
|
|
ADDITIONAL R EFR IG ER ANT |
|
None |
|
50 g |
150 g |
|
|
|
|
|
|
|
Between 7.5 m and 15 m, when using a connection pipe other than that in the table, charge additional refrigerant with 20g /1 m as the criteria.
(The maximum length of piping is 15m. If the units are further apart than this, correct operation can not be guaranteed.)
2003.09.30 |
2 |
|
|
|
D I M E N S I O N S |
|
|
INDOOR UNIT |
|
|
U nit : mm |
||
(ASH9USBCW / ASH12USBCW) |
|
|
|
||
|
|
|
790 |
|
215 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
275
OUTDOOR UNIT
(AOH9UGBC)
290
|
440 |
Drain pipe hold O20 |
|
54 |
|
|
265 |
500 |
98 |
695 |
|
535
13
250 |
2003.04.25 |
3 |
(AOH12UGBC)
302 |
272 |
|
540 |
120 |
|
780 |
55 |
250 |
535 |
|
|
10 |
|
|
2003.04.25 |
4 |
R E F R I G E R A N T S Y S T E M D I A G R A M
Models : ASH9USBCW / AOH9UGBC
ASH12USBCW / AOH12UGBC
[ INDOOR UNIT ] |
Evaporator |
[ Connecting pipe ] |
(Flare connection) |
(Flare connection) |
Gas pipe (9.52 dia.) |
Liquid pipe (6.35 dia.) |
|
|
(Flare connection) |
(Flare connection) |
[ OUTDOOR UNIT ] |
3-Way valve |
|
|
2-Way valve |
|
|
(with Charging valve) |
|
|
Dryer |
|
4-Way |
|
|
valve |
|
|
Check
Com- Condenser valve pressor
Capillary tube
for heating and cooling
Capillary tube for heating
Cooling
Heating
2003.04.25 |
5 |