General ASH12RJ, ASH12RSJCW, AOH12RSJC, ASH9RJ, ASH9RSJCW Service Manual

...
0 (0)

SPLIT TYPE ROOM AIR CONDITIONER

WALL MOUNTED type

Models Indoor unit

Outdoor unit

ASH9RSJCW

AOH9RSJC

ASH12RSJCW

AOH12RSJC

C O N T E N T S

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 5 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CONTROLLER PCB ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . 7 ERROR DISPLAY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 STANDARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

S P E C I F I C A T I O N S

TYPE

 

COOLING & HEATING

COOLING & HEATING

 

 

 

 

 

IN

ASH9RSJCW

ASH12RSJCW

MODEL

 

 

 

OUT

AOH9RSJC

AOH12RSJC

 

 

 

 

 

COOLING CAPACITY

kW

2.50

3.25

HEATING CAPACITY

kW

2.95

3.80

 

 

 

 

ELECTRICAL DATA

POWER SOURCE

 

 

230V 50Hz

 

230V 50Hz

 

 

 

 

 

 

 

 

 

 

RUNNING CURRENT

(A)

COOL

4.8

 

6.2

 

 

 

 

HEAT

4.3

 

5.7

 

 

 

 

 

 

 

 

 

 

 

INPUT WATTS

(kW)

COOL

1.00

 

1.31

 

 

 

 

HEAT

0.86

 

1.22

 

 

 

 

 

 

 

 

 

 

 

E.E.R.

(kW/kW)

 

COOL

2.50

 

2.48

 

 

 

 

 

 

HEAT

3.43

 

3.11

 

 

 

 

 

 

 

 

 

 

MOISTURE REMOVAL

 

/h

1.3

 

1.8

 

 

 

 

 

 

AIR CIRCULATION-Hi

 

(m3/hr)

COOL 540 HEAT 515

 

COOL 535 HEAT 545

COMPRESSOR

TYPE

 

Hermetic type, Permanet split condenser, 2 pole, Single phase, Induction motor

 

 

 

 

 

 

CODE

 

80603745

220,230,240V/50Hz

80679045Z,80679045N

220,230,240V/50Hz

 

 

 

 

 

 

REFRIGERANT R-22

(g)

650

 

 

770

 

 

 

 

 

 

FAN MOTOR

POWER SUPPLY

 

(V)

 

 

230

 

 

 

230

 

 

HI-SPEED

(r.p.m.)

COOL

1310

HEAT

1250

COOL

1310

HEAT

1330

 

 

 

 

 

 

 

 

 

 

 

INDOOR UNIT

MED-SPEED

(r.p.m.)

COOL

1170

HEAT

1140

COOL

1200

HEAT

1210

 

 

 

 

 

 

 

 

 

 

LO-SPEED

(r.p.m.)

COOL

1030

HEAT

1020

COOL

1090

HEAT

1090

 

 

 

 

 

 

 

 

 

 

 

 

 

QUIET

(r.p.m.)

COOL

900

HEAT

900

COOL

980

HEAT

980

OUTDOOR UNIT

 

(r.p.m.)

 

 

800

 

 

 

770

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

INDOOR UNIT

 

257 x 808 x 187

257 x 808 x 187

OUTDOOR UNIT H x W x D

(mm)

 

 

535 x 650 x 250

535 x 695 x 250

WEIGHT

INDOOR UNIT

10 / 8

10 / 8

OUTDOOR UNIT NET / GROSS (kg)

 

 

28 / 25

34 / 31

NOISE LEVEL

 

HI-SPEED

(dB)

COOL

39

HEAT

37

COOL

40

HEAT

40

 

 

 

 

 

 

 

 

 

 

 

INDOOR UNIT

MED-SPEED

(dB)

COOL

35

HEAT

34

COOL

39

HEAT

39

LO-SPEED

(dB)

COOL

33

HEAT

31

COOL

37

HEAT

37

 

 

 

 

 

 

 

 

 

 

 

 

SUPER QUIET (dB)

COOL

29

HEAT

27

COOL

34

HEAT

34

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

(dB)

COOL

46

HEAT

46

COOL

47

HEAT

48

2003.07.04

- 1 -

ADDITIONAL CHARGE OF REFRIGERANT

Refrigerant suitable for a piping length of 7.5m is charged in the outdoor unit at the factory.

When the piping is longer than 7.5m, additional charging is necessary. For the additional amount, see the table below.

ASH9RSJCW /AOH9RSJC

Pipe

7.5m

10m

length

 

 

 

 

 

Additional

None

40g

refrigerant

 

 

 

 

 

Between 7.5m and 10m, when using a connection pipe other than that in the table, charge additional refrigerant with 16g/1m as the criteria.

(The maximum length of the piping is 10m. If the units are further apart than this, correct operation can not be guaranteed.)

ASH12RSJCW / AOH12RSJC

Pipe

7.5m

10m

15m

length

 

 

 

 

 

 

 

Additional

None

40g

120g

refrigerant

 

 

 

 

 

 

 

Between 7.5m and 15m, when using a connection pipe other than that in the table, charge additional refrigerant with 16g/1m as the criteria.

(The maximum length of the piping is 15m. If the units are further apart than this, correct operation can not be guaranteed.)

2003.07.04

- 2 -

D I M E N S I O N S

INDOOR UNIT

Models : ASH9RSJCW

ASH12RSJCW

U nit : mm

808

 

 

187

 

 

 

 

 

 

 

 

257

2003.04.22

- 3 -

General ASH12RJ, ASH12RSJCW, AOH12RSJC, ASH9RJ, ASH9RSJCW Service Manual

OUTDOOR UNIT

Model : AOH9RSJC

Model : AOH12RSJC

290

2003.04.22

250

650

535

 

440

Drain pipe hold O20

54

 

 

265

500

98

695

 

535

13

- 4 -

U nit : mm

250

R E F R I G E R A N T S Y S T E M D I A G R A M

Model : ASH9RSJCW / AOH9RSJC

INDOOR UNIT

 

 

OUTDOOR UNIT

 

 

Capillary tube

Capillary tube

Refrigerant pipe

Strainer

for heating

for heating and cooling

6.35mm(1/4")

2-Way

Check valve

 

 

valve

 

 

 

 

Compressor

Evaporator

Condenser

4-Way valve

Refrigerant pipe

9.52mm(3/8")

Charging valve

3-Way

valve

 

Models : ASH12RSJCW / AOH12RSJC

INDOOR UNIT

 

 

OUTDOOR UNIT

 

 

Capillary tube

Capillary tube

Refrigerant pipe

Strainer

for heating

for heating and cooling

6.35mm(1/4")

2-Way

Check valve

 

 

valve

 

 

 

 

Compressor

Evaporator

Condenser

4-Way valve

Refrigerant pipe 12.7mm(1/2")

Charging valve

3-Way

valve

 

Cooling

Heating

: Flare coupling

2003.07.04

- 5 -

Loading...
+ 11 hidden pages