SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . 3 REFRIGERANT SYSTEM DIAGRAM . . . . . . . . 5 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 6 DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . 7 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 STANDARD ACCESSORIES . . . . . . . . . . . . . . . . 14

General ASH12UB, ASH12USBCW, AOH12UGBC, ASH9UB, ASH9USBCW Service Manual

SPECIFICATIONS

TYPE

 

 

 

COOLING & HEATING

COOLING & HEATING

INDOOR UNIT

 

 

 

ASH9USBCW

ASH12USBCW

OUTDOOR UNIT

 

 

AOH9UGBC

AOH12UGBC

COOLING CAPACITY

(kW)

2.90

3.70

HEATING CAPACITY

(kW)

3.05

4.00

ELECTRICAL DATA

 

 

 

 

POWER SOURCE

 

 

230V 50Hz

230V 50Hz

RUNNING CURRENT (A)

COOL

3.7

5.0

 

 

 

HEAT

3.3

4.6

INPUT WATTS

(kW)

COOL

0.84

1.13

 

 

 

HEAT

0.75

1.04

E.E.R

(kW/kW)

COOL

3.45

3.27

 

 

 

HEAT

4.07

3.85

MOISTURE REMOVAL

( /hr)

1.3

1.9

AIR CIRCULATION-Hi

(m3/hr)

COOL 600 HEAT 600

COOL 700 HEAT 675

COMPRESSOR

 

 

 

 

 

TYPE

 

 

 

Hermetic type, Permanent split condenser, 2 pole, Single phase, Induction motor

CODE

 

 

 

GK113PAC 220, 230, 240V / 50Hz

GK151PAB 220-240V / 50Hz

REFRIGERANT

R410A

(g)

900

970

FAN MOTOR

POWER SUPPLY Hi-SPEED

INDOOR MED-SPEED UNIT

(r.p.m) LO-SPEED S-LO

OUTDOOR UNIT

DIMENSIONS

INDOOR UNIT

OUTDOOR UNIT

WEIGHT

INDOOR UNIT

OUTDOOR UNIT

NOISE LEVEL

Hi-SPEED

INDOOR MED-SPEED UNIT

(dB)

LO-SPEED

S-LO

 

OUTDOOR UNIT

(V)

(r.p.m)

H x W x D (mm)

GROSS /

NET(kg)

(dB)

230

 

 

COOL 1250

HEAT

1250

COOL 1100

HEAT

1120

COOL 950

HEAT 990

COOL 800

HEAT 860

730

 

 

275 x 790 x 215

 

535 x 695 x 250

 

12 / 9

 

33 / 30

 

COOL 40

HEAT

39

COOL 36

HEAT

35

COOL 32

HEAT

31

COOL 27

HEAT

26

COOL 45

HEAT

46

230

COOL 1450 HEAT 1400 COOL 1250 HEAT 1230 COOL 1050 HEAT 1060 COOL 850 HEAT 900 820

275 x 790 x 215

535 x 780 x 250

12 / 9

37 / 35

COOL 45 HEAT 43 COOL 41 HEAT 39 COOL 35 HEAT 34 COOL 29 HEAT 28 COOL 48 HEAT 49

2003.09.30

1

ADDIT ION AL CHAR G E OF R E FR IG E R AN T

(R 410A)

 

 

(AS H9U S B CW / AOH9U G B C)

 

 

 

 

(AS H12U S B CW / AOH12U G B C)

 

 

 

 

R efrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory.

 

W hen the piping is longer than 7.5 m, additional charging is necessary.

 

 

For the additional amount, see the table below.

 

 

 

 

 

 

 

 

 

 

 

 

PIPE LENG TH

 

7.5 m

 

10 m

15 m

 

 

 

 

 

 

 

 

ADDITIONAL R EFR IG ER ANT

 

None

 

50 g

150 g

 

 

 

 

 

 

 

Between 7.5 m and 15 m, when using a connection pipe other than that in the table, charge additional refrigerant with 20g /1 m as the criteria.

(The maximum length of piping is 15m. If the units are further apart than this, correct operation can not be guaranteed.)

2003.09.30

2

 

 

 

D I M E N S I O N S

 

INDOOR UNIT

 

 

U nit : mm

(ASH9USBCW / ASH12USBCW)

 

 

 

 

 

 

790

 

215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

275

OUTDOOR UNIT

(AOH9UGBC)

290

 

440

Drain pipe hold O20

54

 

 

265

500

98

695

 

535

13

250

2003.04.25

3

(AOH12UGBC)

302

272

 

540

120

 

780

55

250

535

 

 

10

 

 

2003.04.25

4

R E F R I G E R A N T S Y S T E M D I A G R A M

Models : ASH9USBCW / AOH9UGBC

ASH12USBCW / AOH12UGBC

[ INDOOR UNIT ]

Evaporator

[ Connecting pipe ]

(Flare connection)

(Flare connection)

Gas pipe (9.52 dia.)

Liquid pipe (6.35 dia.)

 

(Flare connection)

(Flare connection)

[ OUTDOOR UNIT ]

3-Way valve

 

 

2-Way valve

 

(with Charging valve)

 

Dryer

4-Way

 

valve

 

 

Check

Com- Condenser valve pressor

Capillary tube

for heating and cooling

Capillary tube for heating

Cooling

Heating

2003.04.25

5