GE GUD24ESSMWW, GUD24GSSMWW Specifications

4.6 (5)
GE GUD24ESSMWW, GUD24GSSMWW Specifications

GUD24ESSM/24GSSM

GE® Unitized Spacemaker® 2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

ELECTRICAL REQUIREMENTS:

GUD24ESSM Electric Dryer – This appliance should be connected to an individual, properly-grounded branch circuit with 120/240V single-phase 60 Hz electrical service and should be protected by 30-amp time-delay fuses or circuit breakers. This appliance is manufactured with neutral connected to the frame. Power cord should be purchased separately.

NOTE: These appliances are not approved for 120-volt operation.

GAS REQUIREMENTS:

GUD24GSSM Gas Dryer – This appliance should be connected to an individual branch circuit with a threeprong grounding-type receptacle and 120-volt singlephase 60 Hz electrical service and should be protected by 15or 20-amp time-delay fuses or circuit breakers. This appliance is equipped with a 6-foot long flexible U.L. listed 20-amp power cord to match a 15-amp receptacle.

GAS RATED input 10,500 BTU/HR. Factory equipped for natural gas. Tested for LP gas.

Dryers must be exhausted to the outside.

INSTALLATION INFORMATION: For complete information, see installation instructions packed with the product.

 

 

Installation Instructions

 

 

24" NOMINAL PRODUCT DIMENSIONS

 

 

 

*24-5/8"

 

 

 

43"

 

 

 

18"

Gas Inlet

 

 

 

 

 

Water Inlets

2-3/4"

 

 

 

74-7/8"

Vent

8-5/8"

2"

 

 

51°

 

51-3/8"

 

 

 

 

 

37-1/4"

 

 

 

33-7/8"

 

 

Drain outlet

32-3/4"

 

 

 

4-1/4"

 

21-1/8"

23-3/4"

27-3/8"

* Dimension represents door closed including handle and knobs. NOTE: With feet set at mid position, feet can be adjusted +/- 3/8".

For answers to your Monogram, GE CaféSeries, GE ProfileSeries or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 11/17

GUD24ESSM/24GSSM

GE® Unitized Spacemaker® 2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

For complete information, see installation instructions packed with your dryer.

DUCTING MATERIALS: This dryer MUST be vented with 4" diameter all rigid metal exhaust duct.

EXHAUST LENGTH CALCULATION:

1.Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.

2.The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.

For every extra 90° elbow, reduce the allowable vent system length by 10 ft. Two 45° elbows will be treated like one 90° elbow. For the side exhaust installations, add one 90° elbow to the chart. The total vent system length includes all the straight portions and elbows of the system (transition duct included).

Dryers must be exhausted to the outside.

CAUTION: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.

GUD24 DRYER EXHAUST LENGTH*

RECOMMENDED MAXIMUM LENGTH

 

Exhaust Hood Types

Recommended

Use only for short

run installations

 

 

 

 

4" DIA.

4" DIA.

4" DIA.

 

4"

 

2-1/2"

No. of 90º

Rigid

Rigid

Elbows

Metal

Metal

0

43 Feet

36 Feet

1

33 Feet

26 Feet

2

24 Feet

16 Feet