Embedded Power for Business-Critical Continuity

AIH Series

250 Watts

Total Power:

250 Watts

 

(12V @ 20.8A)

Input Voltage:

300V

# of Outputs:

Single

Special Features

250W Continuous power at 100°C baseplate temperature

High efficiency - up to 88%

Low output ripple and noise

Positive and Negative enable function

Excellent transient response

Safety isolated low voltage control and monitoring

High reliability

Wide input voltage range

Paralleable with accurate current sharing

Adjustable output voltage

Regulation to zero load

Temperature monitor output

EU Directive 2002/95/EC compliant for RoHS

Safety

UL

60950 Recognized

cUL

60950 Recognized

TUV

EN60950 Licensed

CE

CE Mark

Rev. 05.23.07

AIH Series

1 of 2

RoHS

Electrical Specifications

Input

Input range

250 - 420 VDC

Input surge

450V / 100ms

Efficiency

88% @ 5.0V (typical)

Output

 

Load Regulation

0.2% typical (5V and above); 10mV for below 5V

Line Regulation

0.2% typical (5V and above); 10mV for below 5V

Noise / ripple

100mV typical (below 5V); 2% typical (5V and above)

Output voltage adjust range

+/-20% for 5V and above; +10%/ -50% for below 5V

Transient response

5% max for 3.3V and above150mV for 1.8V, deviation with 25%

to 75% full load 250 μS (max) recovery

 

Current share accuracy

3% typical

Overvoltage protection

130% Vo (3.3 Vo and 5 Vo); 125% Vo (other Vo)

Current limit

120% Io maximum

Control

 

Voltage adjust

80 to 120% for 5V and above; +10% / -50% for below 5V

Enable

TTL compatible (positive & negative enable options)

Clock input (external sync)

3.3 to 5.5Vp-p @800 MHz ±5%

Temperature

10mV/°K (2.73 = 0°C)

monitor output

 

Current monitor output

0 to 1mA (1mA = 100% Io rated)

Notes

 

 

 

Nominal values apply with sense pins disconnected and other control pin unconnected.