Electrolux EIMED60JIW Wiring diagram

4 (1)

Dryer Tech Data Sheet

This information is intended for Qualified Technicians Only.

CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING

Please Return This Sheet to its Envelope in the Product for Future Reference

Contents

Page

Error code explanation

.............................................1

Error Code Chart....................................................

1 -2

Diagnostics .................................................................

3

Français…………………………………………......4-6

Español…………………………………………..............7-9

Wiring Diagram…………………………………….......10-11

Acronym Table

CW – Clockwise

CCW – Counter Clockwise

READING ERROR CODES

1.Wake the dryer up by pressing any button but “cancel”.

2.Press and hold the “cancel” and “start pause” buttons simultaneously for 6 seconds to show the last error code recorded. The error code will appear in the display as an E followed by two numbers. NOTE: E00 means no failure code experienced.

3.To view the last 5 error codes recorded, refer to the Diagnostic Mode listed below.

4.Troubleshoot problem by using the chart below.

 

Error

 

 

 

Possible Solutions

 

 

Code

Fault

Possible Fault Conditions

 

 

E31

Contact Sensor

Electronic Control Board defective or

Check Contact Sensor and wiring. If no problems are found with Contact

 

frequency too high

foreign object interfering with contact

 

 

 

Sensor, replace Electronic Control Board.

 

 

 

sensor

 

 

 

 

 

 

 

 

 

E32

Contact Sensor

Electronic Control Board defective or

Check Contact Sensor and wiring. If no problems are found with Contact

 

frequency too low

foreign object interfering with contact

 

 

 

Sensor, replace Electronic Control Board.

 

 

 

sensor

 

 

 

 

 

 

 

 

 

E42

Door Sensing

Electronic Control Board defective

 

Replace Electronic Control Board.

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

If motor runs continuously with power applied check for short circuit across

 

E51

Motor Relay failure

Motor Relay stuck open or closed;

motor relay (RL2), or L1 applied to motor relay output (J3-1) with cycle

 

 

 

Wiring defective

stopped. If motor does not start when “start” key is pressed, check for open

 

 

 

 

circuit between L1 and motor relay connection (J3-2). If no wiring problems

 

 

 

 

 

found, replace Electronic Control Board.

 

 

Motor Fault –

Motor overheating; Laundry load too

Remove any load from dryer and check if drum turns freely by hand. Check

 

 

E52

motor stopped or

heavy; Low power supply; Motor, or

L1 power supply voltage, motor wiring, and motor thermal protector (if motor

 

 

not starting

Wiring defective

thermal protector has tripped, it may take up to 30 minutes to reset).

 

 

 

Motor Centripetal

Motor Centripetal Switch, Electronic

Check wiring. Check if Motor Centripetal Switches are stuck in open or closed

 

E53

Control Board Defective, or wiring

 

Switch Failure

 

positions. Replace motor. Replace Electronic Control Board.

 

 

defective.

 

 

 

 

 

 

 

 

 

E54

Motor Sensing

Electronic Control Board defective

 

Replace Electronic Control Board and retest.

 

 

failure

 

 

 

 

 

 

 

Heater Relay

Heater relay stuck open or closed;

Check for short circuit across heater relay(s) (RL5, RL6, RL7) or L1 applied

 

 

E61

Wiring defective

to heater relay output(s) (J5-2, J7-1, J7-3) with cycle stopped. Check for

 

 

failure

 

open circuit between L1 and heater relay connection(s) (J5-1, J5-3, J7-2). If

 

 

 

 

no wiring problems are found, replace Electronic Control Board and retest.

 

 

E63

Heater to Earth

Heating element or wiring defective

Check heater coils and connections for short circuits to the cabinet. Replace

 

 

Ground

 

heater and/or wiring and retest.

 

E64

Heater Open

Heating element or wiring defective

Check heater coils and connections for open circuits. Replace heater and/or

 

 

 

Circuit

 

wiring and retest.

 

 

High Limit

High vent restriction, High Limit

For Electric Model, check Inlet Thermal Limiter for continuity. If Thermal Limiter

 

 

 

is open, check for evidence of high temperature event and any resulting

 

E65

Thermostat trip

Thermostat defective or Inlet Thermal

damage. If no further damage is evident, replace Thermal Limiter. If no

 

 

count too high

Limiter tripped (Electric Model only)

problems are found with the Thermal Limiter, check exhaust vent system for

 

 

 

 

air blockages. If no problems with vent restrictions, check/replace High Limit

 

 

 

 

 

Thermostat, and retest.

 

 

Thermal Limiter

Outlet Thermal Limiter tripped Inlet

Check Outlet Thermal Limiter for continuity. For Gas Model, also check Inlet

 

 

E66

Thermal Limiter for continuity. If Thermal Limiter is open, check for evidence

 

 

Open Circuit

Thermal Limiter tripped (Gas

 

of high temperature event and any resulting damage. If no further

 

 

 

Model only) or wiring defective

 

damage is evident, replace Thermal Limiter and retest.

 

 

 

 

 

 

 

E67

Heaters Sensing

Electronic Control Board defective

 

Replace Electronic Control Board and retest.

 

 

Failure

 

 

 

 

 

 

 

 

 

1

137265000B (1202)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

Fault

Possible Fault Conditions

Possible Solutions

Code

 

 

 

 

 

 

 

 

 

Outlet Control

Outlet Control Thermistor or wiring

Check resistance of Outlet Control Thermistor, and check wiring for open circuit.

 

E71

Thermistor open

 

defective

Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature

 

 

circuit

 

(68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and

 

 

 

 

retest.

 

 

E72

Outlet Control

Outlet Control Thermistor or wiring

Check resistance of Outlet Control Thermistor, and check wiring for short circuit

 

Thermistor short

across Thermistor connections. Resistance should be between 4.9K Ohm and

 

 

 

 

circuit

defective

6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control

 

 

 

 

Thermistor and/or wiring and retest.

 

 

E73

Inlet Control

Inlet Control Thermistor or wiring

Check resistance of Inlet Control Thermistor, and check wiring for open circuit.

 

 

defective

Resistance should be between 47K Ohm and 66K Ohm at room temperature

 

 

Thermistor open

 

 

 

(68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and

 

 

circuit

 

 

 

 

retest.

 

 

 

 

 

 

E74

Inlet Control

 

Check resistance of Inlet Control Thermistor, and check wiring for short circuit

 

Inlet Control Thermistor or wiring

across Thermistor connections. Resistance should be between 47K Ohm and

 

Thermistor short

 

 

circuit

defective

66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control

 

 

 

 

Thermistor and/or wiring and retest.

 

E91

Communication

Wiring, Electronic Control Board, or

Check connections between Electronic Control Board and Interface Board. If no

 

 

Error

Interface Board defective

wiring problems, replace Electronic Control Board or Interface Board.

 

 

 

E92

Incompatible

Electronic Control Board incompatible

Check if correct Interface Board console and Electronic Control Board are

 

 

protocol

with Interface Board

installed. Replace appropriate hardware.

 

 

 

 

E93

Machine

Wrong configuration data loaded,

Check if correct Interface Board and console are installed. Replace Interface

 

configuration

Interface Board or Electronic Control

 

 

Board and/or console.

 

 

checksum error

Board or wiring defective

 

 

 

 

E94

Cycle configuration

Wrong configuration data loaded or

Replace Electronic Control Board.

 

 

checksum error

Electronic Control Board defective

 

 

 

 

 

 

 

 

 

 

 

E97

Program mismatch

Wrong configuration data loaded,

Replace Electronic Control Board.

 

 

 

Electronic Control Board defective

 

 

 

 

EA1

Main Supply

Line frequency out of limits or

Check frequency of line voltage.

 

Frequency out of

Electronic Control Board faulty

 

 

 

 

 

 

Range

 

 

 

 

 

EA2

Voltage too high

Line voltage too high or Electronic

Check amplitude of line voltage.

 

 

 

Control Board faulty

 

 

 

 

 

 

 

 

 

 

EA3

Voltage too low

Line voltage too low or Electronic

Check amplitude of line voltage.

 

 

Control Board faulty

 

 

 

 

 

 

 

 

 

 

 

 

 

EA4

Improper home

Line connections in home faulty,

 

 

 

 

wiring or Electronic Control Board

Check wiring at terminal block for L1-N-L2 wired incorrectly.

 

wiring

 

 

defective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EA5

Main V Sensing

Electronic Control Board defective

Replace Electronic Control Board.

 

 

failure

 

 

 

 

 

EF1

Vent Blocked

High vent restriction, Exhaust Control

Check vent restrictions and resistance values of Exhaust Control Thermistor

 

Thermistor, Inlet Control Thermistor, or

and Inlet Control Thermistor.

 

 

 

Electronic Control Board defective

 

 

 

 

EF3

Max Timeout Timer

Exhaust blocked; Exhaust Control

Check vent restriction, Contact Sensor, and resistance values of Exhaust

 

Thermistor, Inlet Control

Control Thermistor and Inlet Control Thermistor

 

 

 

Thermistor, Contact Sensor or

 

 

 

 

 

 

Electronic Control Board defective

 

 

 

 

EF8

Key Stuck

Console button or Interface Board

Check buttons for activation when pressed. Replace console or Interface Board

 

 

defective

as appropriate

 

 

 

 

 

 

 

 

 

FACTORY RESET

1. Press and hold the “Temperature” and “Dryness” buttons simultaneously for 6 seconds.

INSTALLATION CYCLE

1.Use the selector knob to select the “touch up” cycle

2.Press and hold the “my favorite” and “sanitize” buttons simultaneously for 6 seconds.

3.Remove any load from the dryer and press “start pause” to start installation cycle.

DIAGNOSTIC MODE

1.Press the “cancel” button to enter standby mode and enable diagnostic entry.

2.Within 10 seconds after pressing “cancel”, press any button (but “cancel”) to wake up the control.

3.Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the “cancel” and the far left button under the display simultaneously for 3 seconds to enter the Diagnostic Mode. (note: to save time at wake up, the welcome screen can be bypassed by turning the selector knob).

4.Upon entering Diagnostic Mode, all lights should flash on and off.

5.The following steps can be cycled through by turning the selector knob clockwise:

2

Electrolux EIMED60JIW Wiring diagram

Diagnostic Mode

Selector

Test/Activated Component

Operator Check

LCD row

LCD digits

Position

Electric

Gas

 

 

 

0

Lights / Buttons test

 

 

 

1

Motor Clockwise (CW)

Check Motor function. Look for Drum

“MOTOR CW”

 

rotation in clockwise direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check moisture reading. Place fingers

 

“1111” if Contact Sensor

2

Contact Sensor

across Contact Sensor and look for digit

“MOIST. BARS”

open circuit;”8888" if

display to change from “1111” to “8888”

Contact Sensor short

 

 

 

 

 

 

 

 

 

circuited

 

 

 

 

 

 

3

Motor Clockwise (CW)

Check Motor function. Look for Drum

“MOTOR CW”

 

rotation in clockwise direction

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights / Buttons

Lights / Buttons

Check all buttons and lights. Press all

 

button id number

4

buttons and check for beep and button

 

test + Motor CW +

 

test + Motor CW

ID number in digit display. Check to see

 

 

 

igniter

 

 

 

 

that all Lights function

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Motor CW + Heater

Motor CW +

Check Motor and Heater function. Check

 

Outlet Control Thermistor

Outlet Control Thermistor value in digit

 

Heater

“HEAT1 - NTC1”

 

1

display.

value (degrees F)

 

 

 

 

 

 

 

 

 

6

Motor CW + Heater

Motor CW +

Check Motor and Heater function. Check

 

Inlet Control Thermistor

Inlet Control Thermistor value in digit

 

Heater

“HEAT2 - NTC2”

 

1 + Heater 2

display.

value (degrees F)

 

 

 

 

 

 

 

 

 

7

Motor CW + Heater

Motor CW +

Check Motor and Heater function. Check

“HEAT3 - NTC1”

Outlet Control Thermistor

1 + Heater 2 +

Outlet Control Thermistor value in digit

Heater

 

 

Heater 3

display.

 

value (degrees F)

 

 

 

 

 

 

 

 

 

8

Motor CW

Check for Mist

“MIST VALVE”

 

 

 

 

 

 

 

9

Error code history display

Check last 5 error codes displayed (See

 

error code

 

 

 

Table above for error code definitions)

 

 

 

 

 

 

 

10

Software version

Software version

Software

Software version

version

NOTE : To clear the error code (s): Press and hold the far left key under the display and “cancel” buttons simultaneously for 3 seconds.

6.To exit Diagnostic Mode:

a)Unplug the power cord, wait 5-8 seconds, then reconnect the power cord OR

b)Turn the program knob to the Start Position (lights/Buttons Test). Press the “cancel” and far left button under the display simultaneously for 6 seconds.

3

Fiche de données techniques de sécheuse

Informations réservées aux techniciens qualifiés.

ATTENTION : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT D’EFFECTUER TOUT ENTRETIEN

Replacez cette fiche dans son enveloppe dans l’appareil pour référence ultérieure

Tableau des acronymes

SH - Sens horaire

SAH - Sens antihoraire

LECTURE DES CODES D’ERREUR

1.Réveillez la laveuse en appuyant sur une touche quelconque, sauf “cancel (annuler)”.

2.Appuyez et maintenez simultanément appuyées les touches “cancel (annuler)” et “start (départ)/ pause” pendant 6 secondes pour afficher le dernier code d’erreur enregistré.

Le code d’erreur s’affiche à l’écran sous la forme d’un E suivi de deux chiffres. REMARQUE : E00 signifie qu’il n’existe aucun code d’erreur.

3.Pour afficher les 5 derniers codes d’erreur enregistrés, référez-vous au mode Diagnostic listé ci-dessous.

4.Vérifiez la source du problème en utilisant le tableau ci-dessous.

Code

 

 

 

 

d’erreur

Anomalie

États d’anomalie

Solutions

E31

Fréquence du

Carte de contrôle électronique

Vérifiez le capteur à contact et le câblage. Si le capteur à contact ne

 

capteur à contact

défectueuse ou corps étranger

présente aucun problème, remplacez la carte de contrôle électronique et

 

trop élevée

interférant avec le capteur à

faites un nouveau test.

 

 

contact

 

 

E32

Fréquence du

Carte de contrôle électronique

Vérifiez le capteur à contact et le câblage. Si le capteur à contact ne

 

capteur à contact

défectueuse ou corps étranger

présente aucun problème, remplacez la carte de contrôle électronique et

 

trop basse

interférant avec le capteur à

faites un nouveau test.

 

 

contact

 

 

E42

Défaillance du

Carte de contrôle électronique

Remplacez la carte de contrôle électronique et faites un nouveau test.

 

capteur de la porte

défectueuse

 

 

E51

Défaillance du

Relais du moteur bloqué en

Si le moteur fonctionne continuellement sous tension, vérifiez la présence

 

relais du moteur

position ouverte ou fermée ;

d’un court-circuit au niveau du relais du moteur (RL2), ou L1 à la sortie du

 

 

Câblage défectueux

 

relais du moteur (J3-1) lorsque le cycle est arrêté. Si le moteur ne démarre

 

 

 

 

pas lorsque vous appuyez sur la touche “start (départ)”, vérifiez si le

 

 

 

 

circuit est ouvert entre L1 et la connexion du relais du moteur (J3-2). Si le

 

 

 

 

câblage ne présente aucun problème, remplacez la carte de contrôle

 

 

 

 

électronique et faites un nouveau test.

E52

Anomalie moteur -

Surchauffe du moteur ; Le linge

Retirez le linge de la sécheuse et vérifiez si le tambour tourne librement

 

le moteur est

est trop lourd ; Tension

avec la main. Vérifiez la tension de l’alimentation L1, le câblage et le

 

arrêté ou ne

d’alimentation basse ; Moteur ou

protecteur thermique du moteur (si le protecteur thermique s’est déclenché,

 

démarre pas

câblage défectueux

 

la réinitialisation peut prendre jusqu’à 30 minutes).

E53

Défaillance de

Interrupteur du moteur de type

Vérifiez le câblage. Vérifiez si les interrupteurs du moteur de type

 

l’interrupteur du

centripète, carte de

contrôle

centripète sont bloqués en position ouverte ou fermée. Remplacez le

 

moteur de type

électronique ou

câblage

moteur. Remplacez la carte de contrôle électronique.

 

centripète

défectueux.

 

 

E54

Défaillance du

Carte de contrôle électronique

Remplacez la carte de contrôle électronique et faites un nouveau test.

 

capteur du moteur

défectueuse

 

 

E61

Défaillance du

Relais de l’élément chauffant

Vérifiez la présence d’un court-circuit entre les relais de l’élément

 

relais de l’élément

bloqué en position ouverte ou

chauffant (RL5, RL6, RL7) ou L1 appliqué aux sorties du relais de l’élément

 

chauffant

fermée ; Câblage défectueux

chauffant (J5-2, J7-1, J7-3) lorsque le cycle est arrêté. Vérifiez si le

 

 

 

 

circuit est ouvert entre L1 et les connexions du relais de l’élément chauffant

 

 

 

 

(J5-1, J5-3, J7-2). Si le câblage ne présente aucun problème, remplacez

 

 

 

 

la carte de contrôle électronique et faites un nouveau test.

E63

Élément chauffant

Élement chauffant ou câblage

Vérifiez les bobines de l’élément chauffant et les connexions à la recherche

 

à la terre

défectueux

 

de courts-circuits dans la carrosserie. Remplacez l’élément chauffant et/

 

 

 

 

ou le câblage et faites un nouveau test.

E64

Élément chauffant

Élement chauffant ou câblage

Vérifiez les bobines de l’élément chauffant et les connexions à la recherche

 

avec indication de

défectueux

 

de circuits ouverts. Remplacez l’élément chauffant et/ou le câblage et

 

court-circuit

 

 

faites un nouveau test.

E65

Nombre de

Évent haut obstrué, thermostat

Pour le modèle électrique, vérifiez la continuité du limiteur thermique

déclenchements

de limite-haute défectueux ou

d’entrée. Si le limiteur thermique est ouvert, vérifiez s’il existe des indices

 

 

du thermostat de

déclenchement

limiteur

de dommages résultant de températures élevées. S’il n’existe aucune

 

limite-haute trop

thermique d’entrée

(modèle

évidence de dommage, remplacez le limiteur thermique. Si le limiteur

 

élevé

électrique uniquement)

thermique ne présente aucun problème, vérifiez si le système d’évacuation

 

 

 

 

est obstrué. Si ce système n’est pas obstrué, vérifiez/remplacez le

 

 

 

 

thermostat de limite-haute, et faites un nouveau test.

 

 

 

 

 

4