Page 1/4 |
Identification: |
A14 - N900 |
Tech. Bulletin n°: |
PDX2005-02 |
Date: |
26-05-2005 |
Issuer: |
M. Scalon (TT&S) |
Factory: |
PD-Vallenoncello Modular Cooking |
|
|
Subject |
N900 |
PASTA |
COOKERS: |
NEW |
WATER |
|
|
SOLENOID VALVE |
|
|
|
||
Model |
200372, |
200373, |
200374, |
200375, |
200376, |
200377, |
|
200378, |
200379, |
200380, |
200381, |
200382, |
200383, |
|
200396, |
200397, |
200398, |
200399, |
200400, |
210376, |
|
210377, |
210378, |
210379, |
210380, |
210381, |
210382, |
|
210383, |
220376, |
220377, |
220378, |
220379, |
220380, |
|
220381, 220382, 220383, 224009 |
Problem |
The solenoid breaks in case of: |
|
- lack of water in the main water supply net; |
|
- hot water supplied to the pasta cooker. |
Reason |
- The solenoid is designed for intermittent duty. |
Actions in |
- New components from s/n 521… |
factory |
- Updated the spare part lists. |
|
- New components to install: |
|
1. Water solenoid valve (new code: 0C2390); |
|
2. n°2 hose carriers (code: 0C1626) for inner |
|
water connections; |
Actions in |
The new components are available as spare part. |
field |
|
The present modification can be retrofitted but it is not mandatory
For the spare part code of each component see also the Spare Parts Catalogue.
ELECTROLUX PROFESSIONAL SPA |
TELEPHONE |
TELEFAX |
E-MAIL ADDRESS |
POSTAL ADDRESS |
+39 0434 380582 |
+39 0434 380577 |
claudio.marziani@electrolux.it |
V.le Treviso 15 |
+39 0434 380583 |
|
mara.scalon@electolux.it |
33170 PORDENONE – ITALIA |
|
|
|
Page 2/4
Tech. Bulletin PDX2005-02
OLD WATER SOLENOID VALVE |
|
NEW WATER SOLENOID VALVE |
|
|
|
Solenoid ‘class F’ |
Body in brass |
Room temperature 80 °C |
|
To replace the new water solenoid valve on equipments older than s/n 521… it is needed to run also the following modifications:
9Bottom: it is needed to drill 2 holes (diam. 6 mm) for fitting the valve round the main water inlet hole (see picture below);
16.5
Φ 5
31°
10
26
16
Φ 30
water inlet hole
17°