Page 1/2 |
Identification: |
A16 – N700, A14-N900 |
Tech. Bulletin n°: |
PDX2007-02 |
Date: |
15-01-2007 |
Issuer: |
M. Scalon (TT&S) |
Factory: |
PD-Vallenoncello Modular Cooking |
|
|
Subject |
QUALITY IMPROVEMENT: WATER FILTER ON |
|||||
|
PASTA COOKER N700, N900. |
|
|
|||
Model |
178147, |
178148, |
178149, |
178448, |
200372, |
200373, |
|
200374, |
200375, |
200376, |
200377, |
200378, |
200379, |
|
200380, |
200381, |
200382, |
200383, |
200396, |
200397, |
|
200398, |
200399, |
200400, |
210376, |
210377, |
210378, |
|
210379, |
210380, |
210381, |
210382, |
210383, |
220376, |
|
220377, |
220378, |
220379, |
220380, |
220381, |
220382, |
|
220383, 224009. |
|
|
|
|
|
Problem |
Water valves are blocked. |
|
|
|
||
Reason |
Particles with grains less than 0.1mm go inside the |
|||||
|
water valve through the filter. |
|
|
|||
Actions in |
Introduced new filter with mesh 0.05mm. |
|
||||
factory |
Spare part code 0C4113 (factory code 806862800). |
|||||
|
New filter from s/n 650… |
|
|
|
||
Actions in |
If needed replace the old filter with the new one or put a |
|||||
field |
thicker mesh inside it. |
|
|
|
The present modification can be retrofitted but it is not mandatory
ELECTROLUX PROFESSIONAL SPA |
TELEPHONE |
TELEFAX |
E-MAIL ADDRESS |
POSTAL ADDRESS |
+39 0434 380582 |
+39 0434 380577 |
claudio.marziani@electrolux.it |
V.le Treviso 15 |
+39 0434 380583 |
|
mara.scalon@electolux.it |
33170 PORDENONE – ITALIA |
|
|
|