Danby DPAC10010, DPAC9010 User Manual

0 (0)

Owner’s Use and Care Guide

Guide d’utilisation et soins de Propriètaire

Model • Modèle

DPAC9010, DPAC10010

CAUTION:

MISE EN GARDE :

Read and follow all

Veuillez lire

safety rules and

attentivement les

operating instructions

consignes de sécurité et

before first use

les directives

of this product.

d'utilisation avant

 

l'utilisation initiale de

 

ce produit.

PORTABLE AIR CONDITIONER

Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 - 10

Welcome

Important Safety Information

Features

Installation

Operation

Care and Maintenance

Troubleshooting

CLIMATISEUR PORTATIF

Guide d’utilisation et soins de Propriètaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11 - 20

Bienvenue

Consignes de Sécurité Importante

Caractéristiques

Installation

Fonctionnement

Soins et Entretien

Dépannage

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE:

If the unit changes ownership, be sure the manual accompanies this unit. CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEUR: En cas de revente l’appareil, ce manuel doit être inclus avec l’appareil.

Danby Products Ltd, Guelph, Ontario Canada N1H 6Z9

Danby Products Inc, Findlay, Ohio USA 45840

V1.12.09 JF

WELCOME

Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.

Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed to offer you the functions of; Air Conditioning, Dehumidifying, and Independent Fan. Each individual mode is featured with “oscillating” air swing capabilities. This unit can be conveniently moved from room to room within your home and set up in just minutes. Imagine the convenience of 4 Season Home Comfort at your fingertips, anywhere, anytime.

For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.

Model Number:

Serial Number:

Date of Purchase:

This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer Service Representative, call Danby TOLL FREE: 1-800-26- (1-800-263-2629)

1

IMPORTANT SAFETY INFORMATION

READ ALL SAFETY INFORMATION BEFORE USING

ELECTRICAL

SPECIFICATIONS

1)Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2)This appliance draws 7.8 nameplate amps under Cooling Mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.

3)For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician.

WARNING: Improper connection of the grounding plug can result in risk of Fire, Electric Shock, and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.

4)DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only (available at most local hardware stores).

5)To avoid the possibility of personal injury, always disconnect the power supply to the unit before installing and/or servicing.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

9.5

16

 

AWGAmerican Wire Gauge

*Based on copper wire at 60°C temperature rating.

 

TABLE 2

 

 

 

Receptacle and Fuse Types

 

 

Rated Volts

125

 

 

Amps

13

 

 

Wall Outlet

 

 

 

 

 

 

 

Fuse Size

15

 

 

 

 

 

 

 

 

Time Delay Fuse

Plug Type

(or Circuit Breaker)

 

 

 

 

 

CAUTION: Do not leave this unit unattended in a space where people or animals cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.

POWER

The power cord supplied with this air conditioner contains a device that senses damage to

SUPPLY CORD the power cord. To test if your power cord is working properly, you must do the following:

1)Connect the power supply cord to an electrical outlet.

2)The power supply cord has two buttons located on the head of the plug. One button is marked “TEST”, and the other is marked “RESET”. Press the “TEST” button; you will hear a click as the “RESET” button pops out.

3)Press the “RESET” button; you will hear a click as the button engages.

4)The power supply cord is now energized and supplying electricity to the air conditioner (on some products this is also indicated by a light on the plug head).

NOTE: The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. In the event the power supply cord is damaged, it cannot be repaired and must be replaced with a new cord from the product manufacturer.

Under no circumstances should this device be used to turn the unit on or off.

The “RESET” button must always be pushed in (engaged) for correct operation.

The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in.

2

IMPORTANT SAFETY INFORMATION (cont’d)

 

 

 

 

ENERGY-SAVING

Your Danby appliance is designed to be highly efficient in energy savings. Follow these

TIPS

recommendations for greater efficiency.

 

 

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times.

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.

4)Start your air conditioner before the outdoor air becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.

5)When outdoor temperatures are cool enough, turn the air conditioner off and use the FAN MODE. This circulates indoor air, providing some cooling comfort while utilizing less electricity.

FEATURES

Air Exhaust

 

 

 

 

 

 

Air Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCD

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

Air inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air inlet

 

 

 

 

 

 

 

 

 

 

 

Front

 

Cover

 

 

 

 

 

 

 

 

 

 

 

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electricity cable

 

 

 

 

 

 

 

 

Water drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wheels

 

 

 

 

 

 

 

 

3

Danby DPAC10010, DPAC9010 User Manual

INSTALLATION

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

Caution: To avoid installation/operation difficulties, read these instructions thoroughly.

Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2 pcs)... from 17 7/10 (45cm) to 53 1/6” (135cm)

Flexible Exhaust Hose (11cm) & Exhaust nozzle connector (2pcs)...from 15 3/4” (40cm) to 51 1/5” (130cm)

Adjustable sliding window/door kit (3 pcs)... from 28 1/3”(72cm) to 80” (203cm)

Fixture..... (2 pcs) & Screws..... (8 pcs)

NOTE: The exhaust/window kit must be installed at all times when the unit is operating under AIR CONDITIONING mode. There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface.

Fig. 1 INSTALLATION ACCESSORIES

 

 

Flexible Exhaust Hose

 

 

 

 

 

Fixture

Exhaust Nozzle

 

 

 

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

Screws

Sliding Window Kit:

28 1/3” (72cm)- 80” (203cm)

Water hose (79”/ 200cm)

Instructions for Assembling the Sliding Window KitFig. 2

1)Insert tube adapters through the back of the window panel.

2)Secure each tube adapter with four screws through the front of the window panel.

3)Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place.

Fig. 2

 

 

Back of window panel

Tube Adapters

WINDOW KIT INSTALLATION

Air Conditioning Mode ONLY: Your window kit has been designed to fit most standard “vertical”/ ”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.

1)Select a suitable location, making sure you have access to an electrical outlet.

2)Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the exhaust opening and twist to lock into position.

3)Install the adjustable Sliding Window Kit as required (see Fig. 4a & 4b).

4)Install the opposite end of the flexible exhaust hose into the window exhaust adapter.

5)Install the window exhaust adapter into the opening in the slider section, making sure the window slider sections are secure.

6)Plug the unit into a 115V/60Hz grounded electrical outlet.

 

 

 

 

 

 

 

 

 

 

 

 

Fig 3a

 

 

Fig 3b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Window

 

 

 

Sliding Window

 

 

 

 

 

 

 

 

 

Kit:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.: 28 1/3

 

 

 

 

 

 

 

Vertical

 

(72cm)

 

 

 

 

 

 

 

Window

 

Max.: 80”

 

 

 

 

 

 

 

 

 

(203cm)

 

 

 

Sliding Window Kit:

 

 

 

 

 

 

 

 

Min.: 28 1/3” (67.5cm)

 

 

 

 

 

Max.: 80” (203cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

OPERATION

 

 

 

 

 

Warning Light

 

 

 

Receiving Sensor

 

 

 

 

 

 

 

 

 

KEY PAD FUNCTIONS

POWER SWITCH: Turns unit ON/OFF

MODE: Allows you to scroll through and select desired operating mode.

FAN: Select from three different fan settings;

High, Medium, and Low.

AUTO-TIMER

AUTO-TIMER Adjust:

AUTO TURN OFF- With machine in running mode, press timer button to set timer control. Press

buttons to select number of hours you would like the unit to run before it automatically shuts off.

AUTO TURN ON- With machine in stand by mode, press timer button to set timer control. Press

buttons to select number of hours before the unit automatically starts running in air conditioning mode.

NOTE: The time is adjustable between 1-24 hours.

TEMPERATURE Adjust:

Used for adjusting the thermostat.

The default display is room temperature.

In cooling mode, when button is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode.

NOTE: By pressing both buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit.

Warning Light

Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning signal in the LCD Display will light up and the unit will not operate until it has been drained.

LCD Display

Cooling Mode

Dehumidify Mode

Fan Only Mode

High Fan Speed

Medium Fan Speed

Low Fan Speed

Display Set Temperature

Display Timer Setting of Auto Switch ON /

OFF

Warning Light (the machine will stop

running)

5