DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 1

SAFETY INSTRUCTIONS

PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE INSTALLING AND OPERATING THE UNIT:

This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently.

IMPORTANT NOTES

Adhere to all safety instructions and warnings throughout this manual.

Read this manual carefully before installing or operating this unit to become familiar with its features and obtain the performance that will bring you continued enjoyment for many years.

Follow each installation or repair step exactly as shown in the manual.

Observe all local, state and national electric codes. Contact your local government for more information on electrical codes.

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

Contact Installer if Necessary:

The installation instructions are for a experienced installer. If you are not an experienced installer, contact a local installer for help. If you require help with service, contact your certified dealer or Daewoo Electronics for additional instructions.

If Unit is Installed Improperly:

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this manual.

WARNING:

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT TO WIRE THIS SYSTEM.

THE APPLIANCE IS NOT INTENDED FOR USE BY CHILDRENOR INFIRM PERSONS WITHOUT SUPERVISION.

YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT DO NOT PLAY WITH THE APPLIANCE

Precautions When Wiring:

Do not plug in the unit until all connections (tubing, drain hose, mounting, etc.) have been made and double-checked.

High voltages are present in this unit and are very dangerous. Please refer to these instructions and diagrams when wiring. Improper connections or inadequate grounding can cause accidental injury.

This unit must be grounded in accordance with local electrical codes.

Connect wires and pipes securely and tightly as loose connections/wiring may cause overheating at connections and a possible fire hazard.

Precautions When Transporting:

When transporting the unit, be very careful and get help as the units are very heavy. Be careful of sharp edges on the units also.

Precautions When Installing:

When installing in a ceiling or wall, make sure the ceiling/wall is strong enough to hold the unit’s weight. A frame may be necessary for added support.

When installing in a room, make sure the tubes are well insulated to protect the walls and furniture from sweating of the tubes.

When installing in moist or uneven locations, make sure to use a raised level concrete pad or concrete blocks to provide a level, solid foundation for the outdoor unit; this prevents water damage and vibration.

When installing in an area of high winds, make sure to securely anchor the outdoor unit down with bolts and a metal frame.

When Connecting Refrigerant Tubing:

Keep all tubing as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten , making sure not to overtighten.

Check the tubes carefully for leaks before starting the test run.

When Servicing:

Make sure the power is off and the unit is unplugged before opening the unit to troubleshoot or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the sight after you finish, making sure no metal scraps and wiring are left in the unit.

The Air conditioner shall be installed in accordance with the nationed wiring regulation.

The equipment fulfills the requirements in EN 61 000-3-11 and is subject to conditional connection to the mains.

It may be connected in consultation with the supply authority.

The equipment may only be connected to a mains supply with a system impedance of less than 0.3 ohm.

The system impedance in the interface point may be obtained from the supply authority.

If the mains supply has a higher system impedance, short voltage dips may appear when the equipment is started or during operation.

This may influence or disturb the operation of other apparatuses, e. g. flickering lamps, especially those connected to the same supply mains.

1

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 2

ROOM AIR CONDITIONER INSTRUCTION

Remark per EMC Directive 89/336/EEC

To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply.

1.The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an low impedance. Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max!

2.No other equipment has to be connected to this power line.

3.For detailed installation acceptance please refer to your contract with the power supplier.

If restrictions do apply for products like washing machines, air conditioners or electrical ovens.

4.For power details of the air conditioner refer to the rating plate of the product.

CONSIGINES D’INSTALLATION RACCORDEMENT ELECTRIQUE

Remarques relatives à la Directive EMC 89/336/CEE

Pour eviter les phénormènes de scintillements(variation de lumière) et les parasites lors du démmarrage du compresseur, respect er les consignes d’installation décrites dans le mode d’emploi.

1.Le raccordement au secteur doit être-fait à l’aide d’un cable de section suffisante pour eviter tout échauffement de celui-c i et les chutes de tension (section recommandée 3x4mm2)

Cette ligne doit être protégée par un fusible ou disjoncteur de 16A

2.Aucun autre appareil ne doit être connecté sur cette ligne.

3.En cas de doute ou de difficulté contactez votre agence EDF. Vériflez qu’il nexiste pas de contraintes particulères pour l’i nstalation et l’utilisation de ce climatiseur.

4.Pour les caractéristiques de l’appareil référez vous à sa plaque signalétique.

INSTRUCCIONES DE INSTALACION DEL AIRE ACONDICIONADO

Comentario de la Directiva 89/336 EEC de la EMC.

ára prevenir la sensación de golpeteo al arrancar el compresor(procesotécnico) debe aplicar las siguientes instrucciones de ins talación

1.La conexión del aire acondicionado a la corriente eléctrica tiene que ser hecha a la distribución principal de energía. Esta distribución tiene que ser de baja impedancia. Normalmente, la impedancia requerida se alcanza en el punto de fusión de 32A. El fusible del aire acondicionado tiene que ser de 16A máximol.

2.Ningún otro equipo debe ser conectado a esta línea eléctrica.

3.Para normas detalladas de instalación por favor consulte el contrato con su suministador eléctrico, si tiene que aplicar restricciones para productos como lavadoras, aire acondicionado u homos eléctricos.

4.Para detalles sobre las alimentación eléctrica del aire acondicionado consulte la placa de datos del aparato.

ANWEISUNGEN ZUR INSTALLATION DER RAUM-KLIMAANLAGE

Hinweis entsprechend EMV-Direktive 89/336/EEC

Um einen “Flicker-Effekt” beim Anlauf des Kompressors (kurzzeitiger Spannungseinbruch, technischer Vorgang) zu vermeiden, muß ürf folgende installationsbedingungen gesorgt sein. (siche auch “Anweistingen zur installation.”)

1. Der Stromanschluß für die Klimpaanlage muß am Hauptverteller vorgenommen werden. Die Abzweigung muß mit niedriger Impedanz a usgeführt werden. Normalerweise ist die erforderliche niedrlge impedanz bei einem Sicherungsanschlußpunkt von 32A erreicht.

2.An die gleíche Netzleitung dürfen keine anderen Geráte angeschlossen sein.

3.Seitens der lokaten Energieversorgungsuntemehmen bestehen möglicherweise Einschránkungen für Produkte wie Waschmaschinen, Klimaanlagen, elektrische Öfen, etc. Für Einzelheiten zur Installation sehen Sie in Ihren Vertrag mit dem Energieversorgungsunt ernehmen.

4.Einzelheiten über die elektrischen Daten der Kimaanlage ersehen Sie auf dem Typenschild des Gerates.

INSTRUZIONI PER L’INSTALLAZIONE DEL CONDIZIONATORE

D’ARIA PER STANZE

NOTA DELLA DIRETTIVA EMC 89/336 EEC

Allo scopo di prevenire l’ effetto di FLICKER (variazione della luce) alla partenza del compressore, durante l’installazione seguire l punti sottoelencatl.

1.Il collegamento dell’ alimentazione, del condizionatore, deve essere fatto con una linea preferenziale dlrettamente al quadro principale o contatore, e deve essere a bassa impedenza.

Normalmente questa lmpedenza la si ottiene al punto di fusione di 32 A ; perll condizionatore usare un fusibile da 16 A max.

2.Nessun altro apparecchio elettrico dovra essere collegato alla stessa linea di alimentazione.

3.Per maggiori dettagll circa l’ accettazione dell’ installazione del condizionatore, fare riferimento al contratto con l’ Ente erogatore dell’ Energla Elettrica e verificare che non ci siano restrizioni in atto all’ Installazione di prodottl elettrici ad alto consumo.

4.Per le informazioni relative ai dati di allmentazlone del condizionatore, fare riferimento all’ etichetta posta sul prodotto.

2

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 3

CONTENTS

It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit.

Safety Instructions ...........................................................................................................................................................

1

Contents...........................................................................................................................................................................

3

Location of Controls.........................................................................................................................................................

4

Indoor Unit........................................................................................................................................................

4

Outdoor Unit .....................................................................................................................................................

4

Remote Controller ............................................................................................................................................

6

Remote Display ................................................................................................................................................

6

Operation .......................................................................................................................................................................

10

Connecting the AC Cord ................................................................................................................................

10

Setting the Unit for Remote Operation...........................................................................................................

10

How to Install Batteries ..................................................................................................................................

11

Celsius to Fahrenheit Conversion Chart........................................................................................................

11

To Set Auto Mode ..........................................................................................................................................

12

To Set Quick Mode ........................................................................................................................................

12

To Set Cool Mode ..........................................................................................................................................

12

To Set Fan Only Mode...................................................................................................................................

13

To Set Dehumidifier Mode .............................................................................................................................

13

To Set Heat Mode (DSB-123LH/123PH Only) ..............................................................................................

14

To Select The Fan Direction ..........................................................................................................................

14

To Set Air-Cleaning (PLASMA) Mode (DSB-123PH)....................................................................................

15

To Set Air-Cleaning (OXYGEN) Mode (DSB-123AH) ...................................................................................

16

To Set On Timer Mode ..................................................................................................................................

17

To Set Off Timer Mode...................................................................................................................................

17

To Set Unit to Sleep Mode.............................................................................................................................

18

To Set Turbo/Mild Mode ................................................................................................................................

18

Emergency Operation ....................................................................................................................................

18

Changing/Cleaning the Air Filters..................................................................................................................................

19

Cleaning the Indoor Cover ............................................................................................................................................

19

Care and Maintenanc ....................................................................................................................................................

20

Troubleshooting Guide ..................................................................................................................................................

21

3

Daewoo DSB-123L Manual

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 4

LOCATION OF CONTROLS

INDOOR UNIT

 

 

 

 

Deodorizing Filter

 

 

Electrostatic Filter

 

 

 

 

Removes bad smells

 

 

 

 

 

 

Air In

 

Electric Dust Collector (DSB-123PH Only)

Indoor Cover

 

 

 

from the air.

 

 

Removes dust

 

 

 

 

 

 

 

 

 

 

 

 

particles from the air.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Cleaning Filters

 

COVER 02 HOSE

 

 

 

Removes dust and

 

 

 

prohibits germs.

 

Connection Cover

Sensor Wire

 

 

(Heat Pump Model Only)

Fan Direction

 

Remove cover to access

 

(Up/Down)

Cold Air the AC connection from

 

 

Remote

this unit to the outdoor unit.

 

 

Sensor

 

 

 

 

 

 

Emergency/Remote

 

 

Indicators

Switch

 

 

Indicate the setting

Slide to select the

 

 

 

desired position.

 

 

 

 

Power Plug

 

Remote Controller

 

 

OUTDOOR

AIR IN

AIR OUT

Connection Cover

Remove cover to access the AC connection to the indoor unit.

Service Valves

The indoor and outdoor units are connected by copper tubes which are connected here.

4

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 5

INDOOR UNIT

Indoor Unit Display

Remote Control Signal Receiver

This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. beep”.

 

 

 

 

 

 

 

 

 

 

 

 

 

Air clean

 

Timer (Yellow)

 

(Green)

 

Lights during the time

 

 

 

 

reservation mode.

 

 

 

 

 

 

ON (Red)

Quick (Red)

Lights when the

Lights during the

operation is going on.

time Quick

 

 

 

Mode.

 

 

 

 

 

 

Switch Panel

EMERGENCYREMOCON

EMERGENCYMOCON

There is a switch panel at inside of Front Panel.

At the time of operating, open the Front Panel.

Emergency switch can be used when the remote controller is lost or Testing.

Remote switch is usually used by remote controller.

5

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 6

DSB-123L/DSB-F123L

REMOTE CONTROLLER

AUTO

FAN SPEED Button

Press to select the fan speed (High " ", Middle " ", Low " ", Natural).

MODE Button

Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier)

SLEEP Button

Press to set the unit for the sleep mode.

TIMER ON/OFF Button

Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)

TIMER ENTER/CANCEL Button

Press to enter a timer setting or to cancel timer setting

MODE

FAN SPEED

FAN DIR.

SLEEP

 

 

TIMER

 

ON/OFF

ENTER/

TURBO/MILD

 

CANCEL

 

Display

Display information

ON/OFF Button

Press to turn the unit on or off.

TEMPERATURE Buttons

Press to raise or lower the desired temperature.

FAN DIR. Button

Press to select up/down direction for fan.

TURBO/MILD

Press to select super power operation (Turbo) mode.

COVER

Slide down to access most of the remote buttons. Slide down further to access the battery compartment.

REMOTE DISPLAY

MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier)

Light to indicate the mode selected.

AUTO

FAN Indicators

Light to indicate the fan speed.

NATURAL Indicator

Light to indicate the speeds simulating a breeze.

FAN DIRECTION Indicators

Light to indicate the fan direction.

TIMER Indicators (Include sleep)

Light to indicate the timer function mode.

TEMPERATURE & RESERVATION TIME lndicators

Light to indicate the temperature or time.

6

DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 7

DSB-123LH

REMOTE CONTROLLER

AUTO

FAN SPEED Button

 

 

 

Press to select the fan speed

 

 

 

(High " ", Middle " ", Low " ",

MODE

FAN SPEED

FAN DIR.

Natural).

 

 

 

MODE Button

SLEEP

 

 

Press to cycle through the modes

 

 

TIMER

 

(Auto/Quick/Cool/Fan/Dehumidifier/

 

 

 

Heat)

ON/OFF

ENTER/

TURBO/MILD

SLEEP Button

 

CANCEL

 

 

 

 

Press to set the unit for the sleep

 

 

 

mode.

 

 

 

TIMER ON/OFF Button

Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)

TIMER ENTER/CANCEL Button

Press to enter a timer setting or to cancel timer setting

Display

Display information

ON/OFF Button

Press to turn the unit on or off.

TEMPERATURE Buttons

Press to raise or lower the desired temperature.

FAN DIR. Button

Press to select up/down direction for fan.

TURBO/MILD

Press to select super power operation (Turbo) mode.

COVER

Slide down to access most of the remote buttons. Slide down further to access the battery compartment.

REMOTE DISPLAY

MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)

Light to indicate the mode selected.

AUTO

FAN Indicators

Light to indicate the fan speed.

NATURAL Indicator

Light to indicate the speeds simulating a breeze.

FAN DIRECTION Indicators

Light to indicate the fan direction.

TIMER Indicators (Include sleep)

Light to indicate the timer function mode.

TEMPERATURE & RESERVATION TIME lndicators

Light to indicate the temperature or time.

7

Loading...
+ 16 hidden pages