Broan EW4824SS, EW4830SS, EW4830BLS, EW4830WH, EW4836SS INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

...
0 (0)

WWW.BROAN.COM WWW.BROAN.CA

CHIMNEY

RANGE HOOD

EW48 Series

INSTALLATION, USE

AND CARE MANUAL

Serial number:

99046144C

!INTENDED FOR DOMESTIC COOKING ONLY !

READ AND SAVE THESE INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGE 10.

In U.S.A., register your range hood online at www.broan.com

In Canada, register your range hood online at www.broan.ca

! WARNING

! WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any solid-state speed control device.

8.To reduce the risk of fire, use only metal ductwork.

9.This unit must be grounded.

10.When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN — You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels — This could cause a violent steam explosion.

4.Use an extinguisher ONLY if:

A.You own a Class ABC extinguisher and you know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department has been called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1.For indoor use only.

2.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

3.To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. off power unit.

4.Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.

5.The minimum hood distance above cooktop must not be less than 24". For best capture of cooking impurities, the bottom of the hood should be at a maximum of 30" above cooking surface.

6.Two installers are recommended because of the large size and weight of this unit.

7.To reduce the risk of fire and to properly exhaust air, be sure to duct air outside — Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.

8.Because of the high exhausting capacity of this unit, you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen.

9.To reduce the risk of fire and electrical shock, the Broan Elite EW48 Series models should only be installed with their own built-in blower.

10.When used in recirculation mode, to reduce the risk of fire and shock, use only conversion kit model ARKEW48.

11.Please read specification label on product for further information and requirements.

2

(1) DECORATIVE FLUE
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer. Make sure that the following items are included:
- Hood - Decorative flue assembly (lower and upper flues) - Upper flue mounting bracket
- Aluminum grease filter(s) (1 for 24-in. width hood, 2 for 30-in. and 36-in. width hoods)
- Installation instructions - Parts bag: 6 M4 x 38 Phillips 9 mm round head mounting screws,
2 M4 x 12 Phillips 9 mm round head screws,
2 washers and 3 wire connectors Parts sold separately: - Ducts, elbows, wall and roof caps. - Optional flue extension for ceilings of 9 ft. or more: models AEEW48SS (stainless steel), AEEW48BLS (black stainless steel) or AEEW48WH (white). - Non-duct kit model ARKEW48, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.
9. DUCT CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 10. PREPARE THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . . 8 11. INSTALL THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . 8-9 12. REINSTALL GREASE FILTER(S) . . . . . . . . . . . . . . . . . . . . . . . 9 13. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 14. CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 15. REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 16. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1. PREPARE INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. SELECT INSTALLATION TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. BUILD FRAMEWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY) 4 5. INSTALL PLENUM (NON-DUCTED INSTALLATION ONLY) . . . . . . . . . 4
6. REMOVE GREASE FILTER(S) . . . . . . . . . . . . . . . . . . . . . . . . . 5 7. INSTALL THE HOOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 8. CONNECT WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. SELECT INSTALLATION TYPE
HR0224A
(2) WASHERS
(3) WIRE CONNECTORS
ASSEMBLY
ROUND HEAD SCREWS
(2) M4 X 12 PHILLIPS
ROUND HEAD SCREWS
(6) M4 X 38 PHILLIPS
(1 OR 2) GREASE FILTER(S)
MOUNTING BRACKET
(1) UPPER FLUE
1. PREPARE INSTALLATION

TABLE OF CONTENTS

! WARNING

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

2.1 NON-DUCTED INSTALLATION

The ARKEW48 non-duct kit is required for a non-ducted installation.

2.2 DUCTED INSTALLATION

 

 

Plan where and how the ductwork will be installed.

ROOF CAP

6” ROUND

A straight, short duct run will allow the hood to perform most efficiently. Long duct

 

DUCT

 

 

runs, elbows and transitions will reduce the performance of the hood. Use as few

 

 

of them as possible. Larger ducting may be required for longer duct runs.

 

 

Install wall or roof cap. Connect 6” round metal ductwork to cap and work back

 

 

towards the hood location. Use 2” metal foil duct tape to seal the joints.

 

 

2.3 ALL INSTALLATIONS

DECORATIVE

WALL

The minimum hood distance above cooktop is 24”. A maximum of 30” above

FLUE

 

CAP

cooktop is recommended for best capture of cooking impurities.

 

 

Distances over 30” are at the installer and users discretion providing that ceiling

HOOD

6” ROUND

height and decorative flue length allow it.

 

ELBOW

 

 

NOTE: Ceilings of 9 ft. or more require flue extension model AEEW48SS (stainless

 

 

steel), AEEW48BLS (black stainless steel) or AEEW48WH (white).

24” MINIMUM ABOVE

 

 

 

 

COOKING SURFACE

 

 

HH0281A

 

3

Broan EW4824SS, EW4830SS, EW4830BLS, EW4830WH, EW4836SS INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

3. BUILD FRAMEWORK

!WARNING

When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.

When building framework, always follow all applicable construction codes and standards.

Construct wood wall framing that is even with the surface of wall studs.

Wood wall framing must be at least 1/2” thick and 3” high. Fasten wood wall framing to wall studs for a solid installation.

Make sure that the height of the framing will allow the retaining screws to be secured to the framing within the dimensions shown.

After wall surface is finished, using a level, draw a vertical line up to the ceiling starting from the center of the planned hood location. Measure and mark the retaining screw locations using the measurements given in illustration at right. Insert 2 M4 x 38 Phillips 9 mm round head mounting screws in wall framing; do not completely tighten the screws at this time.

WALL STUDS

FRAMING BEHIND DRYWALL

HD1151A

34 ¾” = BOTTOM OF HOOD 24” ABOVE COOKTOP

40 ¾” = BOTTOM OF HOOD 30” ABOVE COOKTOP

4. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY)

Center the upper flue mounting bracket with the center line previously drawn in step 3 and place it flush with the ceiling. Use the upper flue mounting bracket as a template to mark the position of its screws.

Secure the upper flue mounting bracket to the wall using 2 M4 x 38 Phillips 9 mm round head mounting screws. Make sure that the bracket is tight against the wall.

CEILING

 

 

CENTER OF INSTALLATION

 

UPPER FLUE MOUNTING

 

 

BRACKET SLOTS

MOUNTING BRACKET

 

C

HD1150

FLUSH WITH CEILING

L

 

 

 

5. INSTALL PLENUM (NON-DUCTED INSTALLATION ONLY)

Center the plenum with the center line previously drawn in step 3 and place it flush with the ceiling. Use the plenum mounting slots as a template to mark the position of its screws.

Secure the plenum to the wall using 2 M4 x 38 Phillips 9 mm round head mounting screws. Make sure that the plenum is tight against the wall.

 

CEILING

 

 

 

PLENUM

 

 

FLUSH WITH

 

PLENUM

CEILING

 

 

 

MOUNTING

 

 

SLOTS

 

 

C

CENTER OF

HD1158

L

INSTALLATION

 

 

4