BFT PHOBOS User Manual

4 (1)
BFT PHOBOS User Manual

PHOBOS

D811317 15-04-02 Vers. 03

ELECTROMECHANICAL AUTOMATION FOR SWING GATES

PHOBOS

Thank you for buying this product, our company is sure that you will be more than satisfied with the product’s performance. The product is supplied with a “Warnings” leaflet and an “Instruction booklet”. These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/EEC and 73/ 23/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.

The “Warnings” leaflet and “Instruction booklet” supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance.

Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.

Keep the instructions together with the technical brochure for future reference.

This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.

The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation.

Do not install the product in explosive atmosphere.

The construction components of this product must comply with the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments. As for all non-EEC countries, the abovementioned standards as well as the current national standards should be respected in order to achieve a good safety level.

The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.

The installation must comply with the provisions set out by the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.

148• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.

Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3mm.

Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.

Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal.

Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing.

Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure.

The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers’ components are used.

Only use original parts for any maintenance or repair operation.

Do not modify the automation components, unless explicitly authorised by the company.

Instruct the product user about the control systems provided and the manual opening operation in case of emergency.

Do not allow persons or children to remain in the automation operation area.

Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.

The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.

Anything which is not expressly provided for in the present instructions, is not allowed.

2) GENERAL OUTLINE

Electromechanical piston designed to automatically operate residential gates. The irreversible gearmotor keeps the gate locked both in the closing and opening positions, making the use of the electric lock redundant.

The actuator is not supplied with mechanical clutch. The unit is controlled by means of an electronic control board with torque adjustment. End-of- stroke operation is controlled by the control board.

3) TECHICAL SPECIFICATIONS

230V ±10% 50 Hz single-phase(*)

Power supply : .....................................

Motor revolutions : ....................................................................

2800 min -1

Absorbed power : ............................................................................

210 W

Capacitor : ........................................................................................

6.3 µF

Absorbed current : .............................................................................

0.8 A

Insulation level : ........................................................................................

F

Thermal protection : ...............................................

110 °C (self-resetting)

Push and pull force : .......................................................

2000 N (~200 kg)

Working stroke : .............................................................................

280 mm

Stem speed : .......................................................................

12 mm/s circa

Impact reaction : ...................................

Electronic clutch on control board

Manual manoeuvre : .......................................................

CLS release key

No. of manoeuvres in 24hours : ........................................

60 manoeuvres

Max. leaf length : .........................................................................

1800 mm

Max. leaf weight : ...........................................................

2500 N (~250 kg)

Environmental conditions : .....................................

from -20 °C to + 60 °C

Protection level : ................................................................................

IP 44

Dimensions : ...........................................................................

Vedere fig.1

Controller weight : ....................................................................

50N (~5kg)

Lubrication : ..................................................................

permanent grease

(*) Special supply voltages on request.

 

4) INSTALLATION OF THE ACTUATOR

4.1) Preliminary checks

Check that:

The gate structure is sufficiently sturdy.

Also make sure that the actuator pushes against the leaf reinforced section.

The leaves move manually and without effort all along their stroke.

The door stop plates are fitted at the end of both closing and opening strokes.

If the gate has not been recently installed, check the wear condition of all components.

Repair or replace faulty or worn parts.

The automation reliability and safety are directly influenced by the state of the gate structure.

The diagram in fig. 2 should be used as a reference for installation and consult the table for the distances in mounting the gate post.

The diagram in fig. 2 uses the following legend: P Gate post rear fastening bracket

F Front leaf fastening fork

a-b “P” bracket installation value

CDistance between fixing points (C = 993 mm)

DGate length

X

Distance from gate axis to the edge of the post

Z

Always over 45 mm (b - X)

kg

max. weight of leaf

α°

leaf opening in degrees

4.2) How to read the installation distance tables

Select “a” and “b” according to the angle in degrees α° that the gate has to open. The table shows the ideal value for “a” and “b” for an opening of α° = 90° at constant speed.

If there is too large a difference between “a” and “b”, the leaf will not travel smoothly and the pushing or pulling force will fluctuate during its stroke. To respect the opening speed and ensure the controller operates correctly, it is best to keep the difference between “a” and “b” as low as possible.

When “a” and “b” are at their maximum, the piston develops the maximum force.

4.3) Off-standard installations.

Fig. 3 shows an installation with a recess when there is not sufficient space between the leaf and perimeter wall.

When the leaf’s position does not allow for an “b” value listed in the table, the leaf’s hinge pivot can be shifted (fig. 4), or a recess can be made cut out of the actual gate-post (fig. 5).

4.4) Mounting the brackets to the gate-post and to the gate.

Fix the bracket “P” (fig. 6) to the gate-post with a good welding.

The fork “F” should be welded in the same way to the gate taking care that the actuator can then be mounted perfectly horizontal to the line of travel of the gate fig. 7.

If the gate operates on a slope (opening inwards with an uphill driveway), fig. 7 gives the maximum oscillations of the piston with respect to its horizontal.

• If the gate-post is in brick, the plate “PF” must be set soundly into the post

D811317_03

AUTOMATION FOR SWING GATES

PHOBOS

using adequately sized cramps “Z” welded to the back of the plate (fig. 8).

If the gate-port is in stone and the gate is small, the plate “PF” can be mounted with four metal expansion plugs “T” (fig. 9). If a larger gate is being installed it would be better to use a corner plate “PF” (fig. 10).

5) GROUND GATE STOPS

For the controller to operate correctly the gate stop “FA” must be used both in opening and closing, as shown in fig. 11.

6) THE ELECTRICAL PLANT SET-UP

Lay out the electrical installation (fig. 12) with reference to the CEI 64-8 and

IEC 364 provisions, complying with the HD 384 and other national standards in force for electrical installation.

The mains power supply connections must be kept totally separate from the service connections (photocells, electric edges, control devices etc.).

WARNING! For connection to the mains, use a multipolar cable with a minimum of 3x1.5mm2 cross section and complying with the previously mentioned regulations. For example, if the cable is out side (in the open), it has to be at least equal to H07RN-F, but if it is on the inside (or outside but placed in a plastic cable cannel) it has to be or at least egual to H05VV-F with section 3x1.5mm2.

Connect the control and safety devices in compliance with the previously mentioned electrical installation standards.

Fig.12 shows the number of connections and the cross section for power supply cables having a length of approximately 100 metres; in case of longer cables, calculate the cross section for the true automation load.

When the auxiliary connections exceed 50-metre lengths or go through critical disturbance areas, it is recommended to decouple the control and safety devices by means of suitable relays.

The main automation components are (fig.12):

IType-approved omnipolar circuit breaker with at least 3mm contact opening, provided with protection against overloads and short circuits,

 

suitable for cutting out automation from the mains. If not already

 

installed, place a type-approved differential switch with a 0.03A

 

threshold in the circuit just before the automation system.

Qr Control panel and incorporated receiver.

SPL

Heater board for operation at temperatures below 10°C (optional)

S

Key selector

 

AL

Blinker tuned in with antenna

 

M

Controller

 

Fte

Pair of outside photocells (transmitters)

Fre

Pair of outside photocells (receivers)

Fti

Pair of inside photocells with

column (transmitters)

Fri

Pair of inside photocells with

column (receivers)

T

1-2-4 channel transmitter

 

RG58 Antenna cable

For the connection from the controller to the control board, four cables have been provided having the following functions (Fig.14):

black

operation 1

blue

common

brown

operation 2

yellow/green

ground (GND)

Warning! For actuator wiring and accessory connection, refer to the relevant instruction manuals. The control panels and accessories must be suitable for use and conform to current standards.

Should the opening or closing direction be incorrect, it is possible to invert the connections of operation 1 and operation 2 (black/brown) on the control board.

The first command after an interruption of the power supply should be an opening manoeuvre.

The cable sections and numbering are indicated in the diagram (fig. 12). For distances of over 100 meters, the cable section must be increased. All metal masses in the housings of equipment and automation must be earthed.

7) ADJUSTING THE PUSHING FORCE

WARNING: Check that the impact force value measured at the

The pushing force is calibrated by means of the torque regulator in the control unit. The optimum torque must allow a complete opening or closing cycle with the minimum force necessary. An excessive torque can reduce the anti-crush safety. In the other case, an insufficient torque can impede the manoeuvres. Consult the control unit’s instruction manual.

8) ADJUSTMENT OF THE LIMITING DEVICES

The correct adjustment of the limiting devices is obtained by setting the working time on the control board correctly. Refer to the instructions of the control board.

9) MANUAL OPENING

All controllers feature a key release mechanism. After lifting the lock cover

(fig.13), insert the release key supplied and turn it clockwise by 90°. Push the leaf manually to open the gate. To reset the motorised operation, turn the key in the opposite direction and refit the cover.

10) COVERS

An optional stem cover (mod.CPH) is available on request in order to protect the stem and to improve the appearance of the actuator. The actuator equipped with the stem cover mod. CPH looks like in fig.15.

The stem cover is mounted on the right or left actuator by simply inverting the position of the cover and making sure that the water drain outlet is directed downwards.

11) CHECKING THE AUTOMATION

Before considering the automation completely operational, the following checks must be made with great care:

Check that all the components are firmly anchored.

Control all the safeties work properly (i.e. photocells, pneumatic skirt, etc.).

Check the emergency manoeuvre control.

Check the opening and closing manoeuvres using the controls.

Check the control unit’s electronic logic in normal (or customised) operation.

12) USE OF THE AUTOMATION

Since the automation may be remote controlled either by radio or a Start button, it is essential that all safeties are checked frequently.

Any malfunction should be corrected immediately by a qualified specialist. 149 Keep children at a safe distance from the field of action of the automation.

13) THE CONTROLS

With the automation the gate has a power driven opening and closing. The controls can come in various forms (i.e. manual, remote controlled, limited access by magnetic badge, etc.) depending on needs and installation characteristics. For details on the various command systems, consult the specific instruction booklets.

Anyone using the automation must be instructed in its operation and controls.

14) MAINTENANCE

When carrying out maintenance operation on the controller, disconnect it from the mains power supply. The actuator does not require periodical maintenance operations.

Check the safety devices of the gate and automation.

Periodically check the pushing force and correct the value of the electric torque in the control board if necessary.

In case of unsolved operation failures, disconnect the unit from the mains power supply and ask for the intervention of qualified personnel

(installer).

When the unit is out of order, activate the manual release to perform manual opening and closing manoeuvres.

15) NOISE

The aerial noise produced by the gearmotor under normal operating conditions is constant and does not exceed 70dB(A).

16) SCRAPPING

Materials must be disposed of in conformity with the current regulations. In case of scrapping, the automation devices do not entail any particular risks or danger. In case of recovered materials, these should be sorted out by type (electrical components, copper, aluminium, plastic etc.).

17) DISMANTLING

AUTOMATION FOR SWING GATES