Atec SH-641 User Manual

4.5 (2)

Bench-Top Type Temperature

(& Humidity) Chamber

SH SU

CAT.NO.E01111-K1209

Compact design for personal use, to network with your computer.

The Bench-top Type Temperature (& Humidity) Chamber Series features environmental testing performance in a compact design. Available in 20L and 60L capacities, these models offer temperature ranges as low as 20, 40, or 60 , and achieve excellent performance rates, as well as communication interface compatibilities to collect test data.

Espec offers you the best in terms of advanced testing equipment.

1

Atec SH-641 User Manual

 

 

* The viewing window is optional.

2

 

 

 

 

Characteristics

Stacked chambers (on stands)

Test area (60L model)

Full variation to select from

With its 3 temperature range patterns (to 60, 40 or 20 ), and 2 volumes (20 and 60L) selection, the Bench-top chambers offer 10 models in temperature or temperature/ humidity configuration, to fulfill customers' needs.

Light and small structure

The chamber structure is optimized to save space while offering a wide test area (22.5L for 1st model). Its relatively light weight allows set up almost everywhere.

Full-size chamber performance in a compact design

The SH-661 model achieves 60 to150 temperature range and 30 to 95 rh for humidity in a small structure. It shows undoubtedly better performance than any other previous bench-top model.

A refrigeration system that reduces energy consumption by 55%

Our exclusive refrigerator system with capacity control achieves 55 reduction in power consumption compared to our previous model. (SH/SU-221 241 models)

Easy wiring access

The chamber features free access to the test area. Cable ports are provided on both right and left side to allow easy wiring of specimens for measurement or voltage application.

3

Characteristics

Layout arrangement thanks to additional stand (option)

L and H stands are equipped with casters, and allow easy storage to optimize your testing zone. L stand is lower to fit under H stand and stack chambers. (L=Low, H=High)

*It is recommended to secure stands to the floor with provided anchor bolts.

Easy water supply

Water is supplied from the front side tank (equipped with a level sensor). Auxiliary water tank circuit (option) is also available for extended operation time. (SH model)

Right-opening door (option)

The door opening can be reversed to fit your installation space.

Viewing window (option)

An optional viewing window can be added to check specimens and wiring during testing.

(W215×H215m m for 20L model,

W215×H315mm for 60L model)

*Standard performance of the chamber will not be met when adding this option.

Stands (option)

Water supply tank

Right-opening door (option)

Viewing window (option)

4

Loading...
+ 11 hidden pages