TP04310A
Mobile Temperature System for testing components, hybrids, parts, modules, subassemblies and printed circuit boards at precise temperature
TEMPERATURE PERFORMANCE AND AIRFLOW CAPACITY
Temperature Range: |
|
+125° to -55°C: approximately 10 seconds or less |
|
1,3 |
-80° to +225°C (60 Hz System) |
|
|
-75° to +225°C (50 Hz System) |
Typical Temperature Transition Rate (air)1,2 |
-55° to +125°C: approximately 10 seconds or less |
|
|
|
|
System air flow output |
|
2.4 to 9 liters/second (5 to 18 scfm) CONTINUOUS |
|
|
|
Temperature accuracy |
|
1.0°C (when calibrated against NIST transfer |
|
|
|
Temperature set, display and resolution |
± 0.1°C |
|
|
|
|
Temperature Control: |
Control to within ± 0.1°C; SELF-TUNING available in DUT Control |
|
DUT Sensor Ports |
Type T and Type K Thermocouple ports standard |
|
DUT Control |
|
|
Remote interface ports |
|
IEEE-488, RS232C Serial, and Start Test/End of Test/Stop |
|
|
on First Fail (ST/ET/SFF) |
|
|
|
1Note: Ultimate low temperature and system performance may vary under operating conditions less than or greater than nominal. 2Note: Transition performed under nominal operating conditions.
3Note: Low temperature extremes can be achieved at reduced airflow rates.
|
|
|
|
|
|
|
USER FEATURES |
|
test programs may be created |
||||
|
Modes of Operation |
|
Two: Manual and Program Modes |
|||
|
Test set-up configurations |
|
12 Manual Mode test programs and 12 Program Mode |
|||
|
|
|
|
|
|
|
|
Test set-up storage |
|
11 Manual Mode test programs, 11 Program Mode |
|
|
|
|
|
|
test programs and 11 affiliated “Define Parameters” |
|
|
|
|
|
|
test set-ups can be stored for later recall. |
|
|
|
|
|
|
|
|
|
|
|
Ramp/soak/cycle configurations |
|
In Program Mode, up to 12 sequences per test set-up; |
|
|
|
|
|
|
table is displayed on-screen |
|
|
|
|
|
|
|
|
|
|
|
DUT temperature control |
|
Patented4 Dual Loop Temperature Control |
|
|
|
|
|
|
|
|
|
|
|
Status indicators |
|
Real-time status displayed on-screen and via remote |
|
|
|
|
|
|
interface |
|
|
|
|
|
|
|
|
|
|
|
Purge flow tester interface |
|
Dry air purge protects tester electronics |
|
|
|
|
protection |
|
from condensation |
|
|
|
|
|
|
|
|
|
|
|
Purge flow capacity |
|
0.25 to 1.5 liters per second (0.5 to 3 scfm) airflow |
|
|
|
|
|
|
|
|
|
|
|
Calibration |
|
Automated, simplified and accurate for all airflows |
|
|
|
|
|
|
and DUT types |
|
|
|
|
|
|
|
|
|
|
|
Thermal head raising and lowering |
|
Pneumatic control on thermal head, |
|
|
|
|
|
|
operated manually or via remote interface |
|
|
|
|
|
|
|
|
|
|
|
Head positioner movement |
|
Manual locking (4 locks), 360° head rotation; head |
|
|
|
|
|
|
can be manually pivoted, turned, tilted and vertically |
|
|
|
|
|
|
swung for ease of interface at tester site. |
|
|
|
|
|
|
|
|
|
|
|
Manipulator (arm) movement |
|
Motorized raising and lowering of arm; |
|
|
|
|
|
|
330° positioning range around the base unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
4Note: US Patent no. 4,734,872 |
|||
|
|
|
|
|
|
|
Part No. SL10290 R/C
Specifications System ®ThermoStream TP04310A Model