ORDER NO.PHAMOS0501005A7
E1
Microwave Oven
NN-P994SFR
NN-P994BFR
NN-P994WFR NN-T995
NN-T985SF NN-T975SF
NN-T965SF NN-T955SF
NN-T945SF NN-T935SF
NN-T994SFR NN-T964SFR
NN-H965 NN-S955
NN-H935 NN-S935
NN-S954BFR NN-S954WFR
NN-S934BFR NN-S934WFR
APH(USA)
CPH(CANADA)
RPH(Mexico/Latin American)
Please file and use this specified manual together with the service manual for Model NN-T695 (ORDER NO. PHAMOS0501001C1).
© 2005 Panasonic Home Appliances Microwave Oven (Shanghai) Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.
NN-P994SFR / NN-P994BFR
2
NN-P994SFR / NN-P994BFR
3
NN-P994SFR / NN-P994BFR
CONTENTS
|
|
Page |
1 |
SCHEMATIC DIAGRAM |
5 |
|
1.1. APH |
5 |
|
1.2. CPH |
6 |
|
1.3. RPH |
7 |
2 |
MEASUREMENTS AND ADJUSTMENTS |
8 |
|
2.1. Adjustment of primary latch switch, secondary latch switch |
|
|
and short switch. |
8 |
|
2.2. Measurement of microwave output |
8 |
3 |
PROCEDURE FOR MEASURING MICROWAVE ENERGY |
|
|
LEAKAGE |
9 |
|
3.1. Equipment |
9 |
|
3.2. Procedure for measuring radiation leakage |
9 |
|
3.3. Record keeping and notification after measurement |
9 |
|
3.4. At least once a year, have the radiation monitor checked |
|
|
for calibration by its manufacturer. |
9 |
4 |
SIMPLE WAY OF H.V. INVERTER/MAGNETRON |
|
|
TROUBLESHOUTING |
10 |
5 |
EXPLODED VIEW AND PARTS LIST |
11 |
|
Page |
5.1. EXPLODED VIEW |
11 |
5.2. PARTS LIST |
12 |
5.3. WIRING MATERIALS |
13 |
5.4. ESCUTCHEON BASE ASSEMBLY |
14 |
5.5. PACKING AND ACCESSORIES |
20 |
5.6. DOOR ASSEMBLY |
21 |
6 DIGITAL PROGRAMMER CIRCUIT |
22 |
6.1. P994*FR APH/CPH |
22 |
6.2. NN-T995SF APH/CPH, T995SF/SM RPH, T985SF APH 24 |
|
6.3. NN-T955SF APH, T994SFR APH |
26 |
6.4. NN-T975SF/T965SF/T945SF/T935SF APH, T964SFR |
|
APH |
28 |
6.5. NN-H965 APH/CPH, H935 APH |
30 |
6.6. NN-S935 APH |
32 |
6.7. NN-S955 RPH, S934*FR APH |
34 |
6.8. NN-S955 APH, S954*FR APH |
36 |
6.9. PARTS LIST |
38 |
4
NN-P994SFR / NN-P994BFR
1 SCHEMATIC DIAGRAM
1.1.APH
5
NN-P994SFR / NN-P994BFR
1.2.CPH
6
NN-P994SFR / NN-P994BFR
1.3.RPH
7
NN-P994SFR / NN-P994BFR
2 MEASUREMENTS AND ADJUSTMENTS
2.1.Adjustment of primary latch switch, secondary latch switch and short switch.
1.Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL.
NOTE:
No specific individual adjustments during installation of the Primary latch switch, Secondary latch switch or Short switch to the door hook are required.
2.When mounting the door hook assembly to the oven assembly, adjust the door hook assembly by moving it in the direction of the arrows in the illustration so that the oven door will not have any play in it. Check for play in the door by pulling the door assembly. Make sure that the latch keys move smoothly after adjustment is completed. Completely tighten the screws holding the door hook assembly to the oven assembly.
3.Reconnect the short switch and check the continuity of the monitor circuit and all latch switches again by following the component test procedures.
2.2.Measurement of microwave output
The output power of the magnetron can be determined by performing IEC standard test procedures. However,due to the complexity of IEC test procedures, it is recommended to test the magnetron using the simple method outlined below.
Necessary Equipment:
*1 liter beaker *Glass thermometer *Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will lower the magnetron output. Take the temperature readings and heating time as accurately as possible.
1.Fill the beaker with exactly one liter of tap water.Stir the water using the thermometer and record the water’s temperature. (recorded as T1).
2.Place the beaker on the center of glass tray.
Set the oven for High power and heat it for exactly one minute.
3.Stir the water again and read the temperature of the water. (recorded as T2).
4.The normal temperature rise at High power level for each model is as shown in table.
TABLE (1L-1min.test)
RATED OUTPUT |
TEMPERATURE RISE |
1200W |
Min. 18.5°F(10.3°C) |
1300W |
Min. 19.8°F(11.1°C) |
8
NN-P994SFR / NN-P994BFR
3PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE
3.2.1.Measurement with the outer panel removed.
Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measuring around the magnetron.
NOTE:
The U.S. Government standard is 5 mW/cm2 while in the customer’s home. 2mW/cm2 stated here is our own voluntary standard. (1mW/cm2 for Canada)
3.1.Equipment
•Electromagnatic radiation monitor
•Glass thermometer 212°F or 100°C
•600cc glass beaker
3.2.Procedure for measuring radiation leakage
Note before measuring.
•Do not exceed meter full scale deflection. Leakage monitor should initially be set to the highest scale.
•To prevent false readings the test probe should be held by the grip portion of the handle only and moved along the shaded area in Figure no faster than 1 inch/sec (2.5cm/sec).
•Leakage with the outer panel removed ...... less than 5mW/cm2.
•Leakage for a fully assembled oven with door normally
closed ...... |
less than 2mW/cm 2 (1mW/cm 2 for Canada). |
•Leakage for a fully assembled oven [Before the latch switch
(primary) is interrupted] while pulling the door ...... less than 2mW/cm 2.
1.Pour 275 ± 15cc (9ozs s± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a beaker which is graduated to 600cc, and place in the center of the oven.
2.Set the radiation monitor to 2450MHz and use it following the manufacturer´s recommended test procedure to assure correct results.
3.When measuring the leakage, always use the 2 inch (5cm) spacer supplied with the probe.
4.Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured.
3.2.2.Measurements with a fully assembled oven.
After all components, including outer panel are fully assembled, measure for radiation leakage around the door periphery, the door viewing window, the exhaust opening and air inlet openings.
3.3.Record keeping and notification after measurement
•After any adjustment or repair to a microwave oven, a leakage reading must be taken. Record this leakage reading on the repair ticket even if it is zero.
A copy of this repair ticket and the microwave leakage reading should be kept by repair facility.
•Should the radiation leakage be more than 2 mW/cm2 (1mW/cm for Canada) after determining that all parts are in good condition, functioning properly, and genuine replacement parts as listed in this manual have been used, immediately notify PASC, PSC or PCI.
3.4.At least once a year, have the radiation monitor checked for calibration by its manufacturer.
9
NN-P994SFR / NN-P994BFR
4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOUTING
Purpose:
Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure.
Power will: |
|
Ammeter reading is: |
|
To do: |
Remedy: |
|
Shut off in 23 seconds |
1. |
Between 0.5A and 1.0A. |
Check and repair open magnetron circuit |
Open magnetron wiring between Inverter |
||
after “Start”. |
|
|
|
|
|
and magnetron terminal. |
|
|
|
|
|
|
|
|
|
2. |
Between 1.0A and 2.0A. |
Check continuity of D702 in Inverter PCB. |
|
|
|
|
|
|
|
|
|
|
|
|
|
1. |
D702 shorted |
Replace H.V.Inverter |
|
|
|
|
|
|
(F606Y6G00AP/F606Y6G00CP) |
|
|
|
|
2. |
D702 is OK |
Replace magnetron |
Shut off in 3 |
seconds |
1. |
Less than 0.5A |
Check open circuit: Latch Switch, DPC, |
Replace defective component(s), or |
|
after “Start” |
|
|
|
Power Relay and CN701 |
correct switch, cables and connectors. |
|
|
|
|
|
|
|
|
10
NN-P994SFR / NN-P994BFR
5 EXPLODED VIEW AND PARTS LIST
5.1.EXPLODED VIEW
11
NN-P994SFR / NN-P994BFR
5.2.PARTS LIST
NOTE:
1.When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part.
2.Important safety notice:
Components identified by mark have special characteristics important for safety.
When replacing any of these components, use only manufacture’s specified parts.
NOTE:
“A” parts are supplied by CSD (Japan) “F” parts are supplied by PHAMOS (China)
Ref. No. |
|
Part No. |
Part Name & Description |
Pcs/Set |
Remarks |
1 |
|
F00064W70AP |
CAUTION LABEL |
1 |
P994*FR APH,T9*5SF APH,T9*4SFR APH |
1 |
|
F00069660AP |
CAUTION LABEL |
1 |
H9*5 APH,S9*5 APH,S9*4BFR/WFR APH, |
|
|
|
|
|
T995SF/SM RPH,S955WF/WM RPH |
1 |
|
F00067600CP |
CAUTION LABEL |
1 |
CPH |
2 |
|
F00077B00BAP |
NAME PLATE |
1 |
H965BF APH |
2 |
|
F00077B00HAP |
NAME PLATE |
1 |
H965WF APH |
2 |
|
F00077E30BAP |
NAME PLATE |
1 |
H935BF APH |
2 |
|
F00077E30HAP |
NAME PLATE |
1 |
H935WF APH |
2 |
|
F00077B20BAP |
NAME PLATE |
1 |
S955BF APH |
2 |
|
F00077B20HAP |
NAME PLATE |
1 |
S955WF APH |
2 |
|
F00077B40BAP |
NAME PLATE |
1 |
S935BF APH |
2 |
|
F00077B40HAP |
NAME PLATE |
1 |
S935WF APH |
2 |
|
F00077B10BAP |
NAME PLATE |
1 |
S954BFR APH |
2 |
|
F00077B10HAP |
NAME PLATE |
1 |
S954WFR APH |
2 |
|
F00077E40BAP |
NAME PLATE |
1 |
S934BFR APH |
2 |
|
F00077E40HAP |
NAME PLATE |
1 |
S934WFR APH |
2 |
|
F00077B30HRP |
NAME PLATE |
1 |
S955WF RPH |
3 |
|
F00337D00AP |
FUSE LABEL |
1 |
APH,CPH |
3 |
|
F00337D00RP |
FUSE LABEL |
1 |
RPH |
4 |
|
F10016G10AP |
BASE |
1 |
|
5 |
|
F10084T00AP |
RUBBER FOOT |
4 |
|
6 |
|
F110D6G10SAP |
CABINET BODY |
1 |
P994SFR |
6 |
|
F110D6G20BAP |
CABINET BODY |
1 |
P994BFR |
6 |
|
F110D6G20HAP |
CABINET BODY |
1 |
P994WFR |
6 |
|
F110D5W10SAP |
CABINET BODY |
1 |
T995SF APH/CPH,T995SF/SM RPH, |
|
|
|
|
|
T975SF APH,T965SF APH,T9*4SFR APH |
6 |
|
F110D4U50SAP |
CABINET BODY |
1 |
T985SF APH,T955SF APH,T945SF APH,T935SF APH |
6 |
|
F110D5W20BAP |
CABINET BODY |
1 |
H9*5BF,S9*5BF,S9*4BFR |
6 |
|
F110D5W20HAP |
CABINET BODY |
1 |
H9*5WF,S9*5WF,S9*4WFR |
7 |
|
F200A5W20AP |
OVEN |
1 |
P994*FR,T9*5SF/SM,T9*4SFR APH,H9*5 |
7 |
|
F200A5W30AP |
OVEN |
1 |
S9*5,S9*4BFR/WFR |
8 |
|
F20555K00AP |
COVER |
1 |
|
9 |
|
F21315Y00AP |
PULLY SHAFT |
1 |
|
10 |
|
F2177-F80 |
WASHER |
1 |
|
11 |
|
F290D9330AP |
ROLLER RING (U) |
1 |
|
12 |
|
F3020-1200 |
DOOR HOOK |
1 |
|
14 |
|
F3136-1200 |
HOOK LEVER A |
1 |
|
15 |
|
F31374650AP |
HOOK LEVER B |
1 |
|
16 |
|
F31384650AP |
HOOK LEVER C |
1 |
|
17 |
|
F400A5Y00AP |
FAN MOTOR |
1 |
AC120V,SINGLE PHASE,60Hz |
18 |
|
F40084T00AP |
FAN BLADE |
1 |
|
19 |
|
F40254W00AP |
AIR GUIDE A |
1 |
|
20 |
|
F40264T60AP |
AIR GUIDE B |
1 |
|
21 |
|
F41445W00AP |
ORIFICE |
1 |
|
22 |
|
F64508660AP |
SENSOR COVER B |
1 |
P994*FR,T9*5SF/SM,T9*4SFR APH,H9*5 |
24 |
|
F65434W00AP |
SENSOR COVER C |
1 |
P994*FR,T9*5SF/SM,T9*4SFR APH,H9*5 |
25 |
|
A607S4M00AP |
STEAM SENSOR |
1 |
P994*FR,T9*5SF/SM,T9*4SFR APH,H9*5 |
26 |
|
F612E4W00AP |
INCANDESCENT LAMP (U) |
1 |
125V,60Hz,20W |
27 |
|
J61424T00AP |
MICRO SWITCH |
1 |
(PRIMARY LATCH SWITCH)(V-15G-3C25) |
28 |
|
J61414T00AP |
MICRO SWITCH |
1 |
(SECONDARY LATCH SWITCH)(D3V-16G-3C25) |
29 |
|
F61456N60AP |
THERMAL CUTOUT |
1 |
150°C/-20°C |
31 |
|
J61784T00AP |
MICRO SWITCH |
1 |
(SHORT SWITCH)(D3V-1G-2C25) |
32 |
|
F606Y6G00AP |
H.V.INVERTER (U) |
1 |
APH,RPH |
32 |
|
F606Y6G00CP |
H.V.INVERTER (U) |
1 |
CPH |
33 |
|
F65856K50AP |
INVERTER BRACKET |
1 |
|
34 |
|
2M261-M32F |
MAGNETRON |
1 |
APH,RPH |
34 |
|
2M261-M32J |
MAGNETRON |
1 |
CPH |
35 |
|
F62307A00AP |
FUSE |
1 |
20A |
36 |
|
F62315G10XN |
FUSE HOLDER |
1 |
RPH |
12
|
|
|
|
|
|
NN-P994SFR / NN-P994BFR |
|
|
|
|
|
|
|
|
|
Ref. No. |
|
Part No. |
Part Name & Description |
Pcs/Set |
Remarks |
|
|
37 |
|
J692Y7D00AP |
NOISE FILTER |
1 |
APH |
|
|
37 |
|
J692Y4T00CPR |
NOISE FILTER |
1 |
CPH |
|
|
38 |
|
F63265G60AP |
TURNTABLE MOTOR |
1 |
|
|
|
39 |
|
F900C4T60CP |
AC CORD W/PLUG |
1 |
P994*FR APH,T9*5SF APH,T9*4SFR APH |
|
|
39 |
|
F900C4T00AP |
AC CORD W/PLUG |
1 |
H9*5 APH,S9*5 APH,S954*FR APH,S934*FR APH, |
|
|
|
|
|
|
|
T995 RPH,S955 RPH |
|
|
39 |
|
F900C4W10CP |
AC CORD W/PLUG |
1 |
CPH |
|
|
40 |
|
F66626G10AP |
GROUNDING PLATE |
1 |
|
|
|
41 |
|
XTWFA4+12T |
SCREW |
4 |
FOR MAGNETRON |
|
|
42 |
|
F90804W00AP |
CANOE CLIP |
1 |
FOR COVER |
|
|
43 |
|
XTTANE4T12A0 |
SCREW |
5 |
FOR CABINET BODY |
|
|
44 |
|
XTTFA4+8BFZ |
SCREW |
2 |
FOR CABINET BODY SIDE |
|
|
|
|
|
|
|
(P994BFR,H9*5BF,S9*5BF,S9*4BFR) |
|
|
44 |
|
XTTFA4+8BCR |
SCREW |
2 |
FOR CABINET BODY SIDE |
|
|
|
|
|
|
|
(P994SFR/WFR,T9*5SF/SM,T9*4SFR,H9*5WF,S9*5WF, |
|
|
|
|
|
|
|
S9*4WFR) |
|
|
46 |
|
F02445Y00AP |
CAUTION LABEL |
1 |
P994SFR,T995SF/SM,T975SF,T965SF,T9*4SFR APH |
|
|
47 |
|
F03347B60AP |
MENU LABEL |
1 |
T995SF APH,T985SF APH |
|
|
47 |
|
F03347B60CP |
MENU LABEL |
1 |
T995SF CPH |
|
|
47 |
|
F03347B60RP |
MENU LABEL |
1 |
T995SF/SM RPH |
|
|
47 |
|
F03347D60AP |
MENU LABEL |
1 |
H965BF/WF APH,H935BF/WF APH |
|
|
47 |
|
F03347D60CP |
MENU LABEL |
1 |
H965BF/WF CPH |
|
|
47 |
|
F03346L20AP |
MENU LABEL |
1 |
S935BF/WF APH |
|
|
47 |
|
F03347G50RP |
MENU LABEL |
1 |
S955WF/WM RPH |
|
|
48 |
|
F82575W00AP |
DOOR OPENING BRACKET |
1 |
P994*FR,T955SF,T994SFR APH, |
|
|
|
|
|
|
|
H965 APH/CPH,H935 APH,S935 APH |
|
|
48 |
|
F82574U00AP |
DOOR OPENING BRACKET |
1 |
T995SF/SM,T985SF,T975SF,T965SF,T945SF, |
|
|
|
|
|
|
|
T935SF,T964SFR APH,S954*FR APH, |
|
|
|
|
|
|
|
S934*FR APH,S955 APH/RPH |
|
|
49 |
|
F04467D00AP |
FUNCTION LABEL |
1 |
T995SF APH,T985SF APH |
|
|
49 |
|
F04467D00CP |
FUNCTION LABEL |
1 |
T995SF CPH |
|
|
49 |
|
F04467D00RP |
FUNCTION LABEL |
1 |
T995SF/SM RPH |
|
|
50 |
|
F00066G00RP |
CAUTION LABEL |
1 |
T995SF/SM RPH |
|
|
51 |
|
F11406G00AP |
LEVER STOPPER |
1 |
P994*FR,H965 APH/CPH,H935 APH,S935 APH |
|
|
52 |
|
F00167D00AP |
CAUTION LABEL |
1 |
T995SF APH,T985SF APH |
|
5.3.WIRING MATERIALS
Ref. No. |
|
Part No. |
Part Name & Description |
Pcs/Set |
Remarks |
W1 |
|
F030A7B60AP |
LEAD WIRE HARNESS |
1 |
APH |
W1 |
|
F030A7B60CP |
LEAD WIRE HARNESS |
1 |
CPH |
W1 |
|
F030A6P40AG |
LEAD WIRE HARNESS |
1 |
RPH |
W2 |
|
F030E6G30AP |
H.V.LEAD WIRE |
1 |
APH,RPH |
W2 |
|
F030E6G30CP |
H.V.LEAD WIRE |
1 |
CPH |
13