AC/DC External Desktop
|
|
|
|
110 Watts |
XPiQ inc. |
||
PUP110 Series |
Intelligent Design Quality Product |
||
|
|
||
|
|
|
|
• |
Built-in EMI Filter |
|
|
|
|
• |
|
|
|
International Safety Approvals |
|
|
|
with CE Mark |
|
|
|
• |
|
|
|
100% Burn-In |
|
|
|
• |
|
|
|
3000 VAC Isolation |
|
|
|
• |
|
|
|
Input Surge Protection |
|
|
|
• |
|
|
|
Wide Input Voltage 85 to 264 VAC |
|
|
|
|
|
Specification
All specifications typical at nominal line, full load and 25°C
Input
Input Voltage |
• |
85-264 VAC |
Input Frequency |
• |
47 to 440 Hz |
Input Current |
• |
3.20 A (rms) for 115 VAC |
|
|
1.80 A (rms) for 230 VAC |
Output
Output Voltage |
• |
See Tables |
Output Current |
• |
See Tables |
Ripple and Noise |
• |
1% pk-pk max |
Overvoltage |
• |
Provided on output #1 only |
Protection |
|
set at 112-132% of its nominal |
|
|
output voltage |
Overcurrent |
• |
All outputs protected to short |
Protection: |
|
circuit conditions |
Temperature |
• |
All outputs ±0.04%/°C |
Coefficient: |
|
maximum |
Power Fail Detect |
• |
TTL logic high for normal |
(optional) |
|
operation and TTL logic low |
|
|
upon loss of input power. This |
|
|
signal appears at least 1 ms prior |
|
|
to +5 V output dropping 5% below |
|
|
its nominal value. This signal also |
|
|
provides a minimum delay of |
|
|
100 ms after +5 V is within |
|
|
regulation |
General
Efficiency |
• |
62% minimum at 110 W output |
|
Hold-up time |
• |
12 msec minimum |
|
Line Regulation |
• |
±0.5% maximum at full load |
|
Inrush Current |
• |
15 |
A at 115 VAC or |
|
|
30 |
A at 230 VAC at +25 °C cold start |
Withstand Voltage |
• |
3000 VAC from input to output |
|
|
|
1500 VAC from input to ground |
|
|
|
500 VAC from output to ground |
|
Insulation Resistance |
• |
10 |
Mohm minimum from |
|
|
output to ground |
Environmental
Operating |
• |
0 °C to +70 °C derate linearly from |
Temperature |
|
100% load at +50 °C to 50% load |
|
|
at +70 °C |
Storage |
• |
-40 °C to +85 °C |
Temperature |
|
|
MTBF |
• |
100,000 hours minimum at full load |
|
|
at +25 °C ambient |
EMC & Safety
EMI Requirements |
• |
Meets conducted limits of |
|
|
FCC 20780 Level B, CISPR 22 |
|
|
(EN 55022) Level B |
Safety Requirements |
• |
Approved to: |
|
|
a) UL 1950 |
|
|
b) CSA C22.2 No. 234 |
|
|
c) IEC 950 |
• |
|
PH: 508 |
429.9883 |
• |
||
|
||||||
|
||||||
|
|
|
|
|
||
|
|
|
|
FAX: 800 |
226.2100 |
|
|
www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
|
Holliston, MA 01746 USA |
|
||
|
|
|
|