AC/DC Medical Open Frame
|
|
|
|
65 Watts |
XPiQ inc. |
||
PM65 Series |
Intelligent Design Quality Product |
||
|
|
||
|
|
|
|
• |
4000 VAC Isolation |
|
|
• |
|
||
|
|
100% Burn-in |
|
|
|
• |
|
|
|
Low Safety Leakage Current |
|
|
|
• |
|
|
|
Wide Input Voltage 85 to 264 VAC |
|
|
|
• |
|
|
|
Meets EMI Requirements of |
|
|
|
Medical Equipment |
|
|
|
• |
|
|
|
Both Line and Neutral Fused for |
|
|
|
European Requirements |
|
|
|
|
|
Specification
Input
Input Voltage |
• |
85 to 264 |
VAC |
Input Frequency |
• |
47 to 440 |
Hz |
Input Current |
• |
1.6 A (rms) for 115 VAC |
|
|
|
1.0 A (rms) for 230 VAC |
|
Safety Ground |
• |
50 µA max at 110 VAC 60 Hz |
|
Leakage Current |
• |
100 µA max at 240 VAC 50 Hz |
Output
Total output power: |
• |
0 to 65 watts |
Ripple and noise: |
• |
1% pk-pk maximum |
Overvoltage |
• |
Provided on output #1 only; |
Protection: |
|
set at 112-132% of its nominal |
|
|
output voltage |
Overcurrent |
• |
All outputs protected to short |
Protection: |
|
circuit conditions |
Temperature |
• |
All outputs ±0.04%/°C |
Coefficient: |
|
maximum |
Transient Response |
• |
Maximum excursion of 4% or |
|
|
better on all models, recovering |
|
|
to 1% of final value 500 µs after |
|
|
a 25% step load change |
Line Regulation |
• |
±0.5% max at full load |
General
Efficiency |
• |
70% minimum at 65 watt output |
Hold-up time |
• |
10 msec minimum at nominal input |
Inrush Current |
• |
15 A at 115 VAC or 30 A at |
|
|
230 VAC at +25 °C cold start |
Withstand Voltage |
• |
4000 VAC from input to output |
|
|
1500 VAC from input to ground |
|
|
500 VAC from output to ground |
Insulation Resistance |
• |
10 Mohm minimum from |
|
|
output to ground |
Switching Frequency |
• |
32 kHz (±5 kHz) |
Environmental
Operating |
• |
0 °C to +70 °C, derate linearly from |
Temperature |
|
100% load at +50 °C to 50% load |
|
|
at +70 °C |
Storage |
• |
-40 °C to +85 °C |
Temperature |
|
|
Relative Humidity |
• |
5% to 95% non-condensing |
MTBF |
• |
100,000 hours minimum at full load |
|
|
at +25 °C ambient |
EMC & Safety |
|
|
EMI Requirement |
• |
Meets the conducted limits of |
|
|
EN 55011 (CISPR11) Level B |
Safety Requirements |
• |
Approved to: |
|
|
(Not for patient contact) |
|
|
a) UL2601 |
|
|
b) CSA C22.2 No.601.1-M90 per CUL |
|
|
c) IEC 601-1/EN60601-1 (per TUV) |
• |
|
PH: 508 |
429.9883 |
• |
||
|
||||||
|
||||||
|
|
|
|
|
||
|
|
|
|
FAX: 800 |
226.2100 |
|
|
www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
|
Holliston, MA 01746 USA |
|
||
|
|
|
|