DC/DC Converters
|
|
|
|
|
|
15 Watts |
|
|
|
XPiQ inc. |
|
JTA15 Series |
|
|
|
Intelligent Design Quality Product |
|
|
|
|
|
||
|
|
|
|
|
|
|
• |
Small Size 1.60” x 2.00” x 0.45” |
|
||
|
|
|
|
||
|
|
|
|
• |
|
|
|
|
PRELIMINARY |
|
|
|
|
|
Ultra Wide 4:1 Input |
|
|
|
|
|
|
• |
|
|
|
|
Full Power to +71 °C |
|
|
|
|
|
|
• |
|
|
|
|
|
2003 |
|
|
|
|
Industry Standard Pin Out |
|
|
|
|
|
Q3 |
• |
|
|
|
|
Single & Dual Outputs |
|
|
|
|
|
|
• |
|
|
|
|
Overvoltage & Overcurrent Protection |
|
|
|
|
|
|
• |
|
|
|
|
UL Safety Approvals |
|
|
|
|
|
|
|
|
Specification
Input
Input Voltage |
• |
9-36 VDC |
|
|
18-75 VDC |
Input Current |
• |
2.2 A max at 9 VDC input, 15 W output |
Remote ON/OFF |
• |
ON = Logic High or Open, |
|
|
OFF = Logic Low or shorted to -Vin |
Output |
|
|
Output Voltage |
• |
See Table |
Output Power |
• |
15 Watts |
Output Voltage |
• |
±10% |
Adjustment |
|
|
Minimum Load |
• |
0 minimum load required |
Line Regulation |
• |
±1% maximum |
Load Regulation |
• |
±1% maximum for single output |
|
|
±2% maximum for dual output |
Setpoint Accuracy |
• |
±2% |
Ripple & Noise |
• |
50 mV pk-pk for single output |
|
|
75 mV pk-pk for dual output |
Transient Response |
• |
4% max deviation, |
|
|
recovering to 1% of final value in less |
|
|
than 500 µs after a 25% load change |
Temperature |
• |
±0.02%/°C |
Coefficient |
|
|
Overvoltage |
• |
See table |
Protection |
|
|
Overcurrent |
• |
Continuous with auto recovery |
Protection |
|
|
General
Efficiency |
• |
See table |
MTBF |
• 1,000,000 hrs minimum per |
|
|
|
MIL-HDBK-217F |
Isolation Voltage |
• 1500 VDC Input to Output |
|
Package Style |
• Copper case with non-conductive base |
|
Size |
• 2.00” x 1.60” x 0.45” |
|
Weight |
• |
50 grams approx |
Environmental
Operating |
• |
-25 °C to +100 °C derate from 100% |
Temperature |
|
load at +71 °C to 0% load at +100 °C |
Cooling |
• |
Convection cooled |
Storage |
• |
-55 °C to +105 °C |
Temperature |
|
|
Humidity |
• |
5-95% RH non-condensing |
EMC & Safety
Safety Approvals |
• |
UL/cUL 1950 |
EMI/EMC |
• |
EN55022 Class B conducted |
* Preliminary datasheet - see website for current specs
• |
|
PH: 508 |
429.9883 |
• |
||
|
||||||
|
||||||
|
|
|
|
FAX: 800 |
226.2100 |
|
|
www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
|
Holliston, MA 01746 USA |
|
||
|
|
|
|