AC/DC Open Frame
|
|
|
|
|
|
130 Watts |
|
|
XPiQ inc. |
||
JPP130 Series |
|
|
Intelligent Design Quality Product |
||
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
High Power Density |
|
|
|
• |
|
||
|
|
• |
|
||
|
|
|
|
|
|
|
|
|
|
Small Footprint |
|
|
|
|
|
• |
|
|
|
|
|
Up to Five DC Outputs |
|
|
|
|
|
• |
|
|
|
|
|
Wide Adjustment on 2 Outputs |
|
|
|
|
|
• |
|
|
|
|
|
Short Circuit Protection |
|
|
|
|
|
• |
|
|
|
|
|
Power Fail Detect Signal |
|
|
|
|
|
• |
|
|
|
|
|
Active PFC - Meets EN61000-3-2, -3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Specification
Input
AC Input Voltage |
• 90-264 VAC (120-370 VDC) |
||
Input Frequency |
• |
47-63 Hz |
|
Power Factor |
• |
0.98 typical |
|
Inrush Current |
• |
35 A at 115 VAC, 70 A at 230 VAC |
|
Input Current |
• 2.1 A max at 115 |
VAC, |
|
|
|
1.1 A max at 230 |
VAC |
Output
Output Voltage |
• |
See Table |
Output Voltage |
• User adjustable, See Note 3 |
|
Adjustment |
|
|
Output Power |
• |
130 Watts |
Minimum Load |
• 0.8 A for V1 output to regulate V5 |
|
Line Regulation |
• |
±0.5% max |
Total Regulation |
• ±3% for V2, ±2% for all other outputs |
|
Ripple & Noise |
• 65 mV for V1, 1% peak-peak on all |
|
|
|
other outputs |
Transient Response |
• 4% max deviation, 500 µs recovery |
|
|
|
time for a 25% load change |
Temperature |
• |
0.04%/°C |
Coefficient |
|
|
Hold Up Time |
• |
>15 ms min |
Remote Sense |
• On 3.3 V output only, compensates |
|
|
|
for up to 0.5 V drop |
Overvoltage |
• On V1 & V5 only |
|
Protection |
|
112% to 132% of nominal |
General
Efficiency |
• |
75% typical |
Power Density |
• |
7.2 W/in3 |
MTBF |
• |
200,000 hrs min |
Isolation Voltage |
• 3000 VAC Input to Output |
|
|
|
1500 VAC Input to Ground |
|
|
500 VAC Output to Ground |
Signals |
• PFD = TTL low gives warning of |
|
|
|
at least 10 ms before V1 output drops |
|
|
below 95% of nominal. This signal also |
|
|
provides a minimum of 100 ms delay |
|
|
after V1 is within regulation. |
Size |
• 3.0” x 5.0” x 1.2” |
|
Weight |
• 320 g (0.71 lbs) approx. |
Environmental
Operating |
• -10 °C to +60° C with derating |
Temperature |
Derate linearly from 100% load at |
|
+40 °C to 50% load at +60 °C |
Cooling |
• 10 CFM from two 40mm diameter |
|
fans required. |
Humidity |
• 5 to 95% RH, non-condensing |
Storage |
• -40 °C to +85 °C |
Temperature |
|
EMC & Safety
Safety Approvals |
• UL60950, CSA C22.2 No 60950, |
|
EN60950, CE Mark LVD |
|
Overcurrent |
• On V1 and V5 only. |
EMC |
• Meets EN61000-3-2, -3 |
|
|
|
Protection |
Re-cycle input to reset |
|
|
||
|
|
EN61000-4-2, -3, -4, -5, -6, -8, -11 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
EN55022 FCC Part 15 & |
|
|
|
|
|
|
VCCI Class B conducted, |
|
|
|
|
|
|
Class A radiated |
|
|
|
|
|
|
|
|
|
• |
|
|
PH: 508 429.9883 |
• |
||
|
|
|||||
|
|
|||||
|
|
|
|
FAX: 800 226.2100 |
|
|
|
www.XPiQ.com |
|
Email: sales@xpiq.com |
|
|
|
|
|
Holliston, MA 01746 USA |
|
|
||
|
|
|
|