XPiQ inc PU30-30SL, PU30-31SL, PU30-32SL, PU30-33SL, PU30-10SL Datasheet

...
0 (0)
XPiQ inc PU30-30SL, PU30-31SL, PU30-32SL, PU30-33SL, PU30-10SL Datasheet

055-072 2/5/02 9:46 am Page 7

 

 

 

Switching Power Supply

 

 

 

 

 

 

XPiQ inc.

 

 

30 Watts

 

 

 

PU30 Series

 

Intelligent Design Quality Product

 

 

 

 

 

 

 

 

 

Built-in EMI Filter

 

 

 

 

 

 

 

 

 

 

100% Burn-in

 

 

 

 

 

 

 

 

Input Surge Current Protection

 

 

 

 

 

 

 

 

Small Size, 2.76” x 5.12” x 1.20”

 

 

 

 

 

 

 

 

Universal Input Voltage (85-264 VAC)

 

 

 

 

 

 

 

 

Overvoltage Protection

 

 

 

 

 

 

 

 

Overcurrent Protection

 

 

 

 

 

 

 

 

 

 

Specification

All specifications typical at nominal line, full load and 25°C

Input

Input Voltage

85 to 264

VAC

Input Frequency

47 to 440

Hz

Input Current

0.8A

(rms for 115 VAC

 

 

0.5A

(rms) for 230 VAC

DC Input Voltage

115-280 VDC

Output

Output Voltage:

See Rating Charts

Output Current

See Rating Charts

Output Power Range

0 to 30 Watts

Ripple and Noise

1% peak to peak max.

Overvoltage

Provided on output #1 only;

Protection:

 

set at 112-132% of its nominal

 

 

output voltage

Overcurrent

All outputs protected to short

Protection:

 

circuit conditions

Temperature

All outputs ±0.04%/°C

coefficient:

 

maximum

General

Efficiency

65% minimum at 30 watt output

Hold-up time

12 msec minimum

Line Regulation

±0.5% maximum at full load

Inrush Current

15A at 115

VAC or

 

 

30A at 240

VAC at 25°C cold start

Withstand Voltage

3000

VAC from input to output

 

 

1500

VAC from input to ground

Insulation Resistance

10 Mohm minimum from

 

 

output to ground

Environmental

Operating

0°C to +70°C*

Temperature

 

 

Storage

-40°C to +85°C

Temperature

 

 

MTBF

100,000 hours minimum at full load

 

 

at 25°C ambient

EMI Requirement

Meets the conducted limits of

 

 

a) FCC 20780 Level B

 

 

b) CISPR 22 (EN 55022) Level B

Safety Requirements

Approved to:

 

 

a) UL 1950

 

 

b) CSA C22.2 No.234

 

 

c) TUV per EN60950 (IEC 950)

* Derate linearly from 100% load at 50°C to 50% load at 70°C

PH: 508

429.9883

 

 

 

FAX: 800

226.2100

 

61 www.XP-iQ.com

Email: sales@xp-iq.com

Holliston, MA 01746 USA