055-072 2/5/02 9:46 am Page 7
|
|
|
Switching Power Supply |
|
|
|
|
|
|
|
XPiQ inc. |
|
|
30 Watts |
|
|
|
PU30 Series |
|
|
Intelligent Design Quality Product |
|
|
|
|
|
|
|
|
|
|
• |
Built-in EMI Filter |
|
|
|
• |
||
|
|
|
|
|
|
|
|
|
100% Burn-in |
|
|
|
|
• |
|
|
|
|
Input Surge Current Protection |
|
|
|
|
• |
|
|
|
|
Small Size, 2.76” x 5.12” x 1.20” |
|
|
|
|
• |
|
|
|
|
Universal Input Voltage (85-264 VAC) |
|
|
|
|
• |
|
|
|
|
Overvoltage Protection |
|
|
|
|
• |
|
|
|
|
Overcurrent Protection |
|
|
|
|
|
|
|
|
|
|
Specification
All specifications typical at nominal line, full load and 25°C
Input
Input Voltage |
• |
85 to 264 |
VAC |
|
Input Frequency |
• |
47 to 440 |
Hz |
|
Input Current |
• |
0.8A |
(rms for 115 VAC |
|
|
|
0.5A |
(rms) for 230 VAC |
|
DC Input Voltage |
• |
115-280 VDC |
Output
Output Voltage: |
• |
See Rating Charts |
Output Current |
• |
See Rating Charts |
Output Power Range |
• |
0 to 30 Watts |
Ripple and Noise |
• |
1% peak to peak max. |
Overvoltage |
• |
Provided on output #1 only; |
Protection: |
|
set at 112-132% of its nominal |
|
|
output voltage |
Overcurrent |
• |
All outputs protected to short |
Protection: |
|
circuit conditions |
Temperature |
• |
All outputs ±0.04%/°C |
coefficient: |
|
maximum |
General
Efficiency |
• |
65% minimum at 30 watt output |
||
Hold-up time |
• |
12 msec minimum |
||
Line Regulation |
• |
±0.5% maximum at full load |
||
Inrush Current |
• |
15A at 115 |
VAC or |
|
|
|
30A at 240 |
VAC at 25°C cold start |
|
Withstand Voltage |
• |
3000 |
VAC from input to output |
|
|
|
1500 |
VAC from input to ground |
|
Insulation Resistance |
• |
10 Mohm minimum from |
||
|
|
output to ground |
Environmental
Operating |
• |
0°C to +70°C* |
Temperature |
|
|
Storage |
• |
-40°C to +85°C |
Temperature |
|
|
MTBF |
• |
100,000 hours minimum at full load |
|
|
at 25°C ambient |
EMI Requirement |
• |
Meets the conducted limits of |
|
|
a) FCC 20780 Level B |
|
|
b) CISPR 22 (EN 55022) Level B |
Safety Requirements |
• |
Approved to: |
|
|
a) UL 1950 |
|
|
b) CSA C22.2 No.234 |
|
|
c) TUV per EN60950 (IEC 950) |
* Derate linearly from 100% load at 50°C to 50% load at 70°C
• |
PH: 508 |
429.9883 |
• |
|
|
||
|
FAX: 800 |
226.2100 |
|
61 www.XP-iQ.com |
Email: sales@xp-iq.com |
||