XPiQ inc KHQ04048S1V2BL, KHQ04048S1V2BH, KHQ04048S1V2AL, KHQ04048S1V2AH, KHQ04048S2V5AH Datasheet

...
0 (0)
XPiQ inc KHQ04048S1V2BL, KHQ04048S1V2BH, KHQ04048S1V2AL, KHQ04048S1V2AH, KHQ04048S2V5AH Datasheet

KHQ040.qxd 6/6/03 4:32 pm Page 1

Quarter Brick DC/DC Converters

40 Amps

XPiQ inc.

KHQ040 Series

Intelligent Design Quality Product

 

 

 

 

 

Low Voltage Outputs to 1.2 V

 

 

 

 

40 A Output High Power Density

 

 

 

 

High Efficiency - Up to 89%

 

 

 

 

International Safety Approvals

 

 

 

 

Low Profile 0.417”

 

 

 

Specification

Input

Input Voltage Range

36-75 VDC

Input Current

1.0 A - 3.1 A, See Table

Input Reflected Ripple •

100 mA pk-pk

No Load Input Current •

100 mA at 48 VDC in

Remote On/Off

Shorted to -Vin (Logic Low) = ON

 

 

Open (Logic high) = OFF

 

 

Positive logic is available (see note 3)

Input Reverse Voltage •

External components required

Protection

 

 

Input Transient

Capable of withstanding 110 V

 

 

for 100 mS

Undervoltage lockout

Above 32 to 34 VDC = ON

 

 

Below 30 to 32.2 VDC = OFF

Short Circuit

Protected to short circuit conditions,

Protection

 

hiccup mode

Overtemperature

Shutdown at 125°C auto restart

Protection

 

 

General

Efficiency

• 89% for 3.3 V out, See Table

Isolation

• 1500 V DC Input to Output

Size

• 2.280” x 1.450” x 0.417”

 

(without baseplate)

Package Style

• Open frame, baseplate option

Weight

• 35 g for open frame

MTBF

• 2,000,000 hours demonstrated

Output

Output Voltage

• 1.2 VDC to 3.3 VDC

Voltage Adjustment

±10%

Minimum Load

• No minimum load required

Line Regulation

• ±10mV or 0.5% whichever is greater

Load Regulation

• ±10mV or 0.5% whichever is greater

Setpoint Accuracy

±50 mV

Ripple & Noise

• 100 mV pk-pk maximum

Transient Response

• 200mV max deviation, 100 µs recovery

 

 

time for a 25% load change

Temperature

0.01%/°C

Coefficient

 

 

Remote Sense

• Compensates for up to 10% of

 

 

Vout drop

Overvoltage

• 120%-130%, recycle input to reset

Protection

 

 

Overcurrent

110-135% auto restart

Protection

 

 

Environmental

Operating

• -40° C to +85 °C ambient

Temperature

 

see derating chart

(with 300 LFM)

 

Full power to 40°C

Storage Temperature

-55°C to +125°C

Humidity

5-95% RH non-condensing

EMC & Safety

Safety Approvals

• UL 60950, IEC 60950,

 

CSA 60950 per cUL,

 

CE Marked for LVD

EMI/EMC

• FCC level B Part 15 with

 

external filtering

Warranty

• 1 Year

 

PH: 508

429.9883

 

 

 

 

 

 

FAX: 800

226.2100

 

 

www.XPiQ.com

 

 

Email: sales@xpiq.com

 

 

 

 

Holliston, MA 01746 USA

 

 

 

 

 

Loading...