JPS250Q.qxd 25/6/03 12:26 pm Page 1
AC/DC U-Channel
250 Watts |
|
|
XPiQ inc. |
|
JPS250 Quad Output Series |
|
Intelligent Design Quality Product |
||
|
|
|||
|
|
|
|
|
• |
|
Active PFC - Meets EN61000-3-2, -3 |
||
|
|
|
|
• |
|
|
|
200 W with Convection Cooling |
|
|
|
|
|
• |
|
|
|
Meets 1U, Low Profile Requirements |
|
|
|
|
|
• |
|
|
|
Zero Voltage Switching Technology |
|
|
|
|
|
2003 |
|
|
PRELIMINARY• |
||
|
|
|
Q3 |
|
Remote On/Off / Remote Sense
•
Optional Current Share
Specification
Input
AC Input Voltage |
• |
85-264 VAC |
Input Frequency |
• |
47-63 Hz |
DC Input Voltage |
• |
170-370 VDC |
Inrush Current |
• 30 A max at 115 VAC |
|
|
|
60 A max at 230 VAC |
Input Current |
• 4 A max at 115 VAC |
|
|
|
2 A max at 230 VAC |
Remote On/Off |
• Off = Logic High, or +5 V |
|
|
|
On = Logic Low, or short circuit, |
|
|
or open |
Power Factor |
• 0.98 for 115 VAC, 0.90 for 230 VAC |
Output
Output Voltage |
• |
5-48 VDC |
Output Voltage |
• On output #1 only ±10% |
|
Adjustment |
|
|
Output Power |
• |
250 Watts |
Minimum Load |
• 2 A required on V1 |
|
Line Regulation |
• ±0.5% from low line to high line |
|
Load Regulation |
• ±1% for V1 & V2, ±5% for V3 & V4 |
|
Cross Regulation |
• |
15% maximum |
Set Point Accuracy |
• |
±1% |
Ripple & Noise |
• ±1% peak to peak maximum |
|
Transient Response |
• 4% max deviation, 500 µs recovery |
|
|
|
time for a 25% load change |
Overcurrent |
• 120% - 150% with auto recovery |
Protection |
|
Overtemperature |
• Standard |
Protection |
|
Current Share |
• Single wire current sharing on |
|
V1 & V2 (optional) |
Fan Output |
• 12 V at 100 mA |
General
Efficiency (typical) |
• >80%, nominal line full load |
||
Power Density |
• |
4.9 W/in3 |
|
MTBF |
• 255,000 hrs min to MIL-HDBK-217F |
||
Withstand Voltage |
• 3000 |
VAC Input to Output |
|
|
|
1500 |
VAC Input to Ground |
|
|
500 VAC Output to Ground |
|
Size |
• 8.0” x 4.2” x 1.5” |
||
Weight |
• |
770 grams approx |
|
Signals |
• AC OK = Logic Hi, DC OK = Logic Hi |
Environmental
Operating |
• 0 °C to +70 °C See Derating Chart |
||
Temperature |
|
Full power to 50 °C |
|
Cooling |
• |
250 |
W with 18 CFM airflow |
|
|
200 |
W Convection Cooling |
Storage Temperature |
• |
-20 °C to +85 °C |
Safety and EMC
Temperature |
• ±0.05%/°C |
Coefficient |
|
Hold Up Time |
• 20 ms minimum at low line |
Remote Sense |
• V1 & V2 compensates for up to |
|
0.5 V drop |
Overvoltage |
• 115% to 140%, recycle input to reset |
Protection |
|
Safety Approvals |
• UL60950, CSA C22.2 No 234, |
|
EN60950, CE Mark LVD |
EMI/EMC |
• EN61000-3-2, -3, |
|
EN55022 Class B and FCC 20780 |
|
Level B conducted |
Immunity & Surge |
• EN50082-2 (EN61000-4-2,-3, -4, -5) |
|
Performance criteria A |
* Preliminary datasheet - see website for current specs
• |
|
PH: 508 |
429.9883 |
• |
|
|
|||||
|
|||||
|
|
|
|
||
|
|
|
FAX: 800 |
226.2100 |
|
29 www.XPiQ.com |
|
|