XPiQ inc KHQ03048S1V5AL, KHQ03048S1V5AH, KHQ03048S1V2BL, KHQ03048S1V2AH, KHQ03048S3V3BH Datasheet

...
0 (0)
XPiQ inc KHQ03048S1V5AL, KHQ03048S1V5AH, KHQ03048S1V2BL, KHQ03048S1V2AH, KHQ03048S3V3BH Datasheet

KHQ030.qxd 6/6/03 4:31 pm Page 1

Quarter Brick DC/DC Converters

30 Amps

XPiQ inc.

KHQ030 Series

Intelligent Design Quality Product

 

 

 

 

Low Voltage Outputs

 

 

 

 

High Power Density

 

 

 

 

Efficiency 91% for 3.3V/30 A

 

 

 

 

ETS 300-321-2 Isolation

 

 

 

 

International Safety Approvals

 

 

 

 

Fixed Switching Frequency

 

 

 

 

Low Profile

 

 

 

Specification

Input

Input Voltage Range

36-75 VDC

Input Current

See Table

Input Reflected

20 mA pk-pk

Ripple Current

 

 

Remote ON/OFF

Shorted to -Vin (Logic Low) = ON

 

 

Open (Logic high) = OFF

 

 

Negative logic is standard,

 

 

Positive logic is available (See Note 3)

Input Reverse Voltage •

External components required

Protection

 

(See Note 4)

Input Transient

100 V for 100 ms

Undervoltage

Above 32 to 34 VDC = ON

Lockout

 

Below 30 to 32.2 VDC = OFF

Output

Output Voltage

• 1.2 VDC to 3.3 VDC

Output Voltage

±10%

Adjustment

 

 

Minimum Load

• No minimum load required

Line Regulation

• ±0.5% (36-75 VDC; full load)

Load Regulation

±0.5%

Output Voltage

±50 mV

Accuracy

 

 

Ripple & Noise

• 100 mV pk-pk, 20 MHz bandwidth

Transient Response

• 3% max deviation, 100 µs recovery

 

 

time for a 25% step load change

Temperature

0.01%/°C

Coefficent

 

 

Remote Sense

• Compensates for drop of up to 10%

 

 

of output

Overvoltage

• 120%-130%, recycle input to reset

Protection

 

 

Overcurrent

• 110-135% auto restart

Protection

 

Short Circuit

• Protected from short circuit

Protection

conditions, hiccup mode

Overtemperature

• Shutdown at 110 °C (measured

Protection

on board), auto restart

General

Efficiency

See Table

Isolation

• 1500 VDC Input to Output

Size

• 2.280” x 1.450” x 0.417”

 

 

(0.5” with baseplate)

Switching Frequency

330-350 kHz

Weight

• 35 g for open frame version

 

 

65 g for baseplate version

MTBF

• 2,000,000 hours calculated to Bellcore

Environmental

Operating

• -40 ° C to +85 °C ambient with

Temperature

derating, full power to +50 °C with

 

200 LFM

Storage Temperature

• -55 °C to +125 °C

Cooling

• Convection cooled or forced air

 

(See Derating Curve)

Humidity

• 5-95% RH non-condensing

EMC & Safety

Safety Approvals

UL 60950, IEC 60950,

 

 

CSA 60950 per cUL,

 

 

CE Marked for LVD

EMI/EMC

FCC level B Part 15 with

 

 

external filtering (See Note)

 

PH: 508

429.9883

 

 

 

 

 

 

 

 

 

 

 

FAX: 800

226.2100

 

 

www.XPiQ.com

 

 

Email: sales@xpiq.com

 

 

 

 

Holliston, MA 01746 USA

 

 

 

 

 

Loading...