tekmar 530 Quick Start [en, es, fr]

530_Q
tekmarNet®2 Thermostat 530
Quick Setup Guide
1. Location
Behind
Door
Exterior
Wall
2. Remove Mounting Base
Zoning
02/14
Replaces: 12/13
Interior
Wall
5 feet
1.5 m
3. Install Mounting Base
Plate 007
Thermostat
Base
Switch
Box
A Watts Water Technologies Company
1
Thermostat
Base
OR
Wall
© 2014 530_Q - 02/14
4. Wiring
G Y R
D
X
Cooling Equipment
tN2 House Control, Manager,
Fan
Cooling
1 Stage Cooling
1 Stage
Fan
Module or Wiring Center
5
G
4
Y
3
Rc
For instructions see brochure Use at least 65°C conductors
tN21tN2
2
tN2 tN2
tNt 530
One Stage Heat / One Stage Cool / One Fan
Relays: 24V (ac) 2A
ON
Setback
Off
Switch Settings:
1234
12 34
Switch Setting Location
1023- 04
Scene
Off
Lock
Unlock
530
Not used
Not used
Mmm YYYY
Lot # 12345
Meets Class B:
Canadian ICES
FCC Part 15
5. Switch Settings
Switch
A Watts Water Technologies Company
1
2
3
4
Position
ON
Action
SETBACK Allow thermostat to respond to
available schedule. Requires Timer 033.
OFF OFF No setback schedule response.
ON
SCENE Allow thermostat to respond to scenes. Requires User Switch 479.
OFF OFF No scene response.
ON
OFF
LOCK Locked to ‘User’ access level. Set to Lock when installation completed.
UNLOCK Unlock to access all settings. Set to Unlock during installation.
ON Not used
OFF Not used
2
© 2014 530_Q - 02/14
6. Close Thermostat
pivot
tab
7. User Interface
Mode button
Auto, Heat, Cool, Off
Fan button
Switch between Auto or On
8. Critical Settings
The following settings are essential to the successful operation of the system.
Important
Access level to Installer. Return to Lock setting once installation has been completed.
A Watts Water Technologies Company
Note: Set switch setting #3 and tekmarNet® system control to Unlock to change
Press
+
Both
• Press and hold down both the and buttons for 2 seconds to change from one step to the next.
• Release both buttons once the step has been reached.
• Press the or the button to change the setting, if available.
• Press and hold down both the and buttons for 2 seconds to go to the next step, OR
• After 10 seconds of no button activity, the display goes back to normal operation.
3
© 2014 530_Q - 02/14
8. Critical Settings (Continued)
H1
ADJUST
Display Range Access Description
°F or °C Default =
°F
Set To:
Installer User
TEMPERATURE UNITS
Press the or the button to change from °F to °C and vice versa.
ADJUST
SUPPLY
0, 1, 2, 3 Default = 1
Installer
Select how the fan should operate together with heating and cooling. 0 = Manual operation only 1 = Operate fan with cooling only 2 = Operate fan with heating and cooling
FAN MODE
Set To:
3 = Operate fan with heating only
Hyd (Hydronic)
or Oth (Other)
Default = Hydronic
Set To:
On or Off Default =
On
Installer
HEATING TERMINAL TYPE
Select if the heating for this zone is hydronic or non-hydronic (other).
Available when:
• A reset control is present on the tekmarNet® system.
HEAT SUPPLY PUMP
During heating, select whether or not the system supply pump should turn on or be off to allow a zone
Installer
H1
Set To:
group pump per manifold. Available when:
• A reset control is present on the tekmarNet® system AND Heating terminal type is set to Hydronic.
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual (530_D) included with compatible
tekmarNet® controls or download the brochure from www.tekmarcontrols.com
Product design, software and literature are Copyright ©2014 by tekmar Control Systems Ltd.,
All specifications are subject to change without notice
A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650
4 530_Q - 02/14.
Web Site
: www.tekmarControls.com