Tekmar 518 User Manual

Page 1
518_D
Thermostat 518
Installation & Operation Manual
Introduction
The Thermostat 518 accurately controls the room temperature for a hydronic heating zone using Pulse Width Modulation (PWM) technology. Simple up and down buttons and a display with large type make this thermostat easy to read and use. The 518 automatically detects a single auxiliary sensor to measure either outdoor, floor or remote room temperature. This easy to install thermostat is a direct replacement for tekmar Thermostats 507 and 508.
03/13
Zoning
Replaces: New
Energy Saving Features
Auto Heating Cycle
Additional Features
Radiant Floor Heating
• Pulse Width Modulation
• Auxiliary Sensor Input
• Outdoor & Floor Temperature
• Display
Backlight
• Freeze Protection
A Watts Water Technologies Company
1 of 12
518_D - 03/13
Page 2
Table of Contents
------------------------------------------------------
Getting Started ...............................2
Installation ...........................................2
Preparation .....................................2
Removing The Thermostat Base ....3
Mounting The Thermostat...............4
Thermostat Wiring ..........................5
Testing the Thermostat Wiring ........6
User Interface ......................................7
Home Screen ..................................7
Symbols Description .......................7
Sequence of Operation ........................8
Heating Operation ...........................8
Programmable Settings .......................9
Troubleshooting .................................10
Error Messages ............................10
Frequently Asked Questions ........11
Technical Data .............................. 11
Limited Warranty and Product
Return Procedure .........................12
Getting Started
Congratulations on the purchase of your new tekmar® thermostat. This manual will step through the complete installation, programming and sequence
of operation for this control. At the back, there are tips for control and system troubleshooting.
Installation
Caution
Improper installation and operation of this control could result in damage to the equipment and possibly even personal injury or death. It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards. This electronic control is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit.
Preparation
Tools Required
tekmar or jeweller screwdriver
• Phillips head screwdriver
A Watts Water Technologies Company
------------------------------------------------------
Wire Stripper
2 of 12
© 2013 518_D - 03/13
Page 3
-------------------------------------------------
Materials Required
--------------------------------------------------
18 AWG LVT Solid Wire
--------------------------------------------------
(Low Voltage Connections)
Installation Location
Choose the placement of the thermostats early in the construction process to enable proper wiring during rough-in.
Consider the following:
Interior Wall.
• Keep dry. Avoid potential leakage onto the control.
• Relative Humidity less than 90%. Non-condensing environment.
• No exposure to extreme temperatures beyond 32-122°F (0-50°C).
• No draft, direct sun, or other cause for inaccurate temperature readings.
• Away from equipment, appliances, or other sources of electrical interference.
• Easy access for wiring, viewing, and adjusting the display screen.
• Approximately 5 feet (1.5 m) off the finished floor.
• The maximum length of wire is 500 feet (150 m).
• Strip wire to 3/8” (10 mm) for all terminal connections.
• Use standard 4 conductor, 18 AWG wire.
-------------------------------------------------
Removing The Thermostat Base
To remove the thermostat base:
Locate the tab on the bottom of the
• thermostat.
Push the tab with either your thumb or with
• a screwdriver.
Lift the thermostat front away from the
• thermostat’s base.
A Watts Water Technologies Company
3 of 12
© 2013 518_D - 03/13
Page 4
Mounting The Thermostat
Stud
3 1/4
(83 mm)
Gang Box
Thermostat
Front
Adapter Plate 012
Thermostat
Base
If a single gang box is used:
Adapter Plate 012 is required (sold separately).
• Feed the wiring through the hole in the adaptor plate and the thermostat base.
• Fasten the adaptor plate to the gang box.
• Fasten the base of the thermostat to the adaptor plate.
• Terminate wiring to the wiring strip.
• Push the thermostat front onto the thermostat base.
Thermostat
Thermostat
Front
Base
Wall
If mounting directly to the wall:
Drill holes and install the wall anchors.
• Feed the wiring through the large hole in the thermostat base.
• Fasten the thermostat base to the wall using the wood screws to the wall
• anchors.
Terminate wiring to the wiring strip.
• Push the thermostat front onto the thermostat base.
A Watts Water Technologies Company
4 of 12
© 2013 518_D - 03/13
Page 5
Thermostat Wiring
----------------------------------------------------------
---------------------------------------------
-----------------------------------------------------------
Zone Valve
----------------------------------------------------------
Zone Valve
RC
24 V (ac)
Tra ns fo rm er
009
LN
Wiring Center 315 or 316
R
tN4 C W
Wiring Center
315 or 316
Install field jumper wire R to Rh
No Power
C
R Rh W1 S1 Com
C
R Rh W1 S1 Com
No Power
518
518
---------------------------------------------
Optional Slab Sensor 079
Install field jumper wire R to Rh
518
518
518
C
R Rh W1 S1 Com
C
R Rh W1 S1 Com
C
R Rh W1 S1 Com
No Power
No Power
No Power
Optional Slab Sensor 079
Relay 003
-----------------------------------------------------------
Relay 003
2
3
1
4
8
5 6
7
R
C
LNG
115 V (ac)
A Watts Water Technologies Company
Tran sfo rm er
009
Install field jumper wire R to Rh
518
518
C
R Rh W1 S1 Com
C
R Rh W1 S1 Com
5 of 12
No Power
No Power
Optional Slab Sensor 079
© 2013 518_D - 03/13
Page 6
-----------------------------------------------------
---------------------------------------------------
----------------------------------
Thermostat Wiring
Switching Relay
-----------------------------------------------------
Optional Slab Sensor 079
No Power
C
R Rh W1 S1 Com
C
R Rh W1 S1 Com
No Power
24 V
Com
Class 2
Transformer
RW
RW
Zone 1 Zone 2 Zone 3
Switching Relay
Zone 1 Zone 2 Zone 3 HNXX HNHN NH
RW
518
518
LN
Pump
Testing the Thermostat Wiring
Testing the Power
If the thermostat display turns on, this indicates that the thermostat is operating correctly and there are no electrical issues. In the event that the display is permanently off:
1. Remove the thermostat front.
2. Use an electrical meter to measure voltage between the R and C wiring terminals. For AC power supplies the voltage should measure between 10 to 30 V (ac). For DC power supplies the voltage should measure between 10 to 30 V (dc).
3. If the voltage on the R and C wire terminations is continuous and the thermostat display is not on, the thermostat may have a fault. Contact your tekmar sales representative for assistance.
If the thermostat display intially powers on but later shuts off intermittantly, there may be a short circuit from the W wire to ground, or the power supply is too small to
power the load.
---------------------------------------------------
Testing the Heat Zone Output Wiring
----------------------------------
1. Touch the button and set the heating temperature above the current room temperature. Make sure the display does not flash “Max” if using a floor sensor.
2. When the “Heat On” symbol appears on the display, use an electrical meter to check for voltage on the W and C wires connected to the zone valve, wiring center, relay or switching relay. The electrical meter should read 10 to 30 V (ac) or (dc).
3. If the W and C wire have voltage, check the zone valve, wiring center, relay or pump to determine if the heat device is operating correctly.
A Watts Water Technologies Company
6 of 12
© 2013 518_D - 03/13
Page 7
User Interface
Home Screen
Symbols Description
HEAT ON
Heat is turned on.
MODE OFF
The heating system is off.
WARNING SYMBOL
Indicates an error is present.
A Watts Water Technologies Company
7 of 12
MIN
The floor is at or below the floor minimum temperature.
MAX
The floor has reached the floor maximum temperature.
© 2013 518_D - 03/13
Page 8
Sequence of Operation
------------------------------------------------
----------------------------------------------
-------------------------------------------
Heating Operation
To change the heat temperature setting, push the or button to select a preferred temperature setting. The Heat On symbol is shown on the display when the thermostat is heating. The heat can cycle on and off within +/- 1.5°F (1°C) of the temperature setting.
The floor and air heating can be shut off by holding the button until Set Room is Off. To resume heating when the Mode is Off, press the
setting, then press the button to select Mode Heat. The thermostat will resume heating at the last previously set temperature.
button to navigate to the Mode
Air Temperature Only
If there is only an air temperature sensor (no floor sensor), the thermostat operates to control your desired air temperature.
Floor Temperature Only
If the air sensor has been disabled, the thermostat will only maintain floor temperature and ignore air temperature. This operation is recommended for areas such as bathrooms to ensure that tile floors are warm to the touch.
Floor and Air Temperature
If the air sensor is turned on and a floor sensor is connected, the thermostat will maintain the desired air temperature as well as a minimum floor temperature.
This operation is recommended for areas with large windows that allow the sun to shine into a room and keep it warm without the need for heat. This can allow the floors to cool off during the afternoon. When the sun goes down, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room.
This operation is also recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings.
90°F (32°C) Feels hot to the touch
------------------------------------------------
----------------------------------------------
-------------------------------------------
Suggested maximum for all floor types other than wood.
80 to 85°F (26 to 30°C) Feels warm to the touch
70°F (21°C) Feels cool to the touch
40 to 45°F (5 to 7°C) Feels cold to the touch
A Watts Water Technologies Company
Bathrooms and kitchens. Suggested maximum for wood floors.
Rooms with large windows preventing under heating in the evening.
Freeze protection for garages.
8 of 12
© 2013 518_D - 03/13
Page 9
Programmable Settings
Setting Display
User settings. Press the and buttons together for 3 seconds to enter and advance to the next setting.
MODE
Select heat or off. Range: HEAT, OFF
Default: HEAT
UNITS
Select the temperature units. Range: °F or °C
Default: °F
LIGHT
Select when the display back light should operate. Auto operates the backlight for 30 seconds after a keystroke.
Range: OFF, AUTO, ON
Default: AUTO
SET FLOOR
Set the floor minimum temperature. Available when an
F
auxiliary floor sensor is connected and the built-in room sensor is on.
Range: OFF, 40 to 122°F (4.5 to 50.0°C)
Default: 72°F (22.0°C)
TYPE
Device Type number. Hold the
button to view the
software version.
ESCAPE
Release the
and buttons to return to the home screen.
Installer settings. Press the and buttons together for 5 more seconds. AUXILIARY SENSOR
Select the type of auxiliary sensor. Available when an auxiliary sensor is automatically detected.
Range: NONE = no auxiliary sensor, ROOM = Indoor Sensor, FLOR = Slab Sensor, OUT = Outdoor Sensor
Default: OFF
ROOM SENSOR
Select if the built-in room temperature sensor is on or off. The built-in room sensor can only be disabled when an auxiliary room or slab sensor is connected.
Range: ON or OFF
Room
Default: ON
SET FLOOR MAXIMUM
Set the floor maximum temperature in order to protect the floor covering. Suggested settings: Tile = 90°F (32°C),
MAX
F
Wood Floor = 85°F (29°C) Range: 40 to 122°F (4.5 to 50.0°C), OFF
Default: 85°F (29.5°C)
ESCAPE
Release the
A Watts Water Technologies Company
and buttons to return to the home screen.
9 of 12
© 2013 518_D - 03/13
Page 10
Troubleshooting
Error Messages
Error Message Description
SETUP MENU SAVE ERROR
The thermostat failed to read the Programmable Settings from memory and has reloaded the factory default settings. The thermostat stops normal operation until all Programmable Settings are checked except to provide freeze protection.
ROOM SENSOR OPEN CIRCUIT ERROR
The built-in air temperature sensor has an open circuit fault. Do not confuse this error with the auxiliary room sensor short circuit error.
Room
Room
This error cannot be field repaired. Contact your wholesaler or tekmar sales representative for details on repair procedures.
ROOM SENSOR SHORT CIRCUIT ERROR
The built-in air temperature sensor has a short circuit fault. Do not confuse this error with the auxiliary room sensor short circuit error.
This error cannot be field repaired. Contact your wholesaler or tekmar sales representative for details on repair procedures.
AUXILIARY SENSOR OPEN CIRCUIT ERROR
The auxiliary sensor has an open circuit. Check for loose or damaged wires. Locate and repair the problem as described in the sensor Installation & Operation Manual (070_D, 079_D). The error clears once the auxiliary sensor fault is corrected. If the auxiliary sensor was intentionally removed, power the thermostat down and up to clear the error.
AUXILIARY SENSOR SHORT CIRCUIT ERROR
The auxiliary sensor has a short circuit. Check for damaged wires. Locate and repair the problem as described in the sensor Installation & Operation Manual (070_D, 079_D). The error clears after the auxiliary sensor fault is corrected.
A Watts Water Technologies Company
10 of 12
© 2013 518_D - 03/13
Page 11
Frequently Asked Questions
Symptom Look for... Corrective Action
The power supply transformer
may have limited VA capacity. A
transformer with a larger VA rating is
recommended.
Thermostat must be in Mode Heat in
order to provide heating.
Display powering
on and off.
Thermostat does
not heat.
Measure voltage at
wiring terminals R
and C.
Mode Off
Technical Data
Thermostat 518 One Stage Heat
Literature 518_C, 518_ D, 518 _Q, 518_U Control Microprocessor control. This is not a safety (limit) control Packaged weight 0.53 lb. (240 g) Dimensions 3-11/16” H x 3” W x 15/16” D (94 x 76 x 24 mm) Enclosure White PVC plastic, NEMA Type 1 Approvals Meets Class B: ICES & FCC Part 15 Ambient conditions
Power supply
Relay 30 V (ac/dc) 2 A, Class 2 circuits Sensor – Included None – Optional tekmar type # 070, 072, 073, 076, 077, 079, 084
Indoor use only, 32 to 122°F (0 to 50°C), RH ≤90% non-condensing 10 to 30 V (ac/dc), 50/60 Hz, 1.8 VA standby,
56 VA max fully loaded, Class 2
NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892
A Watts Water Technologies Company
11 of 12
© 2013 518_D - 03/13
Page 12
Limited Warranty and Product Return Procedure
Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt
of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same.
The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass­through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass­through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date.
The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the war­ranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defec­tive Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers.
Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar’s instruc­tions.
THIS WARRANT Y IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IM PLIED, WHICH THE G OVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING , WITHOUT LIMITATION, IMPLIED WAR­RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIP­TION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COM PLIANC E WIT H OR N ON-VIO LATION OF AN Y APPLICABLE ENVIR ONMENTAL, H EALTH OR SAFE TY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIM­ITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materi­als must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.
Product design, software and literature are Copyright ©2013 by tekmar Control Systems Ltd., A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650
All specifications are subject to change without notice
Web Site
: www.tekmarControls.com
12 of 12 518_D - 03/13.