www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

 

Maytag

 

Product Model Number (s):

 

All Maytag Gas Dryers Beginning with the letters:

 

 

MDG

 

 

EXCEPT: MDG75 and MDG55

 

Dimensions (Actual Size)

Width: 27" Height including control panel (0" leg adj): 43 1/4"

Height NOT including control

panel (0" leg adj): 36 1/4" Depth: 28 1/4"

Depth with door open: 50 1/2" Minimum distance from working surface to

cabinets directly above: 17" Maximum depth of cabinet directly above: 14"

Minimum clearance from back wall: 0"

Minimum distance to door in front: 2"

Minimum clearance right and left: 0"

Additional Information

Electrical requirements: 120V, 60Hz, 15 ampere grounded, fused electrical supply is required. An individual branch (or separate circuit serving only this appliance is recommended).

Minimum wire size of 14 gauge (12 preferred), copper wire only.

Exhaust requirements:

-Dryer may be vented out rear, left side or through floor (when venting left or down use Kit 33001881).

-Dryer must be exhausted to the outside.

-Use a minimum of 4" diameter rigid aluminum or rigid galvanized steel duct.

-Keep exhaust as straight and short as possible. Exhaust systems longer than the chart on page 2 will extend drying time, affect machine performance and collect lint.

-Termination hood should have at least 12" of clearance between the bottom of the hood and the ground or other obstructions.

-Back pressure must not exceed 0.92" of water column when measured with a manometer.

See page 2 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2002.

337

14" max.

 

 

Side View

 

 

Closet door

 

 

 

(not to scale)

0"

 

 

 

 

Some models

 

 

 

 

 

 

have 90° corner

 

 

7 1/2"

 

 

 

3 7/8"

 

 

 

at 0"

 

 

 

Leg Adj

 

 

Left

 

 

 

side

28 1/4"

 

 

vent

2" min.

 

Front View

 

(not to scale)

17"

 

36 1/4"

43 1/4"

at 0"

at 0"

Leg Adj.

Leg Adj.

 

0" wall clearance 27"

permissible on both sides

Back of unit

Rear and Floor Venting

(looking out into room)

(not to scale)

 

 

 

 

7 1/2"

 

13 1/2"

Back wall

 

 

 

 

3 1/4"

 

 

 

2 7/8" at 0"

 

3 7/8" at 0"

13 1/2"

Leg Adj.

 

 

 

Leg Adj.

 

 

 

Floor

 

Gas Inlet Pipe

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN • A337B149 • • 032603 • 9570 • 70651