Maytag MDG20PRAWW, MDG20MNAWW, MDE20CSAYW, MDE20PRAYW Installation Guide

0 (0)

INSTALLATION INSTRUCTIONS

Commercial Dryer Gas or Electric

INSTRUCTIONS D’INSTALLATION

Sécheuse à usage commercial À gaz ou électrique

TABLE OF CONTENTS

.

DRYER SAFETY..................................................................................................

2

TOOLS & PARTS ................................................................................................

5

DIMENSIONS/CLEARANCES ..................................................................

6

GAS DRYER INSTALLATION REQUIREMENTS ..............................

7

ELECTRIC DRYER INSTALLATION REQUIREMENTS ..............

10

DRYER VENTING REQUIREMENTS ..................................................

13

GAS SUPPLY CONNECTION .................................................................

15

INSTALLING LEVELING LEGS, COIN SLIDE, AND

 

COIN BOX.........................................................................................................

17

ELECTRIC DRYER ELECTRICAL CONNECTIONS .....................

18

LEVELING ..........................................................................................................

23

COMPLETE INSTALLATION .....................................................................

24

REVERSING DRYER DOOR SWING ...................................................

25

CHANGING TO A 30OR 60-MINUTE TIMING CAM .................

26

MAINTENANCE INSTRUCTIONS .........................................................

27

IF YOU NEED ASSISTANCE ....................................................................

27

ELECTRONIC CONTROL SETUP INSTRUCTIONS ...................

28

WARRANTY.........................................................................................................

33

TABLE DES MATIÈRES

.

SÉCURITÉ DE LA SÉCHEUSE.............................................................

35

OUTILS ET PIÈCES ...................................................................................

38

DIMENSIONS/DISTANCES DE DÉGAGEMENT .......................

39

EXIGENCES D’INSTALLATION POUR LA

 

SÉCHEUSE À GAZ.....................................................................................

40

EXIGENCES D’INSTALLATION POUR

 

LA SÉCHEUSE ÉLECTRIQUE ............................................................

43

EXIGENCES CONCERNANT L’ÉVACUATION

 

DE LA SÉCHEUSE .....................................................................................

45

RACCORDEMENT À LA CANALISATION DE GAZ .....................

47

INSTALLATION DES PIEDS DE NIVELLEMENT,

 

DE LA GLISSIÈRE À MONNAIE ET DE LA CAISSE

 

À MONNAIE ...................................................................................................

49

NIVELLEMENT ...............................................................................................

50

ACHEVER L’INSTALLATION .....................................................................

51

INVERSION DU SENS D’OUVERTURE DE

 

LA PORTE .........................................................................................................

52

INSTALLATION D’UNE CAME DE MINUTAGE

 

DE 30 OU 60 MINUTES ............................................................................

53

INSTRUCTIONS D’ENTRETIEN ............................................................

54

SI VOUS AVEZ BESOIN D’ASSISTANCE ........................................

54

INSTRUCTIONS DE RÉGLAGE DU TABLEAU

 

DE COMMANDE ÉLECTRONIQUE ...................................................

55

GARANTIE.........................................................................................................

61

W10868655A

 

W10868673A – SP

www.maytagcommerciallaundry.com

Maytag MDG20PRAWW, MDG20MNAWW, MDE20CSAYW, MDE20PRAYW Installation Guide

DRYER SAFETY

■■ It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer smells gas. This information should be obtained from your gas supplier.

■■ Post the following warning in a prominent location.

2

DRYER SAFETY

IMPORTANT: When discarding or storing your old clothes dryer, remove the door.

3

DRYER SAFETY

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following:

■■ Read all instructions before using the dryer.

■■ This dryer is intended only for drying clothes and textiles that have been washed in water. Do not use for any other purpose.

■■ WARNING: If you smell gas, do not use the dryer or any electrical equipment nearby. Warn other people to clear the area. Contact the dryer owner immediately.

■■ Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

■■ Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable, or explosive substances as they give off vapors that could ignite or explode.

■■ Do not dry unwashed items in the dryer.

■■ Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

■■ Before the dryer is removed from service or discarded, remove the door to the dryer compartment.

■■ Do not reach into the dryer if the drum is moving.

■■ Do not open door while dryer is in operation. It will stop.

■■ Do not install or store the dryer where it will be exposed to the weather.

■■ Do not tamper with controls.

■■ Clean dryer lint screen before or after each load.

■■ Do not use this dryer without the lint screen in place.

■■ Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Installation Instructions or in published user-repair instructions that you understand and have the skills to carry out.

■■ Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

■■ Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

■■ The final part of a tumble dryer cycle occurs without heat (cool-down cycle) to ensure that the articles are left at a temperature that ensures that the items will not be damaged.

■■ WARNING: Never stop a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated. (Avoids risk of spontaneous combustion).

■■ Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

■■ The interior of the dryer and dryer exhaust vent should be cleaned periodically by qualified service personnel.

■■ See “Electrical Requirements” section for grounding instructions.

SAVE THESE INSTRUCTIONS

4

TOOLS & PARTS

Tools Needed:

8" (203 mm)

8" (203 mm) or 10" (254 mm)

Flat-Blade Screwdriver

Phillips Screwdriver

or 10" (254 mm)

Adjustable Wrench

 

 

Pipe Wrench

that opens to 1" (25 mm)

 

 

Torx®† T-20 Security

1" (25 mm) Hex-Head

5⁄16" (8 mm) Socket Wrench

Pliers (that open to

Screwdriver or Bit

Socket Wrench

 

19/16" [39 mm])

Level

Utility Knife

1/4" (6 mm) Nut Driver

27" (686 mm)

 

 

 

Wood Block

Caulk Gun and Caulk

Vent Clamps

Pipe-Joint Compound

Putty Knife

(for installing new exhaust vent)

 

Suitable for Gas Type

 

Flashlight (optional)

1" (25 mm)

Ruler or Measuring Tape

 

Open-End Wrenches

 

Parts Supplied:

Foot Boots (4)

Leveling Legs (4)

Bezel Kit (PR models only)

Security Cone

5/16" Hex Head –

3-Pin 60-Minute Timing Cam

6-Pin 30-Minute Timing Cam

(PD models only)

18 x 212" Security Bolt

(CS models only)

(CS models only)

 

(PD models only)

 

 

†® TORX and T25 are registered trademarks of Acument Intellectual Properties, LLC.

5

DIMENSIONS/CLEARANCES

Dimensions

Side View Back View

291/4" (743 mm)

26" (660 mm)

81/4" (210 mm)

35"

 

(889 mm)

 

 

31/4"

 

(83 mm)

 

71/2"

1"

(191 mm)

(25 mm)

 

 

27"

 

 

 

 

(686 mm)

 

 

 

 

Electric

 

 

 

 

131/2"

 

 

 

 

(343 mm)

36"

 

41"

 

103/4"

(914 mm)

 

(1042 mm)

11/2"

(273 mm) (electric models)

 

 

 

371/2"

(38 mm)

4" dia

(953 mm)

 

(102 mm)

(gas models)

51/2"

Gas

 

 

 

 

 

 

 

(140 mm)

 

 

 

 

 

131/2"

31/4"

 

 

 

(343 mm)

 

 

 

 

(83 mm)

 

 

Clearances

Front View, Recessed Opening

Side View, Recessed In Closet

 

14" max

 

14" max

 

 

(356 mm)

 

 

 

 

(356 mm)

 

 

 

 

 

 

 

 

 

3"/3"

 

 

 

 

(76 mm) 48"2/48"2

 

15"

 

15"

(310 cm2)

 

(381 mm)

 

(381 mm)

 

 

 

 

 

24"2/24"2

 

 

 

3"/3"

(155 cm2)

 

 

 

(76 mm)

 

0"

 

0"

 

 

(0 mm)

0"

(0 mm)

1"

 

 

 

(25 mm)

 

0"

(0 mm)

 

 

0"

Closet Door to

 

 

 

(0 mm)

 

 

 

(0 mm)

Front of Dryer

 

 

 

 

6

GAS DRYER INSTALLATION REQUIREMENTS

Location Requirements

Your dryer can be installed in a basement, laundry room, or recessed area.

Companion appliance location requirements should also be considered.

IMPORTANT: Do not install or store the dryer where it will be exposed to the weather. Proper installation is your responsibility.

You will need:

■■ A grounded electrical outlet located within 6 ft. (1.8 m) of where the power cord is attached to the back of the dryer. See “Electrical Requirements.”

■■ A level floor with a maximum slope of 1" (25 mm) under entire dryer. Installing the dryer on soft floor surfaces, such as carpets or surfaces with foam backing, is not recommended.

Gas dryer installation clearances

■■ The location must be large enough to allow the dryer door to be fully opened.

■■ Additional spacing should be considered for ease of installation and servicing. The door opens more than 180°.

■■ Additional clearances might be required for wall, door, and floor moldings.

■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

When installing a gas dryer:

IMPORTANT: Observe all governing codes and ordinances.

■■ Check code requirements: Some codes limit or do not permit installation of clothes dryers in garages, closets,

or sleeping quarters. Contact your local building inspector.

■■ Make sure that lower edges of the cabinet, plus the back and bottom sides of the dryer, are free of obstructions to permit adequate clearance of air openings for combustion air. See “Recessed Area and Closet Installation Instructions” below for minimum spacing requirements.

Recessed Area and Closet Installation Instructions

This dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer or in “Dimensions/Clearances.”

The installation spacing is in inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. The unobstructed opening needs to be 1 square inch per 1,000 Btu (252 kcal) of gas burner output. Output on North American gas dryers is typically 22,000 Btu; however, Canadian dryers may have lower output. Louvered doors with equivalent air openings are acceptable.

The dryer must be exhausted outdoors.

No other fuel-burning appliance may be installed in the same closet as the dryer.

48 in.2

(310 cm2) 3"

(76 mm)

Front

 

 

 

Closet

View

 

Closet

 

Door

View

 

door

 

 

 

3" (76 mm)

24 in.2

(155 cm2)

7

GAS DRYER INSTALLATION REQUIREMENTS

Electrical Requirements

Gas Dryer Grounding

IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575 ■■ Do not ground to a gas pipe.

■■ Do not have a fuse in the neutral or ground circuit.

■■ A 120 volt, 60 Hz, AC only, 15or 20-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this dryer be provided.

■■ This dryer is equipped with a power supply cord having a 3-prong grounding plug.

■■ To minimize the possibility of shock, the cord must be plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.

■■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

■■ Check with a qualified electrician if you are not sure the dryer is properly grounded.

8

GAS DRYER INSTALLATION REQUIREMENTS

Gas Supply

IMPORTANT: Observe all governing codes and ordinances.

This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

The design of this dryer has been certified by CSA International for use at altitudes up to 10,000 feet (3048 m) above sea level at the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

When installed above 10,000 feet (3048 m), a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial plate is required for each 1,000 foot (305 m) increase in elevation. For assistance when converting to other gas types and/or installing above 10,000 feet (3048 m) elevation, contact your local service company.

9

ELECTRIC DRYER INSTALLATION REQUIREMENTS

Location Requirements

The dryer must be exhausted outdoors.

Your dryer can be installed in a basement, laundry room, or recessed area.

Companion appliance location requirements should also be considered.

IMPORTANT: Do not install or store the dryer where it will be exposed to the weather. Proper installation is your responsibility.

You will need:

■■ A grounded electrical outlet located within 6 ft. (1.8 m) of where the power cord is attached to the back of the dryer. See “Electrical Requirements.”

■■ A level floor with a maximum slope of 1" (25 mm) under entire dryer. Installing the dryer on soft floor surfaces, such as carpets or surfaces with foam backing, is not recommended.

Electric dryer installation clearances

■■ The location must be large enough to allow the dryer door to be fully opened.

■■ Additional spacing should be considered for ease of installation and servicing. The door opens more than 180°.

■■ Additional clearances might be required for wall, door, and floor moldings.

■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

Recessed Area and Closet Installation Instructions

This dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer or in “Dimensions/Clearances.”

The installation spacing is in inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.

48 in.2

(310 cm2) 3"

(76 mm)

Front

 

 

 

Closet

View

 

Closet

 

Door

View

 

door

 

 

 

3" (76 mm)

24 in.2

(155 cm2)

Electrical Requirements – U.S.A. only

It is your responsibility:

■■ To contact a qualified electrical installer.

■■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

■■ The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

■■ A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

■■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

■■ Do not use an extension cord.

■■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

10

ELECTRIC DRYER INSTALLATION REQUIREMENTS

Electrical Requirements – U.S.A. only (cont.)

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

■■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

■■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

■■ A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations and (2) areas where local codes prohibit grounding through the neutral conductor.

Electric Dryer Grounding

Electric Dryer Power Supply Cord

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or “U” shaped spade terminals with upturned ends.

■■ A UL listed strain relief.

If your outlet looks like this:

4-Wire Receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The

3-wire power supply cord, at least 4 ft. (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

3-Wire Receptacle (10-30R)

11

ELECTRIC DRYER INSTALLATION REQUIREMENTS

Direct Wire

Electrical Requirements – Canada only

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

■■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit.

All current-carrying wires must be insulated.

■■ 10-gauge solid copper wire (do not use aluminum). ■■ At least 5 ft. (1.52 m) long.

It is your responsibility:

■■ To contact a qualified electrical installer.

■■ To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association,

178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

■■ To supply the required 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■■ This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-Wire Receptacle (14-30R)

■■ Do not use an extension cord.

If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in the “Assistance or Service” section.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

12

DRYER VENTING REQUIREMENTS

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

4" (102 mm)

4" (102 mm) Heavy, Metal Exhaust Vent

■■ Only a 4" (102 mm) heavy, metal exhaust vent and clamps may be used.

■■ Do not use plastic or metal foil vent.

Rigid metal vent:

■■ Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location.

■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 734 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Chart” and if necessary, modify existing vent system to achieve best drying performance.

Elbows:

■■ 45° elbows provide better airflow than 90° elbows.

Good

Better

Clamps:

■■ Use clamps to seal all joints.

■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

13

Vent Collar

DRYER VENTING REQUIREMENTS

Vent Hoods

4" (102 mm) Diameter Exhaust Hoods

Exhaust hood must be at least 12" (305 mm) from the ground or

 

any object that may be in the path of the exhaust (such as flowers,

 

rocks, bushes, or snow).

Box Hood

Louvered Hood

Angled Hood

12" min.

(305 mm)

Vent System Length

Maximum Vent Length/Vent Connection

Maximum length of vent system depends upon the type of vent used, number of elbows, and type of exhaust hood.

Vent System Chart (Rigid Metal Vent)

No. of

Box and

Angled

 

90˚ Turns

Louvered Hood

Hood

 

0

64 ft. (19.5 m)

58 ft. (17.7 m)

 

1

54 ft. (16.5 m)

48 ft. (14.6 m)

 

2

44 ft. (13.4 m)

38 ft. (11.6 m)

 

3

35 ft. (10.7 m)

29 ft. (8.8 m)

 

4

27 ft. (8.2 m)

21 ft. (6.4 m)

 

For vent systems not covered by the vent specification chart, see your parts distributor.

Provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area and Closet Installation Instructions” in the “Location Requirements” sections.

A 4" (102 mm) outlet hood is preferred. However, a 212" (64 mm) outlet exhaust hood may be used. A 212" (64 mm) outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required.

Connect Vent

1.If connecting to existing vent, make sure the vent is clean.

2.Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer.

3. Tighten hose clamp with Phillips screwdriver.

4.Make sure the vent is secured to exhaust hood with a 4" (102 mm) clamp.

5.Move dryer into final position. Do not crush or kink vent. Make sure dryer is level.

NOTE: Testing for proper ventilation should be done with a Manometer. Minimum: 0.01" (0.2 mm). Maximum: 0.6" (16 mm).

NOTE: Do not remove vent collar.

14

DRYER VENTING REQUIREMENTS

If an Exhaust Hood Cannot be Used

The outside end of main vent should have a sweep elbow directed downward.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12" min.

24" min.

 

 

 

 

 

(305 mm)*

(610 mm)

 

 

 

 

 

 

 

 

 

 

*Minimum clearance above any accumulation of snow, ice, or debris such as leaves

If main vent travels vertically through the roof, rather than through wall, install a 180° sweep elbow on end of vent at least 2 ft. (610 mm) above surface of roof.

The opening in wall or roof shall have a diameter 1⁄2" (13 mm) larger than vent diameter. Vent should be centered in opening.

Do not install screening over end of vent for best performance.

Multiple Dryer Venting

A main vent can be used for venting a group of dryers. The main vent should be sized to remove 5663 l/min. (200 CFM) of air per dryer. Large-capacity lint screens of proper design may be used in main vent if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than CFM of all the dryers in the room.

Back-draft dampers are available from your distributor and should be installed in the vent of each dryer to keep exhausted air from returning into dryers and to keep exhaust in balance within main vent. Unobstructed return air openings are required.

Although usually each single-load dryer should have an unobstructed outdoor air opening of 24 in.2 (154 cm2) (based

on 1 in.2 [6.5 cm2] per 1,000 Btu [252 kcal]), common make-up air openings are also acceptable. Set up common openings so

the make-up air is distributed equally to all of the dryers. Keep in mind that the coverage area must be increased by 33% to account for the use of registers or louvers over the openings. Also, make-up air openings should not be installed near the location where exhaust vents exit the building.

Each vent should enter the main vent at an angle pointing in

the direction of the airflow. Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents.

Air Floow

The maximum angle of each vent entering the main vent should be no more than 30°.

Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can damage dryers and items being dried.

A clean-out cover should be located on the main vent for periodic cleaning of the vent system.

NOTE: For more dryer venting information, please refer to Whirlpool document W10100920.

GAS SUPPLY CONNECTION

Make Gas Connection

1.Connect gas supply to dryer. Use a pipe thread compound approved for the type of gas supplied. If flexible metal tubing is used, be certain there are no kinks.

If necessary for service, open the toe panel. Use a putty knife to press on the toe panel lock located at the center top of the toe panel. Pull downward on the toe panel to open. Toe panel is hinged at the bottom.

2.Open the shut-off valve in the gas supply line and make sure the dryer has its own gas supply opened.

3.Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leaks found.

15

GAS SUPPLY CONNECTION

Type of Gas

This dryer is equipped for use with natural gas. It is design-certified by CSA International for LP (propane and butane) gases with appropriate conversion. No attempt shall be made to convert dryer from gas specified on serial/rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician.

Gas conversion kit part numbers are listed near gas valve burner base.

Gas Supply Line

Recommended Method

Provide a gas supply line of 1⁄2" (13 mm) rigid (IPS) pipe to dryer location. Pipe joint compounds that resist action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size can be 1⁄2" (13 mm) minimum. Usually, LP gas suppliers determine size and materials used in the system.

Gas Supply Pressure Testing

A 1/8" (3 mm) NPT minimum plugged tapping, accessible for gauge testing, must be installed immediately downstream of the installed shut-off valve to the dryer (as shown above). The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2" psig (352 kg/m2). The expected pressures for the gas supply are listed in inches of water in the table below:

 

Natural Gas

LP Gas

Minimum

5.2" (132.1 mm)

8.0" (203.2 mm)

 

 

 

Maximum

10.5" (266.7 mm)

13.0" (330.2 mm)

 

 

 

Alternate Method

The gas supply may also be connected using 3⁄8" (10 mm) approved copper or aluminum tubing. If the total length of the supply line is more than 20 ft. (6.1 m), larger tubing will be required.

If using natural gas, do not use copper tubing. Pipe joint compounds that resist action of type of gas supplied must be used.

Shut-off valve required

The supply line must be equipped with a manual shut-off valve installed within 6 ft. (1.8 m) of dryer in accordance with National Fuel Gas Code, ANSI Z223.1. This valve should be located in same room as dryer. It should be in a location that allows ease of opening and closing. Do not block access to shut-off valve. In Canada, an individual manual shut-off valve must be installed in accordance with the B149 installation codes CAN/CGA B149.1 and CAN/CGA B149.2.

Flexible Metal Appliance Connector

It is recommended that a new flexible stainless steel gas line, design-certified by CSA International, be used for connecting the dryer to the gas supply line. (The gas pipe which extends through the lower rear of the dryer is provided with 3/8" [10 mm] male pipe thread.)

NOTE: Do not kink or damage the flexible stainless steel gas line when moving the dryer.

Rigid Pipe Connection

The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the dryer.

†®TEFLON is a registered trademark of Chemours.

16

INSTALLING LEVELING LEGS, COIN SLIDE, AND COIN BOX

On some models: The console houses the electronic control board. The board is factory set for a dry time of 5 minutes. Consult the tech sheet found inside the dryer toe panel to reset dry time and for other options.

The card reading mechanism is not included, but is available from your usual industry sources.

1. Prepare dryer for leveling legs

NOTE: Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering.

Using two or more people, move dryer to desired installation location.

Take tape off front corners of dryer. Open dryer and remove

the literature and parts packages. Wipe drum interior with a damp cloth to remove any dust.

Take two cardboard corners from the dryer carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners. Disconnect power before making electrical connections.

(appearance may vary)

2. Screw in leveling legs

Examine leveling legs and find diamond marking. Screw legs into leg holes by hand. Use an adjustable wrench or

1" (25 mm) hex-head socket wrench to finish turning legs until diamond marking is no longer visible. Then fit

a covered foot boot over each leg foot.

Diamond

Marking

Foot

To protect the floor, use a large piece of cardboard from the dryer carton. Stand dryer up on the cardboard. Slide the dryer until

it is close to its final location. Leave enough room for electrical connection and to connect the exhaust vent.

A longer leveling foot is available if needed on extremely sloped floors, Part Number 279810.

On some models: The meter case houses the factory-installed accumulator timer with actuating arm or service switch.

The factory-installed timer is set to provide 45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute (6 pins) and 60-minute (3 pins) drying times are included in the parts bag.

The coin slide mechanism, service door lock and key, and coin box lock and key may not be included but are available from the usual industry sources.

1. Install coin slide and coin box

Remove the service door of the meter case by lifting it up at the back. Install the money-accepting device. (Refer to manufacturer’s instructions for proper installation.)

For dryers using coin slides, use the adapter kit supplied with the dryer.

Install the meter case service door. Put the coin box with lock and key in the meter case opening.

Remove cardboard or hardboard from under dryer. Adjust the legs of the dryer up or down until the dryer is level.

2. Install added security device

Check that power is not supplied to the dryer. Open and remove the service door.

Insert the narrow part of the security cone into the oblong hole in the bottom rear of the meter case assembly.

Pass the security bolt through this cone and thread it by hand into the cage nut below the oblong hole.

Tighten the security bolt by hand a few turns before using a wrench to tighten until snug.

Security

Bolt

Security

Cone

Cage

Nut

NOTE: Installing the security bolt provides added security, but will add to the service time when the top needs to be removed or lifted for servicing the dryer.

17

ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)

Connection Options

Power Cord

4-wire receptacle (NEMA Type 14-30R)

Go to "Power Supply Cord Connection" section.

3-wire receptacle (NEMA Type 10-30R)

Go to "Power Supply Cord Connection" section.

Direct Wire

4-wire direct

Go to "Direct Wire Connection" section.

1"

(25

mm)

 

 

 

(127

5"

 

mm)

 

 

 

3-wire direct

Go to "Direct Wire Connection" section.

NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to “Connecting 3-Wire Connection: Optional” section. This connection may be used with either a power supply cord or a direct wire connection.

Power Supply Cord Connection

Power Supply Cord Strain Relief

1. Insert strain relief.

Remove Terminal Block Cover

Remove hold-down screw and terminal block cover.

18

A

B

C

D

Remove the screws from a ¾" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections

(C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.

2. Insert power cord into strain relief.

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)

Connecting 4-Wire Connection: Power Supply Cord

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Standard Power Supply Cord Connectors

Flanged Spade Connector

Ring Connector

Connecting Neutral Ground and Neutral Wires

1.Remove center terminal block screw (A) and the neutral ground wire (B) by removing the green external ground conductor screw (C).

Connecting Power Cord Ground Wire

3.Connect ground wire (green or bare) (E) of power supply cord under green external ground conductor screw (C). Tighten screw.

E

C

B A

C

2.Connect neutral ground wire (B) and neutral wire (white or center wire) (D) of power supply cord under center terminal block screw (A). Tighten screw.

Connecting Remaining Wires

4.Connect remaining wires under outer terminal block screws

(F). Tighten screws. Finally, reinstall terminal block cover to dryer rear panel. Secure cover with hold-down screw. Now go to "Venting Requirements."

F

F

 

B

D

A

Connecting 3-Wire Connection: Power Supply Cord

Standard Power Cord Connectors

Flanged Spade Connector

Ring Connector

Connecting Neutral Wire

1. Loosen or remove center terminal block screw (A).

2.Connect neutral wire (white or center wire) (D) of power supply cord under center terminal block screw (A). Tighten screw.

D

A

A

19

ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)

Connecting 3-Wire Connection: Power Supply Cord (cont.)

3.Connect remaining wires under outer terminal block screws (F). Tighten screws. Finally, reinstall terminal block cover to dryer rear panel. Secure cover with hold-down screw. Now go to "Venting Requirements."

F

F

Direct Wire Connection

Remove Terminal Block Cover

Remove hold-down screw and terminal block cover.

20

Direct Wire Strain Relief 1. Insert strain relief.

A

B

C

Unscrew the removable conduit connector (A) and any screws from a ¾" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C)

through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads.

2. Insert conduit into strain relief and tighten clamp.

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

Loading...
+ 44 hidden pages