Maytag MEDE400WR, MEDE300VW, MEDE300VF, WED9750WR, WED9600TW Installation Instructions

...
0 (0)

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

U.S.A. ONLY

Para una versión de estas instrucciones en español, visite www.Whirlpool.com

TABLE OF CONTENTS

DRYER SAFETY..............................................................................

1

INSTALLATION REQUIREMENTS ................................................

2

Tools and Parts ............................................................................

2

Optional Equipment .....................................................................

3

Location Requirements................................................................

3

ELECTRIC DRYER POWER HOOKUP .........................................

5

Electrical Requirements ...............................................................

5

Electrical Connection ...................................................................

6

VENTING .......................................................................................

11

Venting Requirements................................................................

11

Plan Vent System.......................................................................

12

Install Vent System.....................................................................

13

INSTALL LEVELING LEGS...........................................................

13

CONNECT VENT...........................................................................

14

CONNECT INLET HOSE

 

(STEAM MODELS)........................................................................

14

LEVEL DRYER ..............................................................................

15

COMPLETE INSTALLATION .......................................................

15

TROUBLESHOOTING ..................................................................

15

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

W10255468C W10259190B - SP

Maytag MEDE400WR, MEDE300VW, MEDE300VF, WED9750WR, WED9600TW Installation Instructions

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)

Level

Wire stripper (direct wire installations)

Vent clamps

Parts supplied

Non-Steam Models

Caulking gun and compound (for installing new exhaust vent)

Tin snips (new vent installations)

¼" nut driver (recommended)

Tape measure

Pliers

4 Leveling legs

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Steam Models

A

B

C

D

E

 

A. Leveling legs (4)

 

D. Long inlet hose

 

 

B. “Y” connector

 

E. Rubber washer

 

 

C. Short inlet hose

 

 

 

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your Use and Care Guide.

2

Optional Equipment

Refer to your Use and Care guide for information about the accessories available for your dryer.

Location Requirements

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to the bottom of the dryer.

Steam models only: Cold water faucets located within 4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the cold water supply from your washer using the “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic sensor cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

D

A

B C

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A

38" (965 mm)

38" (965 mm)

 

 

 

B

32 9/16" (827 mm)

31 1/2" (800 mm)

 

 

 

C

27" (686 mm)

27" (686 mm)

 

 

 

D

52 9/16" (1335 mm)

51 1/2" (1308 mm)

NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow.

Venting Dimensions

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

 

 

 

Non-Steam

 

(Electric or Gas)

 

(Electric or Gas)

 

 

 

 

 

 

 

 

 

A*

 

1" (25 mm)

 

 

 

1" (25 mm)

 

 

 

 

 

 

B

14" (356 mm)

 

14" (356 mm)

 

 

 

 

 

 

C

3 7/16" (87 mm)

 

3 7/16" (87 mm)

*Dimension A is approximate, depending on when the diamond marking on the leveling foot is no longer visible.

3

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A*

 

 

 

 

 

 

 

 

 

 

 

 

 

Side View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

1" (25 mm)

1" (25 mm)

 

 

 

B

7 5/8" (194 mm)

7 5/8" (194 mm)

 

 

 

C

3 3/8" (86 mm)

3 3/8" (86 mm)

*Dimension A is approximate, depending on when the diamond marking on the leveling foot is no longer visible.

See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

A

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C*

 

 

 

 

D

 

 

E*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

 

 

 

Non-Steam

 

 

(Electric or Gas)

 

 

 

(Electric or Gas)

 

 

 

 

 

 

 

 

 

A

 

 

 

0" (0 mm)

 

 

 

0" (0 mm)

 

 

 

 

 

 

 

 

 

B

 

 

 

38" (965 mm)

 

 

 

38" (965 mm)

 

 

 

 

 

 

 

 

 

C*

 

 

 

1" (25 mm)

 

 

 

1" (25 mm)

 

 

 

 

 

 

 

 

 

D

 

 

 

27" (686 mm)

 

 

 

27" (686 mm)

 

 

 

 

 

 

 

 

 

E*

 

 

 

1" (25 mm)

 

 

 

1" (25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Required spacing

NOTE: Some models are not recommended for undercounter installation.

Closet installation - Dryer only

 

(460 mm)

A*

B

C**

 

Side view

Closet door with vents

 

 

 

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

1" (25 mm)

1" (25 mm)

 

 

 

B

32 9/16" (827 mm)

31 1/2" (800 mm)

 

 

 

C**

5" (127 mm)

5" (127 mm)

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

A

B

C

 

(460 mm)

 

D*

E

F**

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A

1" (25 mm)

1" (25 mm)

 

 

 

B

27" (686 mm)

27" (686 mm)

 

 

 

C

1" (25 mm)

1" (25 mm)

 

 

 

D*

1" (25 mm)

1" (25 mm)

 

 

 

E

32 9/16" (827 mm)

31 1/2" (800 mm)

 

 

 

F**

5" (127 mm)

5" (127 mm)

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed

NOTE: Some models are not recommended for recessed or closet installation.

4

Recommended installation spacing for cabinet installation

NOTE: Some models are not recommended for cabinet installation.

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

A* B*

 

 

 

 

C*

D**

E

F* G

H

I

 

 

Steam

Non-Steam

 

(Electric or Gas)

(Electric or Gas)

 

 

 

A*

7" (178 mm)

7" (178 mm)

 

 

 

B*

7" (178 mm)

7" (178 mm)

 

 

 

C*

9" (229 mm)

9" (229 mm)

 

 

 

D**

5" (127 mm)

5" (127 mm)

 

 

 

E

32 9/16" (827 mm)

31 1/2" (800 mm)

 

 

 

 

F*

1"

(25 mm)

1" (25 mm)

 

 

 

 

G

1"

(25 mm)

1" (25 mm)

 

 

 

 

H

27"

(686 mm)

27" (686 mm)

 

 

 

 

I

1"

(25 mm)

1" (25 mm)

 

 

 

 

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

48 in.2 * (310 cm2)

3"* (76 mm)

 

3"* (76 mm)

24 in.2 *

1"* (25 mm)

(155 cm2)

 

6"* (152 mm)

76" (1930 mm)

A*

 

 

 

 

1"

 

 

 

27"

 

 

1"

 

 

 

 

 

 

 

 

 

 

(25 mm)

(686 mm)

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

Steam

 

 

Non-Steam

(Electric or Gas)

 

 

(Electric or Gas)

 

 

 

 

 

A*

5 ½" (140 mm)

 

 

5" (127 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

*Required spacing

NOTE: Some models are not recommended for stacked recessed or closet installation.

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers:
Metal exhaust system hardware, which is available for purchase from your dealer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

ELECTRIC DRYER POWER

HOOKUP

Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.