ELECTRIC DRYER INSTALLATION INSTRUCTIONS
U.S.A. ONLY

Para una versión de estas instrucciones en español, visite www.Whirlpool.com

TABLE OF CONTENTS

DRYER SAFETY..............................................................................1
INSTALLATION REQUIREMENTS ................................................2
Tools and Parts ............................................................................ 2
Optional Equipment .....................................................................3
ELECTRIC DRYER POWER HOOKUP
.........................................5
Electrical Requirements ............................................................... 5
Electrical Connection ................................................................... 6
VENTING .......................................................................................11
Venting Requirements................................................................11
Plan Vent System .......................................................................12
Install Vent System.....................................................................13
INSTALL LEVELING LEGS...........................................................13
CONNECT VENT...........................................................................14
CONNECT INLET HOSE (STEAM MODELS)..
............................14
LEVEL DRYER ..............................................................................15
COMPLETE INSTALLATION .......................................................15
TROUBLESHOOTING ..................................................................15
W10471644B
W10
471646B - SP

DRYER SAFETY

You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
2

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
(for adjusting dryer feet)
Level
Wire stripper (direct wire
installations)
Vent cl amps
Caulking gun and compound
(for installing new exhaust
vent)
Tin snips (new vent
installations)
1/4" nut driver
(recommended)
Tap e me as u re
Pliers

Parts supplied

Non-Steam Models

4 Leveling legs
Remove parts package from dryer drum. Check that all parts are
included.
NOTE: Do n
ot use leveling legs supplied with dryer if installing
on a pedestal.

Steam Models

A. Leveling legs (4)
B. “Y” connector
C. Short inlet hose
D. Long inlet hose
E. Rubber washer
Remove parts package from dryer drum. Check that all parts are
included.
NOTE: Do n
ot use leveling legs supplied with dryer if installing
on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements” before
purchasing parts.
Mobile home installations require m
etal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please refer to the “Assistance
or Service” section in your Use and Care Guide.
3

Optional Equipment

Refer to your Use and Care guide for information about the
accessories available for your dryer.

Location Requirements

You will need

A location that allows for proper exhaust installation. See
“Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the dryer.
See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance
should
also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer
Feet Kit, Part Number 279810. Clothes may not tumble properly
and automatic sensor cycles may not operate correctly if dryer is
not level.
For a garage installation, you will need to place the dryer at least
18" (460 mm) above the floor. If using a pedestal, you will need
18" (460 mm) to the bottom of the dryer.
Steam models only: Cold water faucets located within
4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi
(137.9-689.6 kPa). You may use the cold water supply from
your washer using the “Y” connector provided.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic sensor cycle. This can result in longer drying times.
The dryer must not be installed or st
ored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or
do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
A
B
C
D
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A 38" (965 mm) 38" (965 mm)
B 32
9
/16" (827 mm) 31
1
/2" (800 mm)
C 27" (686 mm) 27" (686 mm)
D 52
9
/16" (1335 mm) 51
1
/2" (1308 mm)
NOTE: Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow.
Venting Dimensions
C
B
A
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 14" (356 mm) 14" (356 mm)
C 3
7
/16" (87 mm) 3
7
/16" (87 mm)
Back View
* Dimension A is approximate, depending on when the diamond
marking on the leveling foot is no longer visible.
B
C
A
4
Side View
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 7
5
/8" (194 mm) 7
5
/8" (194 mm)
C 3
3
/8" (86 mm) 3
3
/8" (86 mm)
* Dimension
A is approximate, depending on when the diamond
marking on the leveling foot is no longe
r visible.
See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on the
sides an
d rear. Recommended spacing should be considered for the
following reasons:
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and floor
moldings.
Additional spacing should be considered on all sides of the dryer
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
A
B
C* DE*
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A 0" (0 mm) 0" (0 mm)
B 38" (965 mm) 38" (965 mm)
C* 1" (25 mm) 1" (25 mm)
D 27" (686 mm) 27" (686 mm)
E* 1" (25 mm) 1" (25 mm)
*Required spacing
NOTE:
Some models are not recommended for undercounter
installation.
Closet installation - Dryer only
A*
B C**
(460 mm)
Side view
Closet door with vents
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 1" (25 mm) 1" (25 mm)
B 32
9
/16" (827 mm) 31
1
/2" (800 mm)
C** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
Recessed or closet installation
- Dryer on pedesta
A
B C D* E
F**
(460 mm)
l
Steam
(Electric or G
as)
Non-Steam
(Electric or Gas)
A 1" (25 mm) 1" (25 mm)
B 27" (686 mm) 27" (686 mm)
C 1" (25 mm) 1" (25 mm)
D* 1" (25 mm) 1" (25 mm)
E 32
9
/16" (827 mm) 31
1
/2" (800 mm)
F** 5" (127 mm) 5" (127 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed
NOTE: Some
models are not recommended for recessed or closet
installation.
5
Recommended installation spacing for cabinet
installation
NOTE: Some models are not recommended for cabinet installation.
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
A*
B*
C*
D**
E
F*
H
I
G
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 7" (178 mm) 7" (178 mm)
B* 7" (178 mm) 7" (178 mm)
C* 9" (229 mm) 9" (229 mm)
D** 5" (127 mm) 5" (127 mm)
E 32
9
/16" (827 mm) 31
1
/2" (800 mm)
F* 1" (25 mm) 1" (25 mm)
G 1" (25 mm) 1" (25 mm)
H 27" (686 mm) 27" (686 mm)
I 1" (25 mm) 1" (25 mm)
*Required spacing
**For side or bottom venting, 0" (0 mm) spacing is allowed.
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 in.
2
*
(310 cm
2
)
3"* (76 mm)
3"* (76 mm)
1"* (25 mm)
24 in.
2
*
(155 cm
2
)
6"* (152 mm)
76"
(1930 mm)
27"
(686 mm)
A*
1"
(25 mm)
1"
(25 mm)
Steam
(Electric or Gas)
Non-Steam
(Electric or Gas)
A* 5 ½" (140 mm) 5" (127 mm)
*Required spacing
NOTE: Some
models are not recommended for stacked recessed or
closet installation.

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part 280) or
Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All Dryers:
Metal exhaust system hardware, which is available for purchase
from your dealer.
Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.
ELECTRIC DRYER POWER
HOOKUP

Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70 -
latest edition and all local codes and ordinances.
The National Electrical Code r
equires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved in
remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
Na
tional Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.