Room Air Conditioner
(Window Type)
OWNER'S MANUAL
Troubleshooting Tips Installation Instructions Operating Instructions Safety Precautions
Safety precautions
Safety Precautions ............. |
3 |
Operating instructions
About the Controls on the Air |
|
Conditioner ......................... |
5 |
Care and Maintenance ....... |
8 |
Installation Instructions
Features............................... |
9 |
Installation Instructions......... |
9 |
Troubleshooting tips
Before You
Call for Service.................. |
11 |
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
CAUTION
Contact the authorized service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
-2-
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.
WARNING |
: This symbol shows the possibility of causing death or serious injury. |
CAUTION |
This symbol indicates the possibility of injury or damage to |
: properties only. |
The items to be followed are classified by the following symbols.
Never Do This
Always Do This
The airconditioner should be installed in accordance with national wiring regulation Following circuit breaker/fuse rating to be used as per unit specification
LW-C12..CI(12000 Btu/Hr) 15A, LW-N18..CI(18000 BTu/Hr )-20A ,LW-N24..CI(24,000 Btu/Hr )-30A
WARNING
Plug in the power plug properly.
Otherwise, it will cause electric
shock or fire due to heat
generation or electrical shock.
Do not modify power cord length or share the outlet with other appliances.
It will cause electrical shock or
fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electrical shock or
fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electrical shock.
Do not damage or use an unspecified power cord.
It will cause electrical shock or fire.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
Do not direct airflow at room occupants only.
This could damage your health.
Precautions Safety
If your airconditioner is not provided with a plug then there should be some means for disconnection of both live & neutral poles having a contact seperation of minimum 3mm & must be Incorporated in fixed wiring in accordance to wiring rules
-3-
Safety Precautions
Never touch the metal parts of the unit when removing the filter.
It may cause an injury.
When cleaning the unit, first make sure the power and breaker are turned off.
Since the fan rotates at high
speed during operation, it may
cause an injury.
Do not operate Switches with wet hands.
CAUTION
Do not clean the air |
|
Ventilate well when used |
conditioner with water. |
|
together with a stive, etc. |
|
|
|
Water may enter the unit and |
|
An oxygen shortage may occur. |
degrade the insulation. It may |
|
|
cause an electric shock. |
|
|
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not apply an insecticide or flammable spray.
Do not use for special purposes.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.
It may cause deterioration of quality, etc.
Do not put a heater, etc. where is exposed to direct air flow.
It may cause an electric shock. |
It may cause a fire or deformation |
It may cause imperfect |
|
of the cabinet. |
combustion. |
-4-
-5- |
Operating Instructions
Controls
Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner.
POWER BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
Select Cooling Fan or Dehumidification (Dry) mode with this button.
ON/OFF TIMER/SLEEP BUTTON
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In the first 30 minutes set temperature increases by 1°C and in the next 30 minutes temperature increases by another 1°C, this temperature then remains till the timer function is activated. This is how the sleep function behaves.
FAN SPEED SELECTOR
Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3)
ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 16°C to 30°C.
AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
SIGNAL RECEIVER
ENERGY SAVER
The fan stops when the compressor stops cooling. Approximately even 3 minutes the fan will turn on and check the room air to determine if cooling is needed.
FOR PLASMA MODELAIR PURIFIER
Used to Start or Stop the Plasma Purification function
AUTO RESTART
In failure of electric power the unit runs as previous setting operation when power returns.
How to Insert the Batteries
Remove the cover from the back of the remote controller.
Slide the cover according to the arrow direction.
Insert the two batteries.
Be sure that the (+) and (-) directions are correct.
Be sure that both batteries are new.
Re-attach the cover.
Slide it back into the position.
-6-
Do not use rechargeable batteries, such batteries differ from standard dry cells in shape, dimensions, and performance.
Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time.