Please read this manual carefully before operating your set and retain it for future reference.
NORSK SUOMI DANSK
TYPE :
P/NO : MFL69365403
WINDOW
www.lg.com
Safety Precautions
Before Operation
Introduction
Safety
Installation
Operating Instructions
Maintenance and Service
7
16
20
Do not store flammables like gasoline benzene thinner etc. near the air conditioner.
No correlation between fan usage and oxygen depletion.
Unplug the unit when not using it for a long time.
Hold the plug by the head
not the cablewhen taking
it out.
For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of prod
When gas leaks, open the window for ventilation before operating the unit.
uct, fire, or electric shock.
Never touch the metal parts of the unit when removing the filter.
Install the product so the exhaust and noise are not aimed directly at the neighbors.
Be considerate.
Follow installation instructions exactly.
Do not use this appliance for special purposes such as
cooling pets
foods
precision
machinery,or objects of art
Instead of running air conditioning constantly for fresh air occasionally.
You will feel better.
If the liquid from the battery gets onto your skin or clothers
wash it well with clean water. Do
not use the remote if the battery has leaked.
y
open a window
If you eat the liquid from the battery,brush your teeth and see doctor.Do not use the
remote if the battery has leaked.
y
2. No correlation between fan usage and oxygen depletion.
3.
RESET
TEST
USE OF EXTENSION CORDS
RISK OF FIRE could cause serious injury or death DO NOT use an extension cord with this window air conditioner DO NOT use surge protectors or multi-outlet adapters with this window air conditioner
should
be
Avoid shock hazard. This unit cannot be user-serviced. Do NOT open the tamper-resistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
WARNING
1.Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer
2.The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater)
3.Do not pierce or burn. Be aware that refrigerants may not contain an odor
This unit contains flammable refrigerant and has special safety precautions not normally associated
with older units. Please follow all precautions and advisories.
1. Use caution while handling and prevent damage to unit.Do not put any holes into product for any reason, this can cause damage to product and prevent unit from cooling.
2. Maintenance and cleaning of unit should be performedby trained personnel. Failure to properly clean unit can result in damage to the refrigeration system and or the electrical system.
3. Make certain that all the air circulation/ventilation openings are free from obstruction.
4. Service should only be performed by technicains properly trained and certified in the use of flammable refrigerants. Any service performed by unauthorized servicers/individuals will void all warranties.
5. When storing the appliance, do not put in a room with any open flame appliances, such as gas water heaters or furnaces. Also keep away from electric heaters. Damaged units should be repaired before storage.
14 EA
3 EA 5 EA
2 EA
2 EA
(Not adhesive backed)
1 EA
2 EA
Phillips head screwdriver
2 EA
1 EA
1 EA
Left Guide Panel
( Adhesive backed)
EA
2 EA
Right Guide Panel
Curtain
FOAM-HEATPROOF
Scissors or knife
Adjustable Wrench
11
slightly tilted
between
Preparation Of Chassis
Remove 4 screws which fasten the cabinet at both sides and at the back.
(Keep the screws for later use.)
27 39
16
12
(Adhesive backed)
and bottom of window frame.
the base pan
Adhesive backed
guide
hole
frame curtain
sill support.
Upper guide
Left Guide panel
Right Guide Panel
8
Screws
(Type A)
Frame guide
upper
Center hole
13
frame guides
sill support
frame curtain
frame curtain
sill support
14
(removed from the cabinet) at
See page 12.
Not adhesive backed
Foam-Strip
(Not adhesive backed)
Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.
14
Cut the adhesive-backed Foam­Heatproofs to the Guide Panel size.
Remove the backing from the Foam-Heatproofs and attach the Foam-Heatproofs to Guide Panel.
Foam-Heatproof improves the cooling capability of the unit.
15
Attach the front grille to the cabinet by inserting the tabs the grille into the slots on the front the cabinet.Push the grille in until it snaps into place.
Guide the lever carefully through the
grille as you push it in.
16
Take out the air filter and secure it with 2 Type A screws through the front grille.
These 2 Type A screws are packaged by bag.
Foam-Heatproof
Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet.
15