LG JTNQ24GPLE5 Owner’s Manual

0 (0)
LG JTNQ24GPLE5 Owner’s Manual

OWNER’S MANUAL

ROOM AIR

CONDITIONER

4-WAY CEILING CASSETTE

MFL67850901

<![if ! IE]>

<![endif]>ENGLISH

2TABLE OF CONTENTS

TABLE OF CONTENTS

3TIPS FOR SAVING ENERGY

4IMPORTANT SAFETY INSTRUCTIONS

7BEFORE USE

7Preparing for operation

7Usage

7Cleaning and maintenance

7Service

8PRODUCT INTRODUCTION

8Name and function of parts

9 Operation Indication Lamps

10 Wireless Remote Controller

12OPERATING INSTRUCTION

12 How to insert the Batteries

12Wireless Remote Controller Maintenance

13INSTALLATION

INSTRUCTIONS

13Installer Setting -

How to enter installer setting mode

14Installer Setting -

Installer Setting Code Table

15Installer Setting -

Setting Address of Central Control

15Installer Setting -

Checking Address of Central Control

16OWNER'S INSTRUCTION

16Cooling Mode - Standard Operation

16Cooling Mode - Power Cooling

17Auto Operation Mode

18Dehumidification Mod

19Fan Mode

20Temperature Setting/

Room Temperature checking

21Airflow Setting

22Plasma PurificationOptional)

22Celsius/Fahrenheit Switching

23Individual vane angle control

24Timer

25MAINTENANCE AND

SERVICE

25Indoor Unit

26Purifying filer(Optional)

27Operation Tips!

27When the air conditioner is not going....

28Troubleshooting Tips! Save time and money!

28Call the service immediately in the following situations

TIPS FOR SAVING ENERGY

3

 

TIPS FOR SAVING ENERGY

Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:

Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.

<![if ! IE]>

<![endif]>ENGLISH

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

<![if ! IE]>

<![endif]>ENGLISH

4IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product

! WARNING

It can result in serious injury or death when the directions are ignored

! CAUTION

It can result in minor injury or product damage when the directions are ignored

!WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

The product shall be installed according to the Wiring regulations of the corresponding country.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product. There is risk of fire or electric shock.

Always ground the product. There is risk of fire or electric shock.

Install the panel and the cover of control box securely. There is risk of fire or electric shock.

Always install a dedicated circuit and breaker. Improper wiring or installation may cause fire or electric shock

Use the correctly rated breaker or fuse. There is risk of fire or electric shock.

Do not modify or extend the power cable. There is risk of fire or electric shock.

Do not install, remove, or re-install the unit by yourself (customer). There is risk of fire, electric shock, explosion, or injury.

Be cautious when unpacking and installing the product. Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.

For installation, always contact the dealer or an Authorized Service Center. There is risk of fire, electric shock, explosion, or injury.

Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product.

Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture.

IMPORTANT SAFETY INSTRUCTIONS

5

 

Operation

Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk of fire or electric shock.

Do not place anything on the power cable. There is risk of fire or electric shock.

Do not plug or unplug the power supply plug during operation. There is risk of fire or electric shock.

Do not touch(operate) the product with wet hands. There is risk of fire or electrical shock.

Do not place a heater or other appliances near the power cable. There is risk of fire and electric shock.

Do not allow water to run into electric parts. It may cause There is risk of fire, failure of the product, or electric shock.

Do not store or use flammable gas or combustibles near the product. There is risk of fire or failure of product.

Do not use the product in a tightly closed space for a long time. Oxygen deficiency could occur.

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Do not use the telephone or turn switches on or off. There is risk of explosion or fire

If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire.

Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives. There is risk of property damage, failure of product, or electric shock.

Do not open the inlet grill of the product during operation.(Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.

When the product is soaked (flooded or submerged), contact an Authorized Service Center. There is risk of fire or electric shock.

Be cautious that water could not enter the product. There is risk of fire, electric shock, or product damage.

Ventilate the product from time to time when operating it together with a stove, etc. There is risk of fire or electric shock.

Turn the main power off when cleaning or maintaining the product. There is risk of electric shock.

When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. There is risk of product damage or failure, or unintended operation.

Take care to ensure that nobody could step on or fall onto the outdoor unit. This could result in personal injury and product damage.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

6IMPORTANT SAFETY INSTRUCTIONS

! CAUTION

Installation

Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product.

Install the drain hose to ensure that water is drained away properly. A bad connection may cause water leakage.

Keep level even when installing the product. To avoid vibration or water leakage.

Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors.

Use two or more people to lift and transport the product. Avoid personal injury.

Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Operation

Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.) This could harm to your health.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. There is risk of damage or loss of property.

Do not block the inlet or outlet of air flow. It may cause product failure.

Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric shock, or damage to the plastic parts of the product.

Do not touch the metal parts of the product when removing the air filter. They are very sharp! There is risk of personal injury.

Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and failure of product.

Always insert the filter securely. Clean the filter every two weeks or more often if necessary. A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

Do not insert hands or other objects through the air inlet or outlet while the product is operated. There are sharp and moving parts that could cause personal injury.

Do not drink the water drained from the product. It is not sanitary and could cause serious health issues.

Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. There is risk of fire or explosion

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.

BEFORE USE

7

 

BEFORE USE

Preparing for operation

Contact an installation specialist for installation.

Use a dedicated circuit.

Usage

Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.

Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.

Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.

Cleaning and maintenance

Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.

Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.

When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit.

Service

For repair and maintenance, contact your authorized service dealer.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

8PRODUCT INTRODUCTION

PRODUCT INTRODUCTION

Name and function of parts

6 7

5

2

1

4

3

8

1.Indoor unit

2.Outdoor unit

3.Remote controller

4.Inlet air

5.Discharge air

6.Refrigerant piping, connection electric wire

7.Drain pipe

8.Ground wire

Wire to ground outdoor unit to prevent electrical shocks.

Disposal of your old appliance (as per e-waste Rules)

1.When this crossed out wheeled bin symbol is depicted on the product and its operator’s manual, it means the product is covered by the e-waste Management and Handling Rules , 2011 and are meant to be recycled, dismantled, refurbished or disposed off.

2.Dos

a.

The product is required to be handed over only to the

 

authorized recycler for disposal.

b.

Keep the product in isolated area, after it becomes

 

nonfunctional/un-repairable so as top revent its accidental

 

breakage.

Don’t

a.The product should not be opened by the user himself/herself, but only by authorized service p e rsonnel.

b.The product is not meant for re-sale to any unauthorized agencies/scrap dealer/kabariwalah.

c.The product is not meant for mixing into household waste stream.

d.Do not keep any replaced spare part(s) from the product in exposed area.

3.Any disposal through unauthorized agencies/person will attract action under Environment (Protection) Act 1986.

4.Hazards of improper handling or accidental breakage.

a.If batteries are disposed incorrectly, it can greatly harm the environment. The chemical by-products are hazardousT. he metals and chemicals found in batteries can mix into soil which may be hazardous to humans, plants and animals. If thrown in fire, they can cause blast and release toxic gases which may be harmful for health.

b.The refrigerant (R410A) used can be combustible at low pressure. The potential health effects of over exposure isd izziness, headache and heart irregularities.

5.To locate a nearest collection centre or call for pick-up (limited area only) for disposal of this appliance, please contact Toll Free No.1800-180-3575 for details. All collection centre and pick up facilities are done by third parties with LG Electronics India Pvt. Ltd. merely as a facilitator.

For more detailed information, please visit : http://www.lge.com/in

vius iqjkus midj.k dk fuiVku ¼bZ&vif’k"V fu;e ds vuqlkj½

1- tc bl dkVs x;s ifg;s okys fcu dk fpº+u fdlh midj.k vkSj blds vksisjVj dh iqfLrdk ds lkFk layXu gksrk gSa rks bldk eryc gS fd bls "bZ&vif'k"V" ¼izca/ku vkSj gFkkyu½ fu;e 2011 ds vUrxZr lfEefyr fd;k x;k gS] vkSj bls uohuhdj.k] fo?kVu vkSj fuiVku ds fy, cuk;k x;k gSA

2- djsa&

d& midj.k dks flQZ vf/kd`r iqu% uohuhdj.kdrkZ dks gh fuiVkj.k djus gsrq gLrkarfjr djsaA

[k& tc midj.k dk;Zjr u gks bls vyx {ks= esa j[kas rkfd midj.k ls gksus okyh nq?kZVukvks ls cpk tkldsA

uk djsa&

d& bl midj.k dks Lo;a/[kqn ugha [kksyuk pkfg,! midj.k dks dsoy vf/kd`r vf/kdkjh ds }kjk gh [kksyk tkuk pkfg,A

[k&bl midj.k dks iuq % fcØh ds fy, fdlh Hkh dckMh+ okyk@Hkxa kj okyk@vukf/kdr` lLa Fkk dks u nAas x& bl midj.k dks fdlh ?kjsyw vif'k"V lkeku ds lkFk feykdj u j[ksaA

?k& midj.k ds cnys gq, ;k vkrafjd iqjtks dks [kqys {ks= esa u j[ksaA

3- ;fn fdlh vukf/kd`r foHkkx ;k O;fDr ds }kjk fuiVkj.k fd;k tkrk gS rks ;g i;kZoj.k ¼lqj{kk½ /kkjk 1986 ds vUrxZr vkrk gSA

4- nq?kZVukxzLr VwV@QwV rFkk vO;ofLFkr j[k&j[kko ls cps A

d& ;fn cSVfj;ksa dk fuiVkj.k v'kq) :i ls dj jgs gaS] rks ;g okrkoj.k dks cgqr uqdlku igqq¡pk ldrk gSaA jklk;fud midj.k [krjukd gksrs gaSA tks jlk;u vkSj /kkrq cSVfj;ksa esa ik, tkrs gaS] bls feV~Vh esa feykus ij ;g euq";ksa] ikS/kksa vkSj i'kqvksa ds fy, [krjukd gks ldrh gaSA ;fn bls vkx esa Qsadrs gaS rks ;s foLQksV dj ldrh gaS vkSj ;s tgjhyh xSlsa ns ldrk gS tks LokLF; ds fy, gkfudkjd gaSA

[k& jsÝhtjsaV ¼R410A½ de ncko ij ngu'khy gks ldrh gaS rFkk blls LokLF; ij nqLizHkko iM+ ldrk gS tSls pDdj vkuk] flj nnZ vkSj g`n; xfr :dukA

5- mijksDr inkFkksZ ds fuiVkju ds fy, utnhdh fuiVkju laLFkku ¼ladh.kZ {ks=½ esa dkWy djsaA vf/kd tkudkjh ds fy, gekjs Vksy Ýh uEcj 1800-180-3575 ij dkWy djsaA lHkh laxzg.k dsUnz o fid&vi dh lqfo/kk,a FkMZ&ikVhZ ls tks "LG Electronics India Pvt. Ltd" dks viuh lsok,a iznku dj jgh gksa] ls djok,aA

vf/kd tkudkjh ds fy, ns[ksa osclkbV % http://www.lge.com/in

Operation Indication Lamps

PRODUCT INTRODUCTION 9

<![if ! IE]>

<![endif]>ENGLISH

 

1

2

3

4

5

6

1

Forced operation : Operation procedures when remote control can’t be used.

2

Defrost Mode : Lights up during defrost mode or hot start operation.

 

 

(heat pump model only)

 

 

 

3

Timer : Lights up during timer operation.

 

 

 

4 Signal Receptor : Receives the signal from remote control (signal receiving sound: two short beeps and one long beep)

5 Filter sign : Lights up after 2400 hours from the time of first operation.

6 On/Off : Lights up during system operation.

<![if ! IE]>

<![endif]>ENGLISH

10 PRODUCT INTRODUCTION

Wireless Remote Controller

This air-conditioner is equipped with wireless remote controller basically. But if you want to be available with wired remote controller, you pay for it.

1

 

2

10

 

11

3

12

4

13

5

 

6

14

7

15

8

 

16

9

17

 

VANE ANGLE Button

Used to set each vane angle.

FUNCTION SETTING Button

Used to set or clear Auto Clean, Smart Clean, Electric heater or Individual vane angle control.

ON/OFF Button

Used to turn on/off the unit.

JET COOL Button

Speed cooling operates super high fan speed.

LEFT/RIGHT AIRFLOW Button (OPTIONAL)

Used to set the desired left/right(horizontal)

airflow direction.

UP/DOWN AIRFLOW Button

Used to stop or start louver movement and set the desired up/down airflow direction.

ON TIMER Button

Used to set the time of starting operation.

SLEEP TIMER Button

Used to set the time of sleeping operation.

SET / CLEAR Button

Used to set/clear the timer.

Used to set the current time(if it input for 3sec.)

Operation Mode

Cooling Mode

Auto Operation Mode

Dehumidification mode

Fan Mode

PLASMA Button (OPTIONAL)

Used to start or stop the plasma-purification

function.

ROOM TEMPERATURE SETTING Button

Used to select the room temperature.

OPERATION MODE SELECTION Button

Used to select the operation mode.

INDOOR FAN SPEED SELECTION Button

Used to select fan speed in four steps low,

medium, high and chaos.

ROOM TEMPERATURE CHECKING Button

Used to check the room temperature.

OFF TIMER Button

Used to set the time of stopping operation.

TIMER SETTING(Up/Down)/LIGHT Button

Used to set the timer.

Used to adjust the brightness.(if it is not time

adjust mode)

RESET Button

Used to reset the remote controller.

! CAUTION

Caution of handling the Remote Controller

Aim at the signal receiver on the wired remote controller so as to operate.

The remote control signal can be received at a distance of up to about 7m.

Be sure that there are no obstructions between the remote controller and the signal receptor.

Do not drop or throw the remote controller.

Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other heat source.

Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:electronic quick start, ELBA, inverter type fluorescent lamp)

!NOTE

The wireless remote controller do not operate the swirl mode.(4Way Type)

For more details refer to the Wireless Remote Control Accessory manual.

The actual product can be different from above contents depending upon model type.

PRODUCT INTRODUCTION 11

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

12 OPERATING INSTRUCTION

OPERATING INSTRUCTION

How to insert the Batteries

Remove the battery cover by pulling it according to the arrow direction.

Insert new batteries making sure that the (+) and (-) of battery are installed correctly.

Reattach the cover by sliding it back into position.

Wireless Remote Controller

Maintenance

Choose a suitable place where its safe & easy to reach.

Fix the holder to wall etc with the supplied screws firmly.

Slide the remote controller inside the holder.

! NOTE

! NOTE

Always use/replace both batteries of same type.

If the system is not to be used for a long time, remove the batteries to save their working life.

If the display screen of remote controller starts, fading replace both of the batteries.

Remote controller should never be exposed to direct sunlight.

Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.

In case some other appliances also get operated with remote control, change their position or consult your serviceman.

INSTALLATION INSTRUCTIONS 13

INSTALLATION INSTRUCTIONS

Installer Setting - How to enter installer setting mode

! CAUTION

Installer setting mode is to set the detail function of the remote controller.

If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided.

1. With the JET COOL button pressed, press the RESET button.

2. By using the TEMPERATURE SETTING button, set function code and setting value. (Please refer the Installer Setting Code Table.)

3. Press the ON/OFF button toward the indoor unit 1 time.

4. Reset the remote controller to use the general operation mode.

Refer to the Installer Setting Code Table on the next page.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

14 INSTALLATION INSTRUCTIONS

Installer Setting - Installer Setting Code Table

Installer Setting Code Table

No.

Function

Function Code

 

Setting Value

Remote Controller LCD

 

 

 

 

 

 

0

Mode Override

0

0

: Set to Master

 

 

 

 

1

: Set to Slave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

: Standard

 

 

 

 

 

 

 

1

Ceiling Height

1

2

: Low

 

 

 

 

Selection

3

: High

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

: Super High

 

 

 

 

 

 

 

 

 

 

0

: Set to Master

 

 

 

2

 

 

 

Group Control

1 : Set to Slave

 

2

 

 

2

: Check Master/Slave

 

 

 

 

 

 

 

 

3

: Set to Auxiliary heater

 

 

 

 

 

 

 

2

 

 

 

Auxiliary heater

4 : Cancel Auxiliary heater

 

 

 

 

5

: Check Auxiliary heater Installation

 

 

 

 

 

 

 

Mode Override

This Function is only for Non-Auto Changeover H/P model.

Ceiling Height Selection

Our products provide variety of air volumes and capacities according to the selection of ceiling heights.

Cooling/Heating performance is enhanced with relation to ceiling height.

-The highest/cooling heating performance and efficiency are provide at super high. (Some noise may be generated according to the level height setting.)

Group Control

This function is only for group control. Please don’t set this function in case of non-group control.

After setting Group Control of the product, turn off the power then turn it back on after 1 minute.

Auxiliary heater

This function is only applied to models with Auxiliary Heater function being activated.

Loading...
+ 30 hidden pages