General precautions
At star tup and during operation, be sure to check that the
functions and performance of the N-UB is operating properly.
We recommend that you take substantial safety measures to
avoid any damage in the event a problem occurs.
If the N-UB is modified or used in any way other than described in
the specifications, its function and performance cannot be guaranteed.
When th e N-UB is used in combination with other instruments, the
function and performance may be effected by operating conditions and the surrounding environment.
Do not use the N-UB for the purpose of protecting the human
body.
The information contained in this manual is subject to change
without notice.
Notice
When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
For use under circumstances or environments which are not
described in the manual
For use with nuclear power control, railway, aircraft, vehicles,
incinerators, medical equipment, entertainment equipment, safety devices etc.
For use in applications where death or serious proper ty damage is
possible and extensive safety precautions are required.
For properly using the product
Do not install the N-UB in the following locations:
Locations subject to direct sunlight
Locations where the surrounding air temperature is outside the
range of 0 to +50C or locations subject to condensation as the result of severe changes in temperature
Locations where the ambient humidity is outside the range of 35
to 85%RH.
Locations subject to corrosive or flammable gases
Locations subject to dust, salts, iron dust, or oil smoke
Locations subject to shock or vibration
Locations subject to exposure of water, oil, or chemicals
Locations where strong magnetic or electric fields are generated

UL certification

The N-UB complies with the following UL/CSA standards and has obtained the UL/C-UL certification.
Applicable standard UL508, UL60950-1
UL File No. E207185, E167973
UL category NRAQ/NRAQ7, NWGQ2/NWGQ8
Be sure to observe the following installation and environment conditions.
Pollution degree 2
Overvoltage category I
Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max.
FCC regulations
The N-UB complies with the following FCC EMI regulations.
FCC Part 15 Subpart B, Class B digital device

Canada IC (Industry Canada) regulations

The N-UB complies with the following IC EMI regulations.
ICES-003, Class B digital apparatus
CE marking
The N-UB complies with the following essential requirements of the EU Directive.
EMC Directive (2004/108/EC)
The following harmonized standards are applied to this product in order to confirm the compliance.
Applicable standards (EMI) EN55011, Class A
EN55022, Class B
Applicable standards (EMS) EN61000-6-2
EN61000-6-1
* The length of the communication and power cables should be
less than 30 m.
* To make the N-UP conform to the CE marking, attach the
ferrite core to the USB cable as shown in the following diagram.
Recommended types Model:ZCAT2035-0930 (TDK)
OP-31973 (Keyence)
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.).
Note
Provides additional information on proper operation.
TIPS
Indicates useful information or information that aids understanding of text descriptions.

For Safely Using the Product

CAUTION
Do not use the N-UB in an environment subject to flammable, explosive, or corrosive gases.
Be sure that all screws are tightened securely.
Use crimp contacts of the specified size for wiring.
The N-UB uses a 24 VDC power supply. Using a power
supply outside this range or an AC power supply may cause product failure.
Do not disassemble or modify the N-UB.This may cause product failure.
96M00272
CAUTION
Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
The N-UB is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
Be sure to observe all warnings, cautions, and precautions specified in the manual.

Foreign Regulations and Standards

Package Contents List

1
EN-UB-IM
Dedicated Communication Unit USB Output Type
Instruction Manual

General precautions

At startup and during operation, be sure to check that the
functions and performance of the N-UB is operating properly.
We recommend that you take substantial safety measures to
avoid any damage in the event a problem occurs.
If the N-UB is used in any way other than described in the
specifications or if modified, its functions and performance cannot be guaranteed.
When the N-UB is used in combination with other instruments,
functions and performance may be degraded, depending on the operating conditions and the surrounding environment.
Do not use the N-UB for the purpose of protecting the human
body.
The information contained in this manual is subject to change
without notice.

Notice

When the product is used under the circumstances or environment below, adhere to the limitations of the ratings and functions, take countermeasures for safety precautions such as fail-safe installations and consult a KEYENCE sales representative.
For useunder circumstances or environmentswhich are not
described in the manual
For usewith nuclear power control, railway, aircraft, vehicles,
incinerators, medical equipment, entertainment equipment, safety devices etc.
For use for applications where death or serious property damage
is possible and extensive safety precautions are required

For properly using the product

Do not install the N-UB in the following locations:
Locations subject to direct sunlight
Locations where the ambient temperature is outside the range of
0to +50°C or locations subject to condensation as the result of severe changes in temperature
Locations where the ambient humidity is outside the range of 35
to85%RH.
Locations subject to corrosive or flammable gases
Locations subject to dust, salts, iron dust, or oil smoke
Locations subject to shock or vibration
Locations subject to exposure of water, oil, or chemicals
Locations where strong magnetic or electric fields are generated
UL approval
The N-UB conforms to the following UL/CSA standards and has obtained the UL/C-UL approval.
Conforming standardUL508, UL60950-1
UL File No. E207185, E167973
UL categoryNRAQ/NRAQ7, NWGQ2/NWGQ8
When using the N-UB as a UL approved product, be sure to observe the following installation and environment conditions.
Pollution degree 2
Overvoltage category I

FCC regulations

The N-UB conforms to the following FCC EMI regulations.
Conforming regulationsFCC Part 15 Subpart B, Class B
digital equipment
Canada IC (Industry Canada regulations)
TheN-UB conforms to the following IC EMI regulations.
Conforming regulationsICES-003, Class B Digital equipment

CE marking

The N-UB conforms to the following essential requirements of the EU directive.
EMC directive (2004/108/EC)
By checking the conformity to the following EN standards, the conformity to the essential requirements of the EMC directive is checked and the CE marking is indicated.
Conforming standards (EMI)EN55011, Class A
EN55022, Class B
Conforming standards (EMS)EN61000-6-2
EN61000-6-1
*The length of the communication and power cables shouldbe less than 30 m. *To make the N-UP conform to the CE marking, attach the ferrite core to the USB cable as shown in the following diagram.
Recommended types Model:ZCAT2035-0930 (TDK) OP-31973 (Keyence)
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.).
Note
Provides additional information on proper operation.
TIPS
Indicates useful information or information that aids understanding of text descriptions.
For Safely Using the Product
CAUTION
Do not use the N-UB in an environment subject to flammable, explosive, or corrosive gases.
Be sure that all screws are tightened securely.
Use crimp contacts of the specified size for wiring.
The N-UB uses a 24 VDC power supply. Using a power
supply outside this range or an AC power supply may cause product failure.
Do not disassemble or modify the N-UB.This may cause product failure.
96M00272
CAUTION
Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
The N-UB is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
Be sure to observe all warnings, cautions, and precautions specified in the manual.
Foreign Regulations and Standards
Package Contents List
Main unit Instruction manual
Main unit Instruction manual
USB Output Type
N-UB
Instruction Manual
Do not install the N-UB in the following locations:
Locations subject to direct sunlight
Locations where the surrounding air temperature is outside the
range of 0 to +50°C or locations subject to condensation as the result of severe changes in temperature
Locations where the ambient humidity is outside the range of 35
to 85%RH.
Locations subject to corrosive or flammable gases
Locations subject to dust, salts, iron dust, or oil smoke
Locations subject to shock or vibration
Locations subject to exposure of water, oil, or chemicals
Locations where strong magnetic or electric fields are generated
Foreign Regulations and Standards
Failure to follow these instructions may lead to death or serious injury.
Failure to follow these instructions may lead to injury.
Failure to follow these instructions may lead to product damage (product malfunction, etc.).
Provides additional information on proper operation.
Indicates useful information or information that aids understanding of text descriptions.
For Safely Using the Product
General precautions
At startup and during operation, be sure to check that the
We recommend that you take substantial safety measures to
avoid any damage in the event a problem occurs.
If the N-UB is modified or used in any way other than described in
the specifications, its function and performance cannot be guaranteed.
When the N-UB is used in combination with other instruments, the
function and performance may be effected by operating conditions and the surrounding environment.
Do not use the N-UB for the purpose of protecting the human
body.
The information contained in this manual is subject to change
without notice.
Notice
When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
For use under circumstances or environments which are not
described in the manual
For use with nuclear power control, railway, aircraft, vehicles,
incinerators, medical equipment, entertainment equipment, safety devices etc.
For use in applications where death or serious property damage is
possible and extensive safety precautions are required.
UL certification
The N-UB complies with the following UL/CSA standards and has obtained the UL/C-UL certification.
Applicable standard UL508, UL60950-1
UL File No. E207185, E167973
UL category NRAQ/NRAQ7, NWGQ2/NWGQ8
Be sure to observe the following installation and environment conditions.
Pollution degree 2
Overvoltage category I
Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max.
Attention - Ne raccordez pas l'unité directement au circuit de dérivation. Ce produit doit être alimenté par un transformateur adapté, isolé et approuvé ou une alimentation ne dépassant pas 200 VA.
FCC regulations
The N-UB complies with the following FCC EMI regulations.
FCC Part 15 Subpart B, Class B digital device
Canada IC (Industry Canada) regulations
The N-UB complies with the following IC EMI regulations.
ICES-003, Class B digital apparatus
CE marking
The N-UB complies with the following essential requirements of the EU Directive.
EMC Directive (2004/108/EC)
The following harmonized standards are applied to this product in order to confirm the compliance.
Applicable standards (EMI) EN55011, Class A
EN55022, Class B
Applicable standards (EMS) EN61000-6-2
EN61000-6-1
* The length of the communication and power cables should be
less than 30 m.
* To make the N-UP conform to the CE marking, attach the
ferrite core to the USB cable as shown in the following diagram.
Recommended types Model: ZCAT2035-0930 (TDK)
OP-31973 (Keyence)
Package Contents List
For properly using the product
Do not use the N-UB in an environment subject to flammable, explosive, or corrosive gases.
Be sure that all screws are tightened securely.
Use crimp contacts of the specified size for wiring.
The N-UB uses a 24 VDC power supply. Using a power
supply outside this range or an AC power supply may cause product failure.
Do not disassemble or modify the N-UB.This may cause product failure.
Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
The N-UB is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
Be sure to observe all warnings, cautions, and precautions specified in the manual.
1
E N-UB-IM

Part Names and Functions

CAUTION
1. Head port
2. Power LED
3. Communication status LED
4.
USB port
5. I/O status LED
6. I/O terminals
7. Power terminal
8. DIN rail mounting tab
KV-B1
6XC
Head port
USB port
OUT1 to 4IN1
Head
BL Series SR Series
Personal computer
PLC
Timing sensor
37485
12
9
1112
6
10
Round 12-pin jack
CAUTION
Note
Power supply
24V+10%
-
20%
Twist pair cable
I/O terminal block
Circuit diagram
IN1, IN2
INCOM
Internal
circuit

Connecting the power supply

Connect the 24 VDC power supply to the power terminal of the N-UB.
Number Name Function
1 Head port Used to connect the head.
2 Power LED Lights when the power is ON.
Communication status
3
4 USB port Used to connect to the personal computer.
5 I/O status LED Monitors the ON/OFF status of I/O terminals.
6 I/O terminals
7 Power terminal Terminal for 24V DC power supply input.
8
LED
DIN rail mounting tab
Monitors the status of communication with the head.
Used to connect I/O signal lines of control units.
A tab for mounting the DIN rail.

System Configuration Figure

Using a power supply other than 24 VDC may cause product failure.
The dimensions of crimp contacts used for wiring should be as follows:
Terminal Dimensions
Round Terminal a: 6 mm Max.
Y terminal a: 6 mm Max.
Item Description
Wire size AWG14-22 Tightening torque 0.49 N·m (4.34 lbf·in) Wire material Copper Wire type Stranded wire Electric wire temperature rating
+60°C max.

Layout and wiring of the I/O terminal block

Layout of the I/O terminal block

Connection and Wiring Methods

Connecting the code reader

Connect the code reader to the head port of the N-UB.
Pin layout of the head port
Pin
Name Signal name
1 OUT1 OUT1 input Input
2 OUT2 OUT2 input Input
3 RXD RS-232C Receive Input
4 RTS RS-232C Receivable Output
5 OUT4 OUT4 input Input
6 IN2 IN2 output Output
7 TXD RS-232C Transmit Output
8 CTS RS-232C Transmittable Input
9 OUT3 OUT3 input Input
10 IN1 IN1 output Output
11 +5V +5V power supply Output
12 GND(SG) Common GND
E N-UB-IM
number
Install and remove connection cables with the power disconnected.
Signal
direction
-
Symbol Description
INCOM Common for IN terminal
IN1
Used as an input terminal for the code reader. Input
IN2
OUTCOM Common for OUT terminal
OUT1
OUT2
OUT3
OUT4
Used as an output terminal from the code reader. Output
For connection, use stranded copper wire having a
gage of AWG16 to 26 and temperature rating of 60°C or higher.
The tightening torque is 0.19 N·m (1.7 lbf·in).
Wiring IN1 and IN2
2
Signal
direction
-
-
Wiring OUT1 to 4
CAUTION
Note
OUT1 to 4
OUT COM
Load
Circuit diagram
Load
Load Load Load
Internal circuit
To the USB port of the personal computer
USB cable
Top
Bottom
80 mm or more from the front
80 mm
50 mm
50 mm
Mounting tab
DIN rail
Protrusion
DIN rail
Protrusion
Mounting tab
1. Hook
2. Push
Installing the N-UB to the DIN rail
Mounting tab
Lower with a screw driver or another tool.
A B

Wiring the USB port

Connect the USB port of the N-UB to the USB port of the personal computer. Connect the Type B connector of the USB cable to the N-UB port.
The length of the USB cable must be 5 m or less.

Installing and removing the N-UB to and from the DIN rail

Installing the N-UB to the DIN rail
1 Lower the mounting tab on the back of the N-UB.
Check that the mounting tab is placed in the position shown in the following diagram.
2 Install the N-UB to the DIN rail as shown in the following
diagram.
Users must install the USB Driver to communicate with the N-UB through a PC.

Installing the N-UB

Surrounding space

Install the N-UB vertically.
When the installation direction changes, provide adequate surrounding space so that heat does not build up.
For ventilation, maintain a space of 50mm
or more from the top and bottom of the N­UB. As long as the N-UB is the only source of heat generation, the N-UB can be installed without space on the right and left sides. Provide a space of 80 mm or more in front of the N-UB to connect the BL head.
50 mm or more on the top and bottom; no space is required on the right and left sides
Removing the N-UB from the DIN rail
1 Lower the mounting tab as shown in B in the following
diagram, and then remove the N-UB.

Installation precautions

When installing the N-UB, do not block the ventilation slots on the
top and bottom of the unit. Otherwise, heat builds up inside the unit, causing product failure.
If the temperature on the N-UB will foreseeable exceed the upper
limit of the operating temperature (50°C), take appropriate measures such as performing forced air cooling or ensuring proper ventilation so that the temperature does not exceed the upper limit of the normal operating temperature (50°C).
2 After the N-UB is removed, return the mounting tab to the
state shown in A.
3
E N-UB-IM
Copyright (c) 2015 KEYENCE CORPORATION. All rights reserved.
13453E 1015-1 96M13453 Printed in Japan

Specifications

R40
44.2
41.8
40.3
35.8
49.9
(128.5)
133.8
57

General specifications

Model N-UB
Power supply for the code reader
Display
Operating surrounding air temperature
Storage ambient temperature
Operating ambient humidity
9 LEDs (power supply status, data transmission/
5 VDC ± 5% (650 mA)
reception status, I/O terminal status)
0 to 50°C
-20 to 60°C
35 to 85%RH (no condensation)
Operating atmosphere No dust or corrosive gases present
Environment resistance
Vibration resistance
10 to 55 Hz, complex amplitude 1.5 mm, 2 hours in each of X, Y, and Z directions
Power voltage 24 VDC (+10%, -20%)
Consumption current 380 mA or less
Rating
Mass Approx. 155 g

I/O specifications

Number of pins 2 (IN1 and IN2)
Input format Bidirectional voltage input
Input
Input maximum rating 26.4 VDC
Minimum ON voltage 15 VDC
Terminal block
Output
Maximum OFF current 1 mA
Number of pins
Output format Photo MOS relay output
Output rating load 30 VDC, 100 mA
OFF time leak current 0.1 mA or less
ON time residual voltage

Communication specifications

Connector 1 (12-pin round connector)
Head interface
Host interface
Communication standards
Communication rate
Data bit length 7/8 bits
Parity check None/even/odd
Stop bit length 1/2 bits
Flow control Hardware flow control (mandatory)
Connector 1 (USB - Type B)
Communication standards
Total extended length 5 m or less
RS-232C compliant
4800, 9600, 19200, 38400,
57600, 115200 bit/s
USB 2.0 (Full-speed 12 Mbps)
4 OUT1
1 V or less
to 4

Dimensions diagram

Warranties and Disclaimers

(1) KEYENCE warrants the Products to be free of defects in materials and wor kmanship for
a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are
only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be
used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/ Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED
WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage
limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples.
E 1101-3
E N-UB-IM
4
Loading...