Instructions - Parts List
GTP10 Pump |
EN |
|
311304H |
For pumping gasoline, diesel fuel, and kerosene. Do not use to pump other fluids including water.
Models 260000 through 260017, 260019, 260024, 260580, and 260581 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor)
Models 260020 and 260021, 10 gpm (38 lpm), 24 VDC Models 260022 and 260023, 12 gpm (45 lpm), 230 VAC Models 260025 through 260028
12 gpm (45 lpm), 115 VAC (CSA C/US listed motor)
10 psi (0.07 MPa, 0.7 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
CSA mark applies only to 12 VDC and 115 VAC motors for Class I, Div I, Group D Hazardous Locations
Models
Part No. |
Hose |
|
Nozzle |
|
|
|
|
|
|
||
12 VDC, 10 gpm (38 lpm), 12.5 amps |
|
|
|||
|
|
|
|
|
|
260000 |
260069 |
- 12 ft (3.66 m) grounded |
260079 |
- manual, leaded/diesel |
|
|
|
|
|
|
|
260001 |
260069 |
- 12 ft (3.66 m) grounded |
260082 |
- automatic, regular/diesel |
|
|
|
|
|
|
|
260002 |
260069 |
- 12 ft (3.66 m) grounded |
260078 |
- manual, unleaded |
|
|
|
|
|
|
|
260003 |
260069 |
- 12 ft (3.66 m) grounded |
260083 |
- automatic, unleaded |
|
|
|
|
|
|
|
260004 |
260526 |
- 4 ft (1.22 m) UL listed assembly |
260078 - manual, unleaded |
||
260523 |
- 8 ft (2.44 m) UL listed assembly |
||||
|
|
|
|||
260005 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260006 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260007 |
260524 |
- 6 ft (1.83 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260008 |
260524 |
- 6 ft (1.83 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260009 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260010 |
260522 |
- 10 ft (3.05 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260011 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260012 |
260523 |
- 8 ft (2.44 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260013 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260014 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
||
260015 |
260523 |
- 8 ft (2.44 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
|
|
260016 |
270521 |
- 12 ft (3.66 m) UL listed assembly |
260078 - manual, unleaded |
||
260525 |
- 5 ft (1.52 m) UL listed assembly |
||||
|
|
|
|||
260017 |
260525 |
- 5 ft (1.52 m) UL listed assembly |
260078 - manual, unleaded |
||
|
|
|
|
|
|
260019 |
None |
|
None |
|
|
|
|
|
|
|
|
260024 |
None |
|
None |
|
|
|
|
|
|
|
|
260580 |
260573 |
- 12 ft (3.66 m) grounded |
260079 |
- manual, leaded/diesel |
|
|
|
|
|
|
|
260581 |
260573 |
- 12 ft (3.66 m) grounded |
260082 |
- automatic, regular/diesel |
|
|
|
|
|
||
24 VDC, 10 gpm (38 lpm), 7 amps |
|
|
|||
|
|
|
|
|
|
260020 |
260069 |
- 12 ft (3.66 m) grounded |
260079 |
- manual, leaded/diesel |
|
|
|
|
|
|
|
260021 |
260069 |
- 12 ft (3.66 m) grounded |
260082 |
- automatic, regular/diesel |
|
|
|
|
|
||
230 VAC, 12 gpm (45 lpm), 1 amps |
|
|
|||
|
|
|
|
|
|
260022 |
260069 |
- 12 ft (3.66 m) grounded |
260078 |
- manual, unleaded |
|
|
|
|
|
|
|
260023 |
260069 |
- 12 ft (3.66 m) grounded |
260083 |
- automatic, unleaded |
|
|
|
|
|
||
115 VAC, 12 gpm (45 lpm), 2 amps |
|
|
|||
|
|
|
|
|
|
260025 |
260069 |
- 12 ft (3.66 m) grounded |
260079 |
- manual, leaded/diesel |
|
|
|
|
|
|
|
260026 |
260069 |
- 12 ft (3.66 m) grounded |
260082 |
- automatic, regular/diesel |
|
|
|
|
|
|
|
260027 |
260069 |
- 12 ft (3.66 m) grounded |
260078 |
- manual, unleaded |
|
|
|
|
|
|
|
260028 |
260069 |
- 12 ft (3.66 m) grounded |
260083 |
- automatic, unleaded |
|
|
|
|
|
|
2 |
311304H |
Models
311304H |
3 |
Warnings
The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Additional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual, refer back to these pages for a description of the specific hazard.
WARNING
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources, such as cigarettes and portable electric lamps.
•Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
•Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
•Ground all equipment in the work area.
•Use only grounded hoses.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
•Keep a fire extinguisher in the work area.
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
•Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment.
•Connect only to grounded power source.
•All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
•Protective eyewear
•Clothing and respirator as recommended by the fluid and solvent manufacturer
•Gloves
•Hearing protection
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.
•Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning, checking, or servicing equipment.
•Tighten all fluid connections before operating the equipment.
•Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
4 |
311304H |
Warnings
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
•Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.
•Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only.
•Do not alter or modify equipment.
•Use equipment only for its intended purpose. Call your Graco distributor for information.
•Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•Do not kink or over bend hoses or use hoses to pull equipment.
•Keep children and animals away from work area.
•Comply with all applicable safety regulations.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.
311304H |