Faber INHC29SSV Installation Manual

0 (0)

INCA HC

Installation Instructions

Use and Care Information

Instructions d'installation

Utilisez et d'entretien

Instrucciones de instalación Información de uso y cuidado

INHC29SSV

INHC35SSV

READ AND SAVE THESE INSTRUCTIONS BEFORE YOU START

INSTALLING THIS RANGEHOOD

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting.

b)Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes

Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Useproperpansize. Alwaysusecookwareappropriateforthesizeofthesurfaceelement.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

a)SMOTHERFLAMESwithaclose-fittinglid,cookiesheet,ormetaltray,thenturnofftheburner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE

AND CALL THE FIRE DEPARTMENT.

b)NEVER PICK UP A FLAMING PAN - You may be burned.

c)DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d)Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.Thefireissmallandcontainedintheareawhereitstarted.

3.Thefiredepartmentisbeingcalled.

4.Youcanfightthefirewithyourbacktoanexit.

* Based on "Kitchen Firesafety Tips" published by NFPA

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.InstallationWorkAndElectricalWiringMustBeDoneByQualifiedPerson(s)InAccordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

2.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

2

3.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

4.Ducted fans must always be vented to the outdoors.

ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST

BE SEALED.

This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop. This hood has been approved by UL at this distance from the cooktop.

This minimum clearance may be higher depending on local building codes. For gas cooktops and combination ranges, a minimum of 30" is recommended and may be required.

Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts.

MOBILEHOMEINSTALLATIONTheinstallationofthisrangehoodmustconformtotheManufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements.

VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

Thelengthoftheductworkandthenumberofelbowsshouldbekepttoaminimumtoprovideefficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts.

Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

CAUTION-Toreduceriskoffireandtoproperlyexhaustair,besuretoductairoutside–Do notventexhaustairintospaceswithinwallsorceilingsorintoattics,crawlspaces,orgarages.

! WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

3

! WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

Failure to follow electrical requirements may result in a fire.

State of California Proposition 65 Warning (US only)

WARNING

This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

For more information go to www.P65Warnings.ca.gov

4

Faber INHC29SSV Installation Manual

RANGEHOOD DIMENSIONS

INHC29SSV

REAR RANGEHOOD DIMENSIONS

INHC35SSV

5

Min. 24"

Min. 30"

6

MAIN PARTS

 

 

Components

Ref.

Qty.

Product Components

1

1

Hood Body, complete with: Con-

 

 

trols, Light, Filters, Blower.

2

1

Power cord

6

2

Caps

8

1

Recirculation Vent Grill

10

1

Damper ø 5 7/8"

Ref.

Qty.

Installation Components

12e

2

Screws 1/8" x 3/8"

 

 

(for Recirculation Grill mounting)

 

Qty.

Documentation

 

1

Instruction Manual

H

6

Parts needed

- 6" Round Metal ductwork .

Available Accessories

Direct Connect Wiring Box sku # WIREBOX

Liner 30" Stainless #LINE30ST (Use only with INHC29SSV)

Liner 36" Stainless #LINE36ST (Use only with INHC29SSV)

Activated Charcoal Filter sku #; FILTER1

Long Lasting Activated Charcoal Filter sku# FILTER1LL

Remote Control Accessory - REMCTRL2

7

Only for Ducted Venting Installation

Install Damper that is included with the Hood before connecting to the ductwork.

Choose your ducting method

Ducted Venting Installation

Non Ducted - Recirculation

Vertical

 

6"

 

 

Requires

Horizontal

purchase of

 

Activated

 

Charcoal

 

Accessory

8

Installation Instructions

1

Hood

29"

35"

X

27 5/8"

33 3/4"

Y

13 9/16"

13 9/16"

 

 

 

´ 0LQ

X

2

 

Cut out

 

the open-

 

ing in the

 

underside

 

of the

 

cabinet as

Y

shown in

Figure 1.

 

Remove the filters from the

Insert Hood before installing into cabinet.

3.a

Ducted (in front of Vertical)

Install Roof or Wall Cap purchased separately. Connect the 6" metal ductwork to the Roof or Wall Cap and then attach ductwork.

9

3.b

Rear Ducting Installation

 

2 1/2

>

For horizontal(rear) ducting there must be a minimum of 2 1/2" of space open between the back of the Hood Insert and the wall.

[

[

For a horizontal ducting installation the motor needs to be unsecured by first removing the 12 screws as shown.

Once the screws are removed, extract the blower from the body of the Insert Hood and position it so the transition opening is facing to the rear wall (from the back remove and rotate 180 degrees to the left, and then flip it back 90 degrees as shown in the diagram).

Once the blower is in place re-install the 12 screws to fasten the motor to the Insert Hood body.

10

4

Non-Ducted Recirculation Option

 

 

For Non-Ducted Recirculation venting route the ductwork

 

to a location above the hood where the discharge is vented

 

back into the room.

Use the included Recirculation Vent Grill to cover the opening. Secure the grill with the 2 screws provided in the Install Kit.

 

 

´

Required Activated Charcoal Filter Accessory - sku # - FILTER1 (purchased separately).

Long Lasting Activated Charcoal Filter Accessory - sku # FILTER1LL (purchased separately).

5

2

Min. 24" Min. 30"

2

Install the Insert Hood through the cabinet cutout into the cabinet opening that has a minimum height of 16 ". Allow for ducting.

The range hood is secured to the cabinet cutout by two spring loaded brackets, one on each side of the range hood.

It is recommend that the Insert Hood is supported with a 3/4" wood base to insure proper alignment of the two side clips

After the Insert Hood is installed into the cabinet opening lock it into position by tightening the indicated screws in each of the two side clips from underneath the Insert Hood.

11

6

ELECTRICAL INSTALLATION WITH CONNECTION CABLE

 

GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

WARNING - Improper grounding can result in a risk of electric shock.

Consultaqualifiedelectricianifthegroundinginstructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

Max. 33 7/16

ELECTRICAL INSTALLATION WITH

OPTIONALWIRING BOX

For permanent wiring, use only the Direct Connect Wiring Box accessory sku WIREBOX, manufactured by Faber.

Direct Connect Wiring Box Accessory sku # WIREBOX (purchased separately)

7

For Non-Ducted Recirculation

8

 

 

Option

 

Attach each

 

 

charcoal

 

 

filter to the

 

 

black grid on

 

 

each side of

 

 

the blower.

 

 

Press the

 

 

charcoal

 

 

filter tightly

 

 

to the black

 

 

grid on the

 

 

blower side

1

 

and rotate

 

 

the filter

 

 

clockwise (towards the front of the insert hood)

 

until it locks into place. Turn counterclockwise

 

(towards the back of the insert hood) to remove.

 

Required Activated Charcoal Filter Accessory - sku # - FILTER1

Long Lasting Activated Charcoal Filter Accessory - sku # FILTER1LL (purchased separately)

Replace the grease filters removed previously.

12

9

Insert the 2 Caps in the screws hole, as shown.

LINER DIMENSIONS

Standard Liner 30 Stainless (LINE30ST)

0"

Standard Liner 36 Stainless (LINE36ST)

"Note: Standard Liners need to have the center perforation removed for installation"

ADDITIONALFIXATION POINTS

3/16 “

Max.1 3/4

Min.1 3/8

"Note: Possible additional fixation points of the product with 4 screws "

13

FOR INSTALLATION WITH LINERS

! WARNING

When building a custom hood, always follow all applicable codes and standards.

The Inca HC can be used with

 

 

 

custom cabinetry and hoods 30"

 

 

 

wide and up. Choose either a

 

 

 

custom liner or our Standard Liner

 

 

 

designed for 30" and 36" wide

CUSTOM/WOOD

installations.

HOOD

Liners create a perfectly-sealed,

 

 

 

non-combustible finish for the

 

 

 

underside of your custom/wood

 

 

 

 

 

 

hood.

 

 

 

The Standard Liners are made up of two sections: a larger, rear section (pre-cut out for insertion of

the Inca Smart) and a front section for a total adjustable depth between 16" and 17 7/8".

!!! IMPORTANT NOTE: YOU MUST REMOVE THE ADDITIONAL PERFORATED SECTION AROUND THE PRE-CUT-

OUT WHEN INSTALLING THE STANDARD LINER WITH THE INCA HC SS MODEL.

Consider the shape, size, and weight of the Inca HC and Liner to determine the configuration of the custom/wood hood.

STANDARD LINER

INCA HC SS

1.The custom/wood hood must have a sturdy base (3/4" plywood recommended) to accomodate the cutout for the Inca HC. The base must be recessed to accomodate the height of the Liner (see LINER DIMENSIONS on Page 13). The Liner attaches to the

bottom of the base using screws appropriate for the size and material of your custom/ wood hood. The Inca HC inserts into the cut-out in the Liner and base.

2.Position the rear section of the Liner so that it abuts the back edge of your custom/ wood hood. Using a pen, trace the outline of the pre-cut out. Remove the Liner and proceed to MAKE YOUR CUT-OUTS. Install both sections of the Liner and proceed to INSTALL THE Range hood.

14

USE AND CARE INFORMATION

For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the rangehood to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

T2

T3

T4

L

T1. Fan off button:turn the blower Off. The fan can be operated by pressing any of the fan setting buttons. Hold down this button for 2 seconds to activate Delay off function which will keep the fan on for 15 minutes and automatically shut off.

T2. Fan settings buttons: Low speed.

T3. Fan settings buttons: Medium speed.

T4. Fan settings buttons: High speed / Intensive speed.

Hold down the button for 2 seconds to activate the intensive speed, which is timed to run for 6 minutes. At the end of this time it will automatically return to the speed set before.Suitable to deal with maximum levels of cooking fumes.

L. Light button: On/Off switch for the lights.

NOTE: If your product has had a CFM adjustment, refer to the CFM adjustment manual for the information. Some motor speeds or functions may be reduced.

15

Cleaning metal grease filters

The metal grease filters can be cleaned in hot detergent solution or washed in the dishwasher. They should be cleaned every 2 months, or more frequently if use is particularly heavy.

Remove the filter, pushing the lever towards the back of the unit and at the same time pulling downward.

Wash the filter without bending it, leave it to dry thoroughly before replacing (if the surface of the filter changes color overtime,thiswillhaveabsolutelynoeffectonitsefficiency).

Replace, taking care to ensure that the handle faces forward.

Cleaning in dishwasher may dull the finish of the metal grease filter.

No water can be present in filters before installing back in hood.

Replacing Activated Charcoal Filter

TheActivated Charcoal Filters are not washable and cannot be regenerated, and should be replaced approximately every 4 months of operation, or more frequently with heavy usage.

Removethecharcoalfilterbyrotatingitclockwise(backwards)until it unlocks from the motor housing and pull off sideways.

To re-insert each charcoal filter, place up against the side of the blower and push it inward. Then turn the charcoal filter clockwise (forward) until it fits into place.

Caution: "When used in recirculation mode, to Reduce the Risk of Fire and Shock use only conversion kit Model FILTER 1 or FILTER1LL"

A

B

Lighting unit

Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder.

a a

b

b

Gu10 self-ballasted led lamps

– listed in accordance with ul

1993/nmx-j-578/1-ance/csa c22.2 No. 1993

16

 

 

 

 

 

 

Wiring Diagram

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

Loading...
+ 39 hidden pages