FAAC XR2 433-868C User Manual

0 (0)
FAAC XR2 433-868C User Manual

XR2 433 C - XR2 868 C

1 DESCRIPTION

The XR2 C control board is a two-channel external receiver, which has an integrated decoding system (DS, SLH, LC), named OMNIDEC. When a channel is activated by radio control (DS, SLH, LC), the relevant N.O. relay contact closes by the methods described in chapter 5.

The selectable configurations are:

CH1 = pulsed N.O. relay output

CH2 = pulsed/fixed N.O relay output (selectable by DS1)

32,5

70

 

3

2

90

 

98

105

1 4

a Preperforated facility for cable grippers b Cover

c Facility for securing on DIN guide d Fittings for screw securing

e Terminals for command output (N.O.) f Normally open (N.O.) relay contact g Signalling LEDs (ON= OUTPUT ACTIVE)

DL1=LED CH 1

DL2=LED CH2

h Radio programming push-buttons

SW1=PUSH-BUTTON CH1

SW2=PUSH-BUTTON CH2

i DS1: Selection dip-switch j Power supply terminal k Terminal for antenna

l DL3: Mains ON LED ( ON = MAINS PRESENT )

2 TECHNICAL SPECIFICATIONS

DS

ON

OFF

 

 

 

DIP

OUTPUT

OUTPUT

SWITCH

CHANNEL 2

CHANNEL 2

 

FIXED

PULSED

 

 

 

DIP

 

 

SWITCH 2

NOT USED

NOT USED

 

 

 

DL3

9

2 12

11

DS

DL

DL2

7

 

 

SW

SW2

8

 

N.O.

N.O.

6

 

 

10

5

 

+ CH1 CH2

Fig.1

 

XR2 433 C

XR2 868 C

POWER SUPPLY (V)

12/24 ac-dc

12/24 ac-dc

RECEPTION FREQUENCY (MHz)

433.92 ±0.1

868.35±0.2

 

 

 

ABSORBED CURRENT (A)

100 mA

100 mA

 

 

 

DECODING (OMNIDEC SYSTEM)

DS-LC-SLH

DS-SLH

 

 

 

SAVEABLE CODES

250

250

NUMBER OF CHANNELS

2

2

NUMBER OF RELAY OUTPUTS (N.O.)

N 1 pulsed (CH1)

N 1 pulsed (CH1)

 

N 1 pulsed/fixed (selectable) (CH2)

N 1 pulsed/fixed (selectable) (CH2)

 

 

 

RELAY CONTACTS CAPACITY

0.5 A / 120 VA

0.5 A / 120 VA

 

 

 

PROTECTION CLASS

IP 44

IP 44

 

 

 

OPERATING AMBIENT TEMPERATURE (°C)

-20 / +55

-20 / +55

ENGLISH