DYNEX DSF45425, DSF45424, DSF45422, DSF45420 Datasheet

0 (0)

DFS454

DFS454

Fast Recovery Diode

Replaces March 1998 version, DS4145-3.4

DS4145-4.0 January 2000

APPLICATIONS

Induction Heating

A.C. Motor Drives

Inverters And Choppers

Welding

High Frequency Rectification

UPS

FEATURES

Double Side Cooling

High Surge Capability

Low Recovery Charge

VOLTAGE RATINGS

Type Number

Repetitive Peak

Conditions

 

Reverse Voltage

 

 

VRRM

 

 

V

 

 

 

 

DFS454 25

2500

VRSM = VRRM + 100V

DFS454 24

2400

 

DFS454 22

2200

 

DFS454 20

2000

 

 

 

 

KEY PARAMETERS

 

 

 

 

 

 

 

 

VRRM

 

2500V

 

 

 

 

 

 

 

 

IF(AV)

 

365A

 

 

 

 

 

 

 

 

IFSM

 

3500A

 

 

 

 

 

 

 

 

Qr

 

200μC

 

 

 

 

 

 

 

 

trr

 

2.0μs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outline type code: M771.

See Package Detials for further information.

CURRENT RATINGS

Symbol

Parameter

 

 

Conditions

Max.

Units

 

 

 

 

 

 

 

 

 

Double Side Cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Mean forward current

Half wave resistive load, T

case

= 65oC

365

A

F(AV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

RMS value

T

case

= 65oC

 

 

575

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

525

A

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Side Cooled (Anode side)

 

 

 

 

 

 

 

 

 

 

 

 

IF(AV)

Mean forward current

Half wave resistive load, Tcase = 65oC

242

A

I

RMS value

T

case

= 65oC

 

 

380

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

335

A

F

 

 

 

 

 

 

 

1/8

DFS454

SURGE RATINGS

Symbol

Parameter

Conditions

 

 

Max.

Units

 

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 0% VRRM, Tj = 150oC

3.5

kA

I2t

I2t for fusing

61 x 103

A2s

 

 

 

 

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 50% VRRM, Tj = 150oC

2.8

kA

I2t

I2t for fusing

39.2 x 103

A2s

 

 

 

 

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 100% V

T

= 150oC

-

kA

 

 

 

 

I2t

I2t for fusing

RRM,

j

 

-

A2s

 

 

 

 

 

 

 

 

 

 

THERMAL AND MECHANICAL DATA

Symbol

Parameter

Conditions

 

Min.

Max.

Units

 

 

 

 

 

 

 

 

 

Double side cooled

dc

-

0.07

oC/W

 

 

 

 

 

 

 

R

Thermal resistance - junction to case

 

Anode dc

-

0.133

oC/W

th(j-c)

 

Single side cooled

 

 

 

 

 

 

 

 

 

 

 

 

Cathode dc

-

0.147

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Clamping force 3.5kN

Double side

-

0.02

oC/W

Rth(c-h)

Thermal resistance - case to heatsink

 

 

 

 

with mounting compound

Single side

-

0.04

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Tvj

Virtual junction temperature

On-state (conducting)

 

-

150

oC

Tstg

Storage temperature range

 

 

-55

175

oC

-

Clamping force

 

 

3.0

4.0

kN

 

 

 

 

 

 

 

CHARACTERISTICS

Symbol

Parameter

 

 

Conditions

Typ.

Max.

Units

 

 

 

 

 

 

VFM

Forward voltage

At 1000A peak, Tcase = 25oC

-

3.1

V

I

RRM

Peak reverse current

At V

RRM

, T = 150oC

-

50

mA

 

 

 

case

 

 

 

 

 

 

 

 

 

 

 

 

 

trr

Reverse recovery time

 

 

 

2.0

-

μs

QRA1

Recovered charge (50% chord)

IF = 750A, diRR/dt = 100A/μs

-

200

μC

IRM

Reverse recovery current

Tcase = 125oC, VR = 100V

150

-

A

 

K

Soft factor

 

 

 

1.3

-

-

 

 

 

 

 

 

VTO

Threshold voltage

At Tvj = 150oC

-

1.64

V

 

rT

Slope resistance

At Tvj = 150oC

-

1.54

mΩ

 

 

 

 

 

 

 

V

FRM

Forward recovery voltage

di/dt = 1000A/μs, T = 125oC

-

120

V

 

 

 

 

 

j

 

 

 

 

 

 

 

 

 

 

 

 

 

2/8

DYNEX DSF45425, DSF45424, DSF45422, DSF45420 Datasheet

DFS454

DEFINITION OF K FACTOR AND QRA1

QRA1 = 0.5x IRR(t1 + t2)

dIR/dt

k = t

1

/t

t1

t2

2

 

τ

 

 

 

0.5x IRR

 

 

 

IRR

 

 

 

CURVES

F

Instantaneous forward current I - (A)

2000 Measured under pulse

conditions

1750

1500

1250

Tj = 150˚C

1000

Tj = 25˚C

750

500

 

 

 

 

1.0

2.0

3.0

4.0

5.0

Instantaneous forward voltage VF - (V)

Fig. 1 Maximum (limit) forward characteristics