DYNEX DF05125, DF05124, DF05122, DF05120 Datasheet

0 (0)

DF051

DF051

Fast Recovery Diode

Replaces March 1998 version, DS4147-4.3

DS4147-5.0 January 2000

APPLICATIONS

Induction Heating

A.C. Motor Drives

Inverters And Choppers

Welding

High Frequency Rectification

UPS

FEATURES

Double side cooling

High surge capability

Low recovery charge

VOLTAGE RATINGS

Type Number

Repetitive Peak

Conditions

 

Reverse Voltage

 

 

VRRM

 

 

V

 

 

 

 

DF051 25

2500

VRSM = VRRM + 100V

DF051 24

2400

 

DF051 22

2200

 

DF051 20

2000

 

 

 

 

Lower voltage grades available.

KEY PARAMETERS

 

 

 

 

 

 

 

 

 

 

VRRM

 

 

 

2500V

 

 

 

 

 

 

 

 

 

 

IF(AV)

 

 

 

1490A

 

 

 

 

 

 

 

 

 

 

IFSM

 

 

 

14000A

 

 

 

 

 

 

 

 

 

 

Qr

 

 

 

800μC

 

 

 

 

 

 

 

 

 

 

trr

 

 

 

5.0μs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outline type code: CB450.

See Package Details for further information.

CURRENT RATINGS

Symbol

Parameter

 

 

Conditions

Max.

Units

 

 

 

 

 

 

 

 

 

Double Side Cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Mean forward current

Half wave resistive load, T

case

= 65oC

1490

A

F(AV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

RMS value

T

case

= 65oC

 

 

2340

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

2160

A

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Side Cooled (Anode side)

 

 

 

 

 

 

 

 

 

 

 

 

IF(AV)

Mean forward current

Half wave resistive load, Tcase = 65oC

995

A

I

RMS value

T

case

= 65oC

 

 

1560

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

1390

A

F

 

 

 

 

 

 

 

1/7

DF051

SURGE RATINGS

Symbol

Parameter

Conditions

Max.

Units

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 0% VRRM, Tj = 150oC

14.0

kA

I2t

I2t for fusing

980 x 103

A2s

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 50% VRRM, Tj = 150oC

11.2

kA

I2t

I2t for fusing

627 x 103

A2s

 

 

 

 

 

 

THERMAL AND MECHANICAL DATA

Symbol

Parameter

Conditions

 

Min.

Max.

Units

 

 

 

 

 

 

 

 

 

Double side cooled

dc

-

0.018

oC/W

 

 

 

 

 

 

 

R

Thermal resistance - junction to case

 

Anode dc

-

0.034

oC/W

th(j-c)

 

Single side cooled

 

 

 

 

 

 

Cathode dc

-

0.038

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Clamping force 23.5kN

Double side

-

0.003

oC/W

Rth(c-h)

Thermal resistance - case to heatsink

 

 

 

 

with mounting compound

Single side

-

0.006

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Tvj

Virtual junction temperature

On-state (conducting)

 

-

150

oC

Tstg

Storage temperature range

 

 

-55

150

oC

-

Clamping force

 

 

21.0

25.0

kN

 

 

 

 

 

 

 

CHARACTERISTICS

Symbol

Parameter

 

 

Conditions

Typ.

Max.

Units

 

 

 

 

 

 

 

 

V

Forward voltage

At 1500A peak, T

case

= 25oC

-

1.85

V

 

FM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

RRM

Peak reverse current

At V

RRM

, T = 150oC

-

100

mA

 

 

 

case

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

trr

Reverse recovery time

 

 

 

 

 

5.0

-

μs

QRA1

Recovered charge (50% chord)

IF = 1000A, diRR/dt = 100A/μs

-

800

μC

IRM

Reverse recovery current

Tcase = 150oC, VR = 100V

-

250

A

 

K

Soft factor

 

 

 

 

 

1.6

-

-

 

 

 

 

 

 

 

 

VTO

Threshold voltage

At Tvj = 150oC

 

 

-

1.1

V

 

rT

Slope resistance

At Tvj = 150oC

 

 

-

0.5

mΩ

 

 

 

 

 

 

V

Forward recovery voltage

di/dt = 1000A/μs, T = 125oC

-

-

V

 

FRM

 

 

 

 

j

 

 

 

 

2/7

DYNEX DF05125, DF05124, DF05122, DF05120 Datasheet

DF051

DEFINITION OF K FACTOR AND QRA1

QRA1 = 0.5x IRR(t1 + t2)

dIR/dt

t2

k = t1/t2

t1

τ

 

 

0.5x IRR

 

 

IRR

 

 

CURVES

 

4000

 

 

 

 

3500

 

- (A)

3000

 

 

 

2500

 

F

 

 

 

current I

 

 

forward

2000

 

 

 

Instantaneous

1500

 

 

 

 

1000

 

 

500

 

 

 

 

0

Measured under pulse conditions

Tj = 25˚C

Tj = 150˚C

1.0 2.0 3.0 4.0

Instantaneous forward voltage VF - (V)

Fig.1 Maximum (limit) forward characteristics

3/7