DYNEX DF25216, DF25214, DF25212, DF25210, DF25206 Datasheet

0 (0)
DYNEX DF25216, DF25214, DF25212, DF25210, DF25206 Datasheet

DF252

DF252

Fast Recovery Diode

Replaces March 1998 version, DS4142-3.4

DS4142-4.0 January 2000

APPLICATIONS

Induction Heating

A.C. Motor Drives

Inverters And Choppers

Welding

High Frequency Rectification

UPS

FEATURES

Double Side Cooling

High Surge Capability

Low Recovery Charge

VOLTAGE RATINGS

Type Number

Repetitive Peak

Conditions

 

Reverse Voltage

 

 

VRRM

 

 

V

 

 

 

 

DF252 16

1600

VRSM = VRRM + 100V

DF252 14

1400

 

DF252 12

1200

 

DF252 10

1000

 

DF252 08

800

 

DF252 06

600

 

KEY PARAMETERS

 

 

 

 

 

 

 

 

VRRM

 

1600V

 

 

 

 

 

 

 

 

IF(AV)

 

360A

 

 

 

 

 

 

 

 

IFSM

 

3000A

 

 

 

 

 

 

 

 

Qr

 

35μC

 

 

 

 

 

 

 

 

trr

 

3.2μs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outline type code: M771.

See Package Details for further information.

CURRENT RATINGS

Symbol

Parameter

 

 

Conditions

Max.

Units

 

 

 

 

 

 

 

 

 

Double Side Cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Mean forward current

Half wave resistive load, T

case

= 65oC

360

A

F(AV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

RMS value

T

case

= 65oC

 

 

560

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

500

A

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Side Cooled (Anode side)

 

 

 

 

 

 

 

 

 

 

 

 

IF(AV)

Mean forward current

Half wave resistive load, Tcase = 65oC

276

A

I

RMS value

T

case

= 65oC

 

 

435

A

F(RMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Continuous (direct) forward current

T

case

= 65oC

 

 

375

A

F

 

 

 

 

 

 

 

1/8

DF252

SURGE RATINGS

Symbol

Parameter

Conditions

 

 

Max.

Units

 

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 0% VRRM, Tj = 150oC

3.0

kA

I2t

I2t for fusing

45 x 103

A2s

 

 

 

 

 

 

 

 

 

 

IFSM

Surge (non-repetitive) forward current

10ms half sine; with 50% V

T

= 150oC

2.4

kA

 

 

 

 

I2t

I2t for fusing

RRM,

j

 

28.8 x 103

A2s

 

 

 

 

 

 

 

 

 

 

THERMAL AND MECHANICAL DATA

Symbol

Parameter

Conditions

 

Min.

Max.

Units

 

 

 

 

 

 

 

 

 

Double side cooled

dc

-

0.07

oC/W

 

 

 

 

 

 

 

R

Thermal resistance - junction to case

 

Anode dc

-

0.133

oC/W

th(j-c)

 

Single side cooled

 

 

 

 

 

 

 

 

 

 

 

 

Cathode dc

-

0.147

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Clamping force 3.5kN

Double side

-

0.02

oC/W

Rth(c-h)

Thermal resistance - case to heatsink

 

 

 

 

with mounting compound

Single side

-

0.04

oC/W

 

 

 

 

 

 

 

 

 

 

 

 

Tvj

Virtual junction temperature

On-state (conducting)

 

-

150

oC

Tstg

Storage temperature range

 

 

-55

150

oC

-

Clamping force

 

 

3.0

4.0

kN

 

 

 

 

 

 

 

2/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DF252

CHARACTERISTICS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

Parameter

 

 

 

 

 

 

 

Conditions

Typ.

Max.

 

Units

 

 

 

 

 

 

 

 

 

 

 

V

FM

Forward voltage

At 450A peak, T

case

= 25oC

-

1.6

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

Peak reverse current

At V

 

, T

case

= 125oC

-

20

 

mA

RRM

 

 

 

RRM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

trr

Reverse recovery time

 

 

 

 

 

 

 

 

 

 

3.2

-

 

μs

QRA1

Recovered charge (50% chord)

IF = 750A, diRR/dt = 100A/μs

-

35

 

μC

I

 

Reverse recovery current

T

case

= 125oC, V

R

= 100V

-

21

 

A

RM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

Soft factor

 

 

 

 

 

 

 

 

 

 

1.5

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

TO

Threshold voltage

At T

 

= 150oC

 

 

 

 

-

1.0

 

V

 

 

 

vj

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r

T

Slope resistance

At T

 

= 150oC

 

 

 

 

-

1.33

 

mΩ

 

 

 

vj

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

Forward recovery voltage

di/dt = 1000A/μs, T = 125oC

-

50

 

V

FRM

 

 

 

 

 

 

 

 

 

 

j

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEFINITION OF K FACTOR AND QRA1

QRA1 = 0.5x IRR(t1 + t2)

dIR/dt

t2

k = t1/t2

t1

τ

 

 

0.5x IRR

 

 

IRR

 

 

3/8

Loading...
+ 5 hidden pages