AEG DM8600-M/CH Manual

0 (0)

DM 8600

Dunstabzugshaube

Hotte aspirante

Cappa aspirante

Cooker hood

Montageund Gebrauchsanweisung Notice d’utilisation et d’installation Istruzioni di montaggio e uso Operating and Installation Instructions

Contents

Safety warnings

49

for the user

49

for the installer

49

Description of the appliance

51

Extractor version

51

Filter Version

52

Control Panel

53

Maintenance and care

54

Metal grease filter

54

Open the metal grease filter

54

Charcoal filter

55

Changing the light bulb

56

Cleaning

56

Special accessories

57

Technical assistance service

57

Technic Specifications

58

Mounting accessories included

58

Electrical connection

59

Safety warnings for the electrician

59

Wall unit mounting

60

Special accessories/Vapour screen

62

48

Safety warnings

for the user

Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.

Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control.

The hot oil in the frying pan might ignite due to overheating.

The risk of self-ignition increases when the oil being used is dirty.

It is extremely important to note that overheating can cause a fire.

Never carry out any flambé cooking under the hood.

Always disconnect the unit from the power supply before carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker).

It is very important to clean the hood and replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, resulting in a fire hazard.

for the installer

When used as an extractor unit, the hood must be fitted with a 150mm diameter hose.

Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/ 125 mm reduction flange provided. In this case the hood will be slightly more noisier.

When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces:

electric cookers

600 mm

gas cookers

650 mm

coal and oil cookers

700 mm min.

The national Standard on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms.

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

49

It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct.

The air outlet installation must comply with the regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures.

When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation:

short and straight outlet hose

keep bends in outlet hose to a minimum

never install the hoses with an acute angle, they must

always follow a gentle curve only

— keep the hose as large as possible (preferably the same diameter as the outlet hole).

Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood.

50

Description of the Appliance

Extractor version

The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one charcoal filter (special accessory).

You will need original AEG charcoal filter for this function (see Special Accessories).

The air is discharged to the outside through a pipe, which must be fitted to connection flange D. Fig. 1.

In order to obtain the best performance the hose should have a diameter equal to the outlet hole.

Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/ 125 mm reduction flange provided. In this case the hood will be slightly more noisier.

D

Fig. 1

51

AEG DM8600-M/CH Manual

Filter Version

The air is filtered through a charcoal filter and returned to the kitchen through the top grill of the outlet pipe.

You will need an original AEG KF20 charcoal filter for the filtering function. (See Special Accessories).

Fix the deflector using 4 screws Ø 2,9x6.5 mm. Fig. 2.

Optionally, the position of the chimney elements can be changed. When using the hood in the filter version the chimney must be fixed at the top, with the air outlet grill at the side.

Fig. 2