Zte ZXR10 3928A, ZXR10 3928A-FI, ZXR10 3228A-FI, ZXR10 3228A, ZXR10 3252A Hardware Installation Manual

...
0 (0)
ZXR103900A/3200ASeries
IntelligentRoutingSwitch
HardwareInstallationManual
Version2.8.23.A
ZTECORPORATION ZTEPlaza,KejiRoadSouth, Hi-TechIndustrialPark, NanshanDistrict,Shenzhen, P .R.China 518057 Tel:(86)75526771900 Fax:(86)75526770801 URL:http://ensupport.zte.com.cn E-mail:support@zte.com.cn
LEGALINFORMATION
Copyright©2006ZTECORPORATION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionordistributionof thisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwrittenconsentofZTECORPO­RATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedbycontractualcondentialityobligations.
Allcompany ,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTECORPORA TION oroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditionsaredis­claimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,titleornon-in­fringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromtheuseoforrelianceonthe informationcontainedherein.
ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplicationscoveringthesubject matterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTECORPORATIONanditslicensee, theuserofthisdocumentshallnotacquireanylicensetothesubjectmatterherein.
ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.020100114
FirstRelease
SerialNumber:SJ-20100114103959-001
Contents
AboutThisManual..............................................i
SafetyIntroduction...........................................1
SafetyIntroduction.........................................................1
SafetyDescriptions.........................................................1
SystemOverview..............................................3
ProductOverview...........................................................3
Functions......................................................................4
TechnicalFeaturesandParameters...................................5
StructureandPrinciple......................................9
WorkingPrinciples..........................................................9
HardwareStructure.......................................................10
ZXR103228A............................................................10
ZXR103228A-EI.......................................................11
ZXR103228A-FI........................................................12
ZXR103252A............................................................12
ZXR103928A............................................................13
ZXR103928A-FI........................................................14
ZXR103952A............................................................14
ZXR103928A-PS.......................................................15
Units/ComponentsDescription.......................17
ControlandSwitchingBoard...........................................17
LineInterfaceCard........................................................20
FGEI........................................................................20
FGFI........................................................................21
FGFE........................................................................21
FBFE........................................................................22
PowerModule.................................................23
PowerModuleOverview..................................................23
ActivePowerSupply......................................................23
StandbyPowerSupply...................................................25
3228A-EIMonitoringInterface.........................................25
550wPowerSupplyUnitforZXR103928A-PS..................25
InstallationandDebugging.............................27
EquipmentInstallation...................................................27
DesktopInstallation...................................................27
CabinetInstallation....................................................28
CableInstallation..........................................................29
PowerCableInstallation.............................................29
ConsoleCableInstallation...........................................31
NetworkCableInstallation.........................................32
OpticalFiberInstallation.............................................33
Power-onProcedure.......................................................34
RPS180BackupPower....................................35
SystemOverview..........................................................35
ProductOverview.....................................................35
Functions................................................................35
TechnicalFeaturesandParameters..............................36
StructureandPrinciple...................................................36
WorkingPrinciples....................................................36
HardwareStructure...................................................37
Boards.........................................................................38
PowerConversionBoard.............................................38
CAPU.......................................................................38
CDPU.......................................................................38
LPDB.......................................................................39
InstallationandDebugging.............................................39
EquipmentInstallation...............................................39
DesktopInstallation..........................................39
CabinetInstallation..........................................39
CableInstallation.....................................................39
PowerCableInstallation....................................39
Power-onProcedure..........................................41
Figures............................................................43
Tables.............................................................45
PrerequisiteSkill
andKnowledge
WhatIsinThis

AboutThisManual

PurposeThismanualisZXR103900A/3200ASeries(V2.8.23.A)Intelli-
gentRoutingSwitchHardwareInstallationManual.Itprovides proceduresandguidelinesthatsupporttheoperationonZXR10 3900A/3200ASeriesIntelligentRoutingSwitches,including:
ZXR103928AIntelligentRoutingSwitch
ZXR103928A-FIIntelligentRoutingSwitch
ZXR103952AIntelligentRoutingSwitch
ZXR103228AIntelligentRoutingSwitch
ZXR103228A-FIIntelligentRoutingSwitch
ZXR103228A-EIIntelligentRoutingSwitch
ZXR103252AIntelligentRoutingSwitch
ZXR103928A-PSIntelligentRoutingSwitch
Intended Audience
Manual
Thismanualisintendedforengineersandtechnicianswhoper­formoperationactivitiesonZXR103900A/3200AIntelligentRout­ingSwitches.
Tousethehardwareinstallationmanualeffectively ,usersshould haveageneralunderstandingofOSIModel.Familiaritywiththe followingishelpful,
Protocols
RoutingconceptsandDataCommunicationT erminologies
Thehardwareinstallationmanualcontainsthefollowingchapters:
TABLE1CHAPTERSUMMARY
Chapter
Chapter1Safety Instructions
Chapter2System Overview
Chapter3Structureand Principle
Chapter4Units/Compo­nentsDescription
Chapter5PowerModuleThischapterdescribesstructureand
CondentialandProprietaryInformationofZTECORPORATIONi
Summary
Thischapterdescribesthesafety instructionsandsigns.
Thischapterdescribestheoverviewand softwareandhardwarefeaturesofZXR10 3900A/3200Asystem.
ThischapterdescribesZXR103900A/3200A structureandprinciples..
ThischapterdescribesZXR103900A/3200A units/components.
parametersofZXR103900A/3200Apower modules.
ZXR103900A/3200ASeriesHardwareInstallationManual
Chapter
Chapter6Installation andDebugging
Chapter7RPS180 BackupPower
Documentation
Related
Thefollowingdocumentationisrelatedtothismanual:
ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
Summary
ThischapterdescribesZXR103900A/3200A installationprocedureanddebugging method.
ThischapterdescribesRPS180Backup Power ,includingitsfunctions,technical featuresandparameters,workingprinciple, hardwarestructure,control&SwitchCard, lineinterfacecard,powermoduleandfans.
SwitchHardwareManual
ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(EthernetVolume)
ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(BasicCongurationVolume)
ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(IPv4Volume)
ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(IPv6Volume)
iiCondentialandProprietaryInformationofZTECORPORATION
Chapter1

SafetyIntroduction

TableofContents
SafetyIntroduction.............................................................1
SafetyDescriptions.............................................................1

SafetyIntroduction

Inordertooperatetheequipmentinaproperway,followthese instructions:
Onlyqualiedprofessionalsareallowedtoperforminstallation,
operationandmaintenanceduetothehightemperatureand highvoltageoftheequipment.
Observethelocalsafetycodesandrelevantoperationpro-
ceduresduringequipmentinstallation,operationandmainte­nancetopreventpersonalinjuryorequipmentdamage.Safety precautionsintroducedinthismanualaresupplementarytothe localsafetycodes.
ZTEbearsnoresponsibilityincaseofuniversalsafetyoper-
ationrequirementsviolationandsafetystandardsviolationin designing,manufacturingandequipmentusage.

SafetyDescriptions

ContentsdeservingspecialattentionduringZXR103900A/3200A congurationareexplainedinT able2.
TABLE2SAFETYDESCRIPTION
Conven­tion
Note
Important
Result
ExampleItprovidesinstanceillustration.
Meaning
Itprovidesadditionalinformation.
Itprovidesgreatsignicanceorconsequence.
Itprovidesconsequenceofactions.
CondentialandProprietaryInformationofZTECORPORATION1
ZXR103900A/3200ASeriesHardwareInstallationManual
Thispageisintentionallyblank.
2CondentialandProprietaryInformationofZTECORPORATION
Chapter2

SystemOverview

TableofContents
ProductOverview...............................................................3
Functions..........................................................................4
TechnicalFeaturesandParameters.......................................5

ProductOverview

ZXR103900A/3200AareindependentlydevelopedbyZTE.These productsarewidelyusedinaccesslayerandconvergencelayerin enterprisenetworkandtheysupportlayer–3application.Incon­vergencelayer,theymeetthecustomer'sdemandsonupgradeby gigstackingdevices.Inaccesslayer ,asingledevicecanmeetcus­tomer'sbasicrequirements.ZXR103900A/3200Acanalsobeused incarriernetworkservingastandemswitchandaccessswitchor otherdeviceintelecommunicationMAN.
ZXR103900A/3200Aprovides100MpbsEthernetinterfaceandgi­gabitEthernetinterfaces.AllportssupportL2/L3linespeedfor­wardingtomeetincreasingrequirementsonbandwidth.Addition­ally,ZXR103900A/3200Asupportsdiverseunicastandmulticast protocols.
Withthenetworkdevelopment,moreandmoreservicesaresup­portedondatanetworks.Thus,higherrequirementsonnetwork devicequalityandsecurityshouldbemet.ZXR103900A/3200A providesabundantpoliciesandresourcesfortheQualityofService (QoS)andACLtoensuretheQoSandsystemsecurity .
ZXR103928A-PSEthernetswitchinZXR103900A/3200Asupports PoE.Allofthe24100MpbsportsonthisswitchsupportPoEpower supply,PoEinCISCOstandardandIEEE802.3afstandard.The maximumone-portoutputis15.4w.Atthesametime,2415.4w portscanbesupported.ThisPOEswitchcanbeusedtoconnect deviceonEthernetreceivingend,includingCISCOIPtelephone, accesspointandcamera.Alldown-streamEthernetreceivingend switchcanbepoweredthroughPoEoutputport.ByusingPoE switch,youdonotneedtoinstallwalloutletorpurchaseagreat amountofcablesandcircuitsinIPtelephoneandWLANdeploy­ment.Additionally,powerconnectororPoEcrossovercablesare notrequiredforrunningIPdevices.
ZXR103900A/3200Ahasthefollowingfeatures:
Carrier-classreliability
Full-speedforwardingandlteringcapability
CondentialandProprietaryInformationofZTECORPORATION3
ZXR103900A/3200ASeriesHardwareInstallationManual
Abundantnetworkprotocols
Openarchitecturedesignwithgreaterupgradecapability

Functions

ZXR103900Acontainsthefollowingfourproducts:ZXR103928A, ZXR103928A-FI,ZXR103952A,ZXR103928A-PS.Inthesame way,ZXR103200Acontainsfourproductstoo:ZXR103228A, ZXR103228A-FI,3228A-EI,ZXR103252A.AlltheaboveEther­netswitchseriesproductsusethesamesolution.
1.PhysicalPort
Supportingportrate,duplexmodeandauto-sensing
Supportingportmirroring
Supportingbroadcaststormsuppression
Supportinglinediagnosis&analysis
2.VLAN
SupportingVLANbasedonport,protocol,andsubnet
SupportingIEEE802.1Q,allowingupto4094VLANs
SupportingPVLAN
SupportingSVLAN
SupportingSuperVLAN
3.Layer2Protocols
SupportingSTP,RSTPandMSTP
SupportingstaticTrunkandLACP
SupportingIGMPSnooping
4.RoutingProtocols
Supportingunicastroutingprotocolssuchasstaticroute,
RIPv1/v2,OSPF,IS-IS,BGP
SupportingmulticastroutingprotocolssuchasIGMPv1/v2,
PIM-SM,MSDP
5.ACL
SupportingbasicACL,extendedACL,L2ACLandhybrid
ACL
SupportingACLtimerangelimit
6.QoS
Supporting802.1p
SupportingSPandWRRqueueschedulemode
Supportingtrafcmonitoring
Supportingow-basedegressredirection
Supportingtrafcmirroringandtrafcstatistics
4CondentialandProprietaryInformationofZTECORPORATION
Chapter2SystemOverview
7.AccessAuthentication
SupportingRADIUSClient
SupportingDHCPRelayandDHCPServer
8.Reliability
SupportingVRRP
Supportingroutingloadbalance
9.NetworkManagement
Supportingcommandlineinterface(CLI)conguration
mode
Supportingcongurationthroughtheconsoleport,Telnet
andSSH
SupportingSNMPandRMON
SupportingNetNumenN31uniednetworkmanagement
system(NMS)
10.ZXR103228A–EI
Supportingthreechannelbackbonenodesignalinput
Supportingvechannelbackbonenodesignaloutput
11.ZXR103928A–PS
Supporting24PoEportswith15.4w-output,providing
seamlessconnectiontoPoE,CISCOIPtelephone,Cisco Aironet®accesspointandcameraandanyterminaldevice meetingIEEE802.3afstandard.
Powerfulandexiblemanagement,powersupplysetting
withmoredetailsthanIEEEstandard

TechnicalFeaturesand Parameters

ZXR103900A/3200Atechnicalfeaturesandparametersarelisted inT able3.
TABLE3ZXR103900A/3200ATECHNICALFEATURESAND PARAMETERS
Item
Dimensions
Description
ZXR103228A:43.6mm(height)×442mm (width)×280mm(depth)
ZXR103228A-FI:43.6mm(height)×442mm (width)×280mm(depth)
ZXR103228A-EI:43.6mm(height)×442mm (width)280mm(depth)
ZXR103252A:43.6mm(height)×442mm (width)×360mm(depth)
CondentialandProprietaryInformationofZTECORPORATION5
ZXR103900A/3200ASeriesHardwareInstallationManual
Item
Description
ZXR103928A:43.6mm(height)×442mm (width)×280mm(depth)
ZXR103928A-PS:43.6mm(height)×442mm (width)×400mm(depth)
ZXR103928A-FI:43.6mm(height)×442mm (width)×280mm(depth)
ZXR103952A:43.6mm(height)×442mm (width)×360mm(depth)
WeightZXR103228A:3.5kg
ZXR103228A-FI:4kg
ZXR103228A-EI:3.5kg
ZXR103252A:4.5kg
ZXR103928A:3.5kg
ZXR103928A-PS:5.9kg
ZXR103928A-FI:4kg
ZXR103952A:4.5kg
PowersupplyACpowersupply:100V~240V ,50Hz~60Hz
DCpowersupply:-57V~-40V
Power consumption
ZXR103228A:20w
ZXR103228A-FI:60w
ZXR103228A-EI:20W
ZXR103252A:35w
ZXR103928A:20w
ZXR103928A-PS:435w(maincontrolbord:65w, MOPofPoE:370w)
ZXR103928A-FI:60w
ZXR103952A:35w
ReliabilityMTBF:>200000hours
MTTR:<30minutes
Lightning
4KV
protection
Environment temperature
Environment
Operatingambienttemperature:-50Cto45
Storagetemperature:-40
Relativehumidity:10%to90%,non-condensing
humidity
Memorysize
ZXR103228A:256M
ZXR103228A-FI:256M
ZXR103228A-EI:256M
ZXR103252A:256M
ZXR103928A:256M
ZXR103928A-PS:256M
ZXR103928A-FI:256M
ZXR103952A:256M
6CondentialandProprietaryInformationofZTECORPORATION
0
C.
0
Cto70
0
C
Chapter2SystemOverview
Item
Switching capacity
Packet forwardingrate
Routingtable entry
MACaddress tabledepth
Description
ZXR103228A:18.8G
ZXR103228A-FI:18.8G
ZXR103228A-EI:18.8G
ZXR103252A:29.6G
ZXR103928A:18.8G
ZXR103928A-PS:18.8G
ZXR103928A-FI:18.8G
ZXR103952A:29.6G
ZXR103228A:13.98M
ZXR103228A-FI:13.98M
ZXR103228A-EI:13.98M
ZXR103252A:22.02M
ZXR103928A:13.98M
ZXR103928A-PS:13.98M
ZXR103928A-FI:13.98M
ZXR103952A:22.02M
ZXR103900A/3200A:12K
ZXR103900A/3200A:16K
CondentialandProprietaryInformationofZTECORPORATION7
ZXR103900A/3200ASeriesHardwareInstallationManual
Thispageisintentionallyblank.
8CondentialandProprietaryInformationofZTECORPORATION
Chapter3

StructureandPrinciple

TableofContents
WorkingPrinciples..............................................................9
HardwareStructure...........................................................10

WorkingPrinciples

ZXR103900A/3200Aseriesproductsarethebox(L3)line-rateEth­ernetswitchesdevelopedbyZTE.Thisseriesswitchesadoptmod­ulardesignandhavestrongcapabilityinservicecontrolanduser managementsoastoprovidenetworkingsolutionstoconvergence ofenterprisenetwork,IPMANnetworkandresidentialblock.
Thisseriesproductshavepowerfulfunctionsandsoundperfor­mance.Accordingtosystemfunctions,theproductscontainthe followingmodules:controlmodule,switchingmodule,interface moduleandpowermodule.
1.Controlmodule:Itcontainsmainprocessorandsomeother externalfunctionalchipsandisusedforsystemtoprocessvar­iousapplications.Itprovidesconsoleportfordatamanipula­tionandmaintenance.
2.Switchingmodule:themainpartofswitchingmoduleispacket processor ,usedforprocessingandswitchingofpacketssent fromports.
3.Interfacemodule:Itiscomposedofinterfacechipsandpe­ripheralscircuitstoconnecttheexternaluserandreceive/send packets.
4.Powermodule:Themoduleadopts220VACor-48VDCtosup­plyneededpowertotheothercomponentswithinthesystem.
5.Monitormodule(providedonlybyZXR103228A-EI):signal inputonthreepairsofbackbonenodes,signaloutputonve pairsofbackbonenodes.
ZXR103900A/3200AsystemprinciplediagramisshowninFigure
1.
CondentialandProprietaryInformationofZTECORPORATION9
ZXR103900A/3200ASeriesHardwareInstallationManual
FIGURE1ZXR103900A/3200ASYSTEMPRINCIPLE
ZXR103900A/3200Asystemadoptsstandard19-inchplug-inbox, whichcanbeinstalledoutsideseparatelyorwithinthestandard cabinet.

HardwareStructure

ZXR103228A

ThechassisheightofZXR103228Ais1U(1U=44.45mm).ZXR10 3228Acansupport24100MpbsEthernetelectricalinterfacesand 2xedgigabitEthernetopticalinterfaces.Theelectricalinterface isRJ45,supportingtwistedpairsofCAT5andabove.Theoptical interfaceisSFP ,supportingvariousgigabitopticalmodulesmeet­ingSFPstandard.Thereisoneslotonthefrontpanel,supporting fourdifferentinterfacecards.
ThefrontpanelofZXR103228AisshowninFigure2.
FIGURE2ZXR103228AFRONTPANEL
ThebackplaneofACpowersupplyinZXR103228Aisshownin
Figure3
FIGURE3ZXR103228ABACKPLANE(AC)
.
10CondentialandProprietaryInformationofZTECORPORATION