Important Safety Information

These warnings are provided in the interest of safety. You MUST read them carefully before installing or using the appliance.

During Operation

Thisappliance hasbeendesignedfornonprofessional purpose in private houses only. It is meant to cook ediblefoodstuffonlyand MUST NOTbeusedforanyother purposes.

It is dangerous to alter the specification in any way.

For hygiene and safety reasons, this appliance should be kept clean at all times. A build-up of fats or other foodstuff could result in a fire.

Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by unexperienced persons may cause injury or serious malfunctioning. Refer to your local Zanussi Service Centre. Always insist on genuine Zanussi spare parts.

Ensure that all control knobs are in the OFF position when not in use.

Should you connect any electrical tool to a plug near this cooking appliance, ensure that electric cables are not in contact with it and keep them far enough from the heated parts of this appliance.

If the appliance is out of order, disconnect it from the electric supply.

Child Safety

This appliance has been designed to be operated by adults and children under supervision. Young children MUST NOT be allowed to tamper with the controls or play

near or with the oven.

Accessible parts of this appliance may become hot when it is in use. Children should be KEPT AWAY until it has cooled.

About Installation, Cleaning

and Manteinance

It is mandatory that all operations required for the installation are carried out by a qualified or competent person, in accordance with existing rules and regulations.

Disconnect the appliance from the electrical supply, beforecarryingoutanycleaningormanteinancework.

Ensure a good ventilation around the appliance. A poor air supply could cause lack of oxygen.

Ensure that the gas supply complies with the gas type stated on the identification label, placed near the gas supply pipe.

Using a gas cooking appliance will produce heat and moisture in the room which it has been installed in. Ensure a continuous air supply, keeping the air vents in good conditions or installing a cooker hood with discharge tube.

In case of intensive or long time use of the appliance, make the ventilation more efficient, by opening a window or increasing the electric exhaust fan power.

Once you removed all packaging from the appliance, ensure that it is not damaged and the electric cable is in perfect conditions. Otherwise, contact your dealer before proceeding with the installation.

The manufacturer disclaims any responsability should all the safety measures not be carried out.

Service

Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by unexperienced persons may cause injury or serious malfunctioning. Refer to your local Service Centre. Always insist on genuine spare parts.

Environmental Information

After installation, please dispose of the packaging with due regard to safety and the environment.

When disposing of an old appliance, make it unusable, by cutting off the cable.

It is most important that this instruction book should be retained with the appliance for future reference. Should the appliance be sold or transferred, always ensure that the book is left with the appliance in order that the new owner can get to know the functions of the appliance and the relevant warnings. These instructions are only for the countries stated by the symbol printed on the front cover of this instruction book.

30

Contents

For the User

 

For the Installer

 

Instruction for the User

31

Technical Data

33

 

 

Cleaning and Maintenance

30

Electrical Connection

34

 

 

Guarantee

40

Adaptation to different types of gas

35

 

 

 

 

Building In

36

Guide to Use the instructions

 

 

 

The following symbols will be found in the text to guide you throughout the Instructions:

Safety Instructions

ΦStep by step instructions for an operation

iHints and Tips

Environmental information

MANUFACTURER:

ELECTROLUX ZANUSSI S.p.A.

Viale Bologna, 298

47100 FORLÌ (Italie)

This appliance complies with the following E.E.C. Directives:

-73/23 - 90/683 (Low Voltage Directive);

-89/336 (Electromagnetical Compatibility Directive);

-93/68(GeneralDirectives) and subsequent modifications.

Instruction for the User

Hob burners control knobs

The hob burners control knobs are situated on the hob right hand side. The symbols on the knobs mean that :

λthere is no gas supply

there is maximum gas supply there is minimum gas supply

Lighting the burners

i

For easier lighting, proceed before putting a

pan on the pan support.

ΦTolightaburner,turntherelevantknobanticlockwise to maximum position and push down the knob to ignite.

Afterlightingtheflame,keeptheknobpusheddown forabout5seconds.Thiswillallowthe"thermocouple" (Fig. 1 lett. C) to be heated and the safety device to be switched off, otherwise the gas supply would be interrupted. Then, check the flame is regular and adjust it as required.

If you cannot light the flame even after several attempts, check the "cap" (Fig. 1 lett. A) is in the correct position.

To put the flame out, turn the knob to the symbol λ.

Always turn the flame down or put it out before taking the pans off the burner.

Fig. 1

FO 2295

 

 

A - Burner cap

 

B - Ignition candle

 

C - Thermocouple

Burner

minimum

maximum

 

diameter

diameter

Big (rapid)

180 mm.

260 mm.

Medium (semirapid)

120 mm.

220 mm.

Small (Auxiliary)

80 mm.

160 mm.

 

 

 

31

Zanussi ZGG754ICN, ZGG753ALU, ZGG754ITAC, ZGG753ICX, ZGG754ICX Manual

Using the hob correctly

To ensure maximum burner efficiency, it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used, so that flame will not spread beyond the bottom of the vessel (see the table beside).

It is also advisable, as soon as a liquid starts boiling, to turn down the flame so that it will barely keep the liquid simmering.

Use only pans or pots with flat bottom.

i Carefully supervise cookings with fatsoroil, since these types of foodstuff can result in a fire, if overheated.

Cleaning and Maintenance

Disconnect the appliance from the electrical supply, before carrying out any cleaning or

manteinance work.

Wash the enamelled components with warm soapy water. Never use abrasive cleaners.

Frequently wash the "caps" and the "crowns" with hot soapy water, carefully taking away any built-up of food. The pan supports are dishwasher proof.

If the marks are particularly difficult to remove, use common non-abrasive cleaners or specific products. Never use steel wool pads or acids.

Regularly wipe over the hob top and the aluminium frame using a soft cloth weel wrung out in warm water to which a little liquid detergent has been added. Avoid the use of the following:

-household detergent and bleaches;

-impregnated pads unsuitable for non-stick saucepans;

-steel wool pads;

-bath/sink stain removers.

Should the hob top become heavily soiled, it is recommended that a proper cleaning product is used. The electric ignition is obtained through a ceramic "candle" and a metal electrode (fig. 1 lett. B). Keep these components well clean, to avoid difficult lighting, and check that the burner crown holes (lett. A) are not obstructed.

The cap and the crown of each burner are secured with two screws. To separate the two pieces, lift the cap, turn it upside down, then undo the two fixing screws as shown in Fig. 3.

After a thorough cleaning, reassemble the two parts and refit the cap in its correct position on the burner.

Periodic maintenance

Periodically ask your local Service Centre to check the conditions of the gas supply pipe and the pressure adjuster, if fitted.

To ensure the good operation of the hob and its safety features, it is necessary that the taps are periodically lubricated.

λThe periodic lubrication of the taps must be carried out by qualified personnel, which you must refer to also in case of malfunctioning.

Fig. 2 FO 2110

Fig. 3 FO 2265

32

Technical Data

Gas Burners Rating

RapidBurner(big)

2,9kW(G20/G25)-2,7kW(G30/G31)

 

 

Semirapid Burner (medium)

1,9 kW

 

 

Auxiliary Burner (small)

1 kW

 

 

 

Appliance Class :

 

3

 

 

 

Category

 

II 2E+3+

 

 

Setting

Natural Gas 20 mbar / G25 25 mbar

 

 

 

Gas connection

 

G 1/2"

 

 

 

Electric Supply

230 V 50 Hz

HOBRECESS

 

DIMENSIONS

 

 

 

Length

560 mm.

 

 

Width

480 mm.

 

 

Instruction for the Installer

λThe following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force. The regulation to be applied for this type of installation is NBN D 5I.003 : "Installations functioning with combustible gas lighter than air".

λThe side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top.

λAvoid installing the appliance in the proximity of inflammable materials (e.g. curtains, tea towels etc.).

λThe appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensureallthenecessaryprecautionsarefollowed.

A)Ramp with ending nut

B)Seal

C)Adjustable connection

FO 2365

Fig. 4

 

Gas connection

It is indispensible that the connection to the gas mains are carried out by means of an AGB tap. Choose fixed connections or use a flexible pipe in AGB (stainless steel).

If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not squeezed. Use the same attention when the hob is combinated with an oven.

This hob can be operated by Slochteren gas (G25) with a nominal pressure of 25 mbar or by natural gas with nominal pressure of 20 mbar. No regulation is required for use by these two types of gas.

Before fitting the appliance ensure that the installation has the correct voltage for the appliance. At full capacity, the drop in pressure must not exceed 5%. Such a drop in pressure is caused by the following parameters:

-maximum capacity of meter;

-diameter and lenght of the tube in front and behind the meter;

-section of transit of variuos tubes positioned on the circuit;

-diameter of eventual connections.

IMPORTANT - To ensure a correct operation, a saving of energy and the long-life of the appliance, the voltage pressure of the appliance must correspond to the recommendedvalues.

The adjustable connection is fixed to the comprehensive ramp by means of a threaded nut GJ 1/2". Interpose the sealing between the components as shown in fig. 4.

Screw the parts without forcing, adjust the connection in the required direction and tighten everything.

IMPORTANT - When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Use some soapy water, never a flame.