Pro Wall Hood Horizontal Discharge Installation
Contents
HORIZONTAL DISCHARGE
1Panel, back
2Bracket, mounting
4Screw, #8 x 3/8"
12Screw, #10 x 11/2"
12Washer, flat #12
1Instructions
Pro 24" and 27" Deep Wall Hoods
WALL PREPARATION
Minimum 2" (51) x 4" (102) lumber is required to construct wall framing. Additional horizontal framing may be required for sufficient anchoring and support.
wolfappliance.com 800.222.7820
HOOD PREPARATION
1Hood is shipped with back panel in place. Damper is attached upside down to inside top surface of back panel. Refer to the illustration below.
2To remove filters, press upward then rotate bottom outward. To aide in removal, remove center filter first. Remove grease cups from bottom edge of hood. Gloves should be worn when handling filters.
3Detach existing back panel and damper assembly from hood by removing the top and back screws. Do not discard screws.
4Turn assembly over and place on a protected work surface. Separate damper from back panel by removing the hold-down brackets. Do not discard brackets and screws. Refer to the illustration below.
WIDTH OF HOOD
|
|
261/4" (667) |
|
|
|||
|
|
MOUNTING CUT-OUT CENTER |
|
|
|||
|
|
13" (330) |
|
|
|
||
15 |
1/16" |
WALL |
10 |
3/4" |
17 |
1/2" |
|
CUT-OUT |
(273) |
||||||
(383) |
(446) |
||||||
|
|
|
|||||
|
|
|
C |
|
|
|
|
|
|
|
L |
|
|
|
GRAY LINES INDICATE VERTICAL AND HORIZONTAL WALL FRAMING
Hood Installation.
DAMPER |
|
BACK PANEL |
|
HOLD-DOWN |
PACKAGING |
|
BRACKET |
MATERIAL |
Damper inside hood. |
Remove damper. |
page 1 of 2