PRECAUTIONS FOR SAFETY

 

• Do not install, repair, open or remove the cover. It may expose you to

 

 

dangerous voltages. Ask the dealer or the specialist to do this.

DANGER

• Turning off the power supply will not prevent potential electric shock.

The appliance shall be installed in accordance with national wiring

 

 

regulation.

 

• Means for disconnection from the supply having a contact separation

 

 

of at least 3 mm in all poles must be incorporated in the fixed wiring.

 

• Do not expose your body directly to cool air for a long time.

 

• Do not insert your finger or any article into the air inlet/outlet.

 

• When an abnormality (burning smell, etc.) occurs, stop the air

 

 

conditioner and disconnect the power supply or turn off the breaker.

WARNING

• This appliance is not intended for use by persons (including

 

children) with reduced physical, sensory or mental capabilities, or

 

 

lack of experience and knowledge, unless they have been given

 

 

supervision or instruction concerning use of the appliance by a

 

 

person responsible for their safety.

 

• Children should be supervised to ensure that they do not play with

 

 

the appliance.

 

• Do not wash the unit with water. It may cause an electric shock.

 

• Do not use this air conditioner for other purposes such as preserving

 

 

food, breeding animal, etc.

 

• Do not step or put anything on the indoor/outdoor unit. It may cause

 

 

an injury or damage the unit.

CAUTION

• Do not touch aluminium fin because it may cause an injury.

Before cleaning the unit, turn off the main switch or the circuit

 

 

breaker.

 

• When the unit won’t be used for a long time, turn off the main switch

 

 

or the circuit breaker.

 

It is recommended that maintenance be performed by a specialist

 

 

when the unit has been operated for a long time.

1 INDOOR UNIT DISPLAY

Models: RAS3SKVR Series

 

 

 

 

Hi POWER (Green)

 

 

 

 

 

4

5

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

FILTER (Orange)

Hi POWER

FILTER

PURE TIMER

OPERATION

3 PURE (Blue)

 

 

 

 

 

 

 

 

 

 

 

 

4

TIMER (Yellow)

1

2

3

 

 

 

 

 

5

OPERATION (Green)

 

 

 

 

 

 

 

 

 

RESET

6

RESET button

 

 

 

 

 

 

 

 

 

6

 

 

 

Models: RAS0SKV Series

 

 

 

 

 

 

 

 

CLEANING

 

 

 

 

 

 

 

1 OPERATION (Green)

 

 

 

 

 

 

 

 

 

 

 

 

2

TIMER/CLEANING (Yellow)

 

RESET

TIMER

OPERATION

 

 

 

3

RESET button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

2

1

 

 

 

 

 

 

 

2 PREPARATION BEFORE USE

Preparing Filters

. Open the air inlet grille and remove the air filters.

2. Attach the fi lters. (see detail in the accessory sheet).

Loading Batteries

. Remove the battery cover.

A

 

CL

2.Insert 2 new batteries (AAA type) following the (+) and (–) positions.

Clock Setup

. Push CLOCK Ο by tip of the pencil.

2. Press

ON or

OFF : adjust the time.

3. Press SET : Set the time.

Remote Control Reset

. Remove the battery.

2. Press .

3. Insert the battery.

3 AIRFLOW DIRECTION

 

 

FIX

1

Press

: Move the louver in the

 

desired vertical direction.

 

 

 

 

 

SWING

2

Press

: Swing the air

 

automatically and press again to stop.

For horizontal direction, adjust 3 manually.

Note:

Do not move the louver manually by others.

The louver may automation positioning by come operation mode.

4 REMOTE CONTROL

1 Infrared signal emitter

2 Start/Stop button

3 Mode select button (MODE)

4 Temperature button (TEMP)

5 Fan speed button (FAN)

6 Swing louver button (SWING)

7 Set louver button (FIX)

8 On timer button (ON)

9 Off timer button (OFF)

! Sleep timer button (SLEEP) " Setup button (SET)

# Clear button (CLR)

$ Memory and Preset button (PRESET) % One Touch button (ONE-TOUCH)

& High power button (Hi-POWER) ( Economy button (ECO)

) Quiet button (QUIET)

~ Comfort sleep button (COMFORT SLEEP)

+Plasma Air Purifier button (PURE) (RAS3SKVR Series Only)

, Filter reset button (FILTER) - Clock Reset button (CLOCK)

. Check button (CHK)

1

$

PRESET

FAN

 

 

TEMP

5

 

ONE-TOUCH

MODE

4

 

 

%

 

 

3

2

 

COMFORT

~

)

QUIET

PURE SLEEP

 

 

 

&

+

SWING FIX

Hi-POWER ECO

(

6

 

 

7

TIMER

CLR

#

8

ON

OFF

9

!

SLEEP

SET

"

.

CHK

FILTER CLOCK

-

 

 

 

,

5 ONE-TOUCH

Press the “ONE-TOUCH” button for fully automated operation that is customised to the typical consumer preferences in your region of the world. The customised settings control temperature air fl ow strength, air fl ow direction and other settings to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer other settings you can select from the many other operating functions of your Toshiba unit.

 

ONE-TOUCH

Press

: Start the operation.

6 AUTOMATIC OPERATION

To automatically select cooling, heating, or fan only operation

 

MODE

. Press

: Select A.

2. Press

TEMP : Set the desired temperature.

7 COOLING / HEATING / FAN ONLY OPERATION

 

MODE

. Press

: Select Cool , Heat , or Fan only .

2. Press

TEMP : Set the desired temperature.

Cooling: Min. 7oC, Heating: Max. 30oC, Fan Only: No temperature indication

FAN

3.Press : Select AUTO, LOW , LOW+ , MED , MED+ , or HIGH .

8 DRY OPERATION (COOLING ONLY)

For dehumidifi cation, a moderate cooling performance is controlled automatically.

MODE

. Press : Select Dry .

2. Press TEMP : Set the desired temperature.

9 AIR PURIFYING OPERATION (RAS-13SKVR Series Only)

During air conditioner operation

PURE

Press to start and stop plasma air purifi er and air ionizer operation.

The plasma air purifi er and air ionizer can be activated or deactivated during air conditioner is stopped and the air ionizer starts in conjunction with plasma air purifi er operation.

Note: The FILTER indicator (orange) turns on after PURE operation is performed for about 000 hours.

10 Hi-POWER OPERATION

To automatically control room temperature and airfl ow for faster cooling or heating

operation (except in DRY and FAN ONLY mode)

Hi-POWER

Press : Start and stop the operation.

11 ECO OPERATION

To automatically control room to save energy (except in DRY and FAN ONLY

mode)

ECO

Press : Start and stop the operation.

Note: Cooling operation; the set temperature will increase automatically degree/ hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.

0250 52.indb 2

2/5/09 2:2 :23 PM

12 TEMPORARY OPERATION

In case of the misplaced or discharged remote control

 

Pressing the RESET button, the unit can start or stop

 

 

without using the remote control.

 

 

 

 

 

 

 

 

Operation mode is set on AUTOMATIC

 

 

 

 

 

 

 

 

 

operation, preset temperature is 24°C

 

 

 

 

 

 

 

 

 

and fan operation is automatic speed.

 

 

 

 

 

 

 

13

TIMER OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the ON Timer

 

 

Setting the OFF Timer

 

1

Press

ON

: Set the desired ON timer.

 

Press

OFF

: Set the desired OFF timer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Press

SET

: Set the timer.

 

Press

SET

: Set the timer.

 

3

Press

CLR

: Cancel the timer.

 

Press

CLR

: Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis.

Setting Daily Timer

1

Press

ON

: Set the ON timer.

3

Press

SET

.

 

 

 

 

 

 

 

 

 

 

 

 

2

Press

OFF

: Set the OFF timer.

4

Press

SET

button during the ( or )

 

 

 

mark fl ashing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During the daily timer is activating, both arrows ( , ) are indicated.

Note:

Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 5 minutes will occur.

The setting will be saved for the next same operation.

14 PRESET OPERATION

Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airfl ow direction).

. Select your preferred operation.

 

PRESET

2. Press and hold

for 3 seconds to memorize the setting. The P mark

displays. PRESET

 

3. Press : Operate the preset operation.

15 AUTO RESTART OPERATION

To automatically restart the conditioner after the power failure (Power of the unit must be on.)

Setting

. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)

• Do not operate ON timer and OFF timer.

2.Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink)

16 QUIET OPERATION

To operate at super low fan speed for quiet operation (except in DRY mode)

QUIET

Press : Start and stop the operation.

Note: Under certain conditions, QUIET operation may not provide adequate cooling or heating due to low sound features.

17 COMFORT SLEEP OPERATION

To save energy while sleeping, automatically control air fl ow and automatically turn OFF.

COMFORT

SLEEP

Press : Select , 3, 5 or 9 hrs for OFF timer operation.

Note: The cooling operation, the set temperature will increase automaticallydegree/hour for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature will decrease.

Cleaning the plasma air purifier unit (About 1000 hours performed) (RAS-13SKVR Series Only)

. Turn off air conditioner using remote control and power supply.

2.Take out the air inlet grille (See detail in installation manual).

3.Take out the plasma air purifi er by grasp the handle, and the pull it out.

4.Soak in hot water at 40oC to 50oC for about 0 to 5 minutes and rub up,

down, left, right and rub surface gently with a sponge. 5. Allow to dry thoroughly in the shade. 6. Attach the plasma air purifi er by grasp the handle

and insert into the right and left guide rails.

7. Press both ends of the plasma air purifi er until the protrusions on both sides of the plasma air purifi er are completely inserted.

8. Attach the air fi lter, and then close the air inlet grille.

20 SELFCLEANINGOPERATION(COOLANDDRYOPERATIONONLY) EN

To protect bad smell caused by the humidity in the indoor unit.

. If the button is pressed once during “Cool” or “Dry” mode, the fan will continue to run for other 20 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.

2. To stop the unit immediately, press the3 times within 30 seconds.

Note:

SELF CLEANING operation is default setting from factory.

To cancel this function, press and hold the reset button on the indoor unit for 20 seconds. TheSELFCLEANINGoperationwillbecancelled.(5beepsoundbutOPERATION lamp does not blink)

Do the same to set this function again. (5 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)

AUTO RESTART operation will be cancelled by setting or cancellation of SELF CLEANING operation. Set it again if necessary.

21 OPERATION AND PERFORMANCE

. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.

2.Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.

3.Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop.

4.Automatic defrosting: Fans will stop during defrost operation.

5.Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner.

6.Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris.

7.Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/contraction of plastic.

Note: Item 2 to 6 for Heating model

Air conditioner operating conditions

Temp.

Outdoor Temperature

Room

 

 

Operation

RAS-13SKVR Series

RAS-10SKV Series

Temperature

Heating

– 5°C ~ 24°C

– 0°C ~ 24°C

Less than 28°C

Cooling

– 0°C ~ 46°C

5°C ~ 43°C

2 °C ~ 32°C

Dry

– 0°C ~ 46°C

5°C ~ 43°C

7°C ~ 32°C

22 TROUBLESHOOTING (CHECK POINT)

The unit does not operate.

Cooling or Heating is abnormally low.

• The power main switch is turned off.

• The fi lters are blocked with dust.

• The circuit breaker is activated to

• The temperature has been set improperly.

cut off the power supply.

• The windows or doors are opened.

• Stoppage of electric current

• The air inlet or outlet of the outdoor

• ON timer is set.

unit is blocked.

The fan speed is too low.

The operation mode is FAN or DRY.

18 SLEEP TIMER OPERATION

To start the sleep timer (OFF timer) operation

PressSLEEP : Select , 3, 5 or 9 hrs for OFF timer operation.

19 MAINTENANCE

Firstly, turn off the circuit breaker.

Filter Reset (Some models only)

FILTER lamp lights on; the fi lter must be cleaned.

To turn off the lamp, push the RESET button on the indoor unit or the FILTER button on the remote control.

Indoor Unit and Remote Control

Clean the indoor unit and the remote control with a wet cloth when needed.

No benzine, thinner, polishing powder or chemically-treated duster.

Cleaning the air ionizer (Once every six months) (RAS-13SKVR Series Only)

. Turn off air conditioner using remote control and power supply.

2.Fully open the vertical air fl ow louvers by hand.

3.Use a toothbrush to rub the ends of metal pin three or four times. Note: Do not use cotton swabs or other objects with fluff.

23 REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly.

Remote Control B Setup.

. Press RESET button on the indoor unit to turn the air conditioner ON.

2.Point the remote control at the indoor unit.

3.Push and hold CHK Ο button on the Remote Control by the tip of the pencil. “00” will

be shown on the display.

 

MODE

4. Press

during pushing CHK Ο. “B” will show on the display and “00”

will disappear and the air conditioner will turn OFF. The Remote Control B is memorized.

Note: . Repeat above step to reset Remote Control to be A. 2. Remote Control A has not “A” display.

3. Default setting of Remote Control from factory is A.