tekmar 540 Quick Start

tekmarNet®4 Thermostat 540
Location1. Remove Mounting Base2.
Interior
Wall
5 feet
1.5 m
Exterior
Wall
Zoning
Q 540
12/11
Replaces: 08/10
Install Mounting Base3.
Plate 007
Thermostat
Base
Switch Settings5.
Switch
1
2
3
4
Adaptor
Thermostat
Base
OR
Switch
Box
Position
ON
OFF OFF No setback schedule response.
ON
OFF OFF No scene response.
ON
OFF
ON Not used
OFF Not used
Action
SETBACK Allow thermostat to respond to
available schedule. Requires Timer 033.
SCENE Allow thermostat to respond to scenes. Requires User Switch 479.
LOCK Locked to ‘User’ access level. Set to Lock when installation completed. UNLOCK Unlock to access all settings. Set to Unlock during installation.
Wall
Wiring4.
Fan
Cooling
G Y R
D
X
Cooling Equipment
tN4 Wiring Center
tN4 Zone Manager
Close Thermostat6.
pivot
tab
1 Stage Cooling
1 Stage
Fan
or
7
G
6
Y
5
Rc
Use at least 75°C conductors For instructions see brochure
tN41C2R3W
tN4 C W
4
R
540
ON
Switch Settings:
1001-01
Scene
Lock
Setback
Unlock
Off
Off
1234
12 34
Not used
Not used
tNt 540
One Stage Heat / One Stage Cool / One Fan
Power: 24 V ±10% 50/60 Hz 1.8 VA 56 VA fully loaded Relays: 24 V (ac) 2 A
Switch Setting Location
Mmm YYYY
Lot # 12345
Meets Class B:
Canadian ICES
FCC Part 15
1 of 2 © 2011 Q 540 - 12/11
User Interface7.
H1
ADJUST
Mode button
Auto, Heat, Cool, Off
Fan button
Switch between Auto or On
Critical Settings8.
The following settings are essential to the successful operation of the system.
Important
setting once installation has been completed.
Toget her
ADJUST
SUPPLY
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual (D540) included with compatible tekmarNet® controls or download the brochure from www.tekmarcontrols.com
Note: Set switch setting #3 and tekmarNet® system control to Unlock to change Access level to Installer. Return to Lock
Press
• Press and hold down both the and buttons for 2 seconds to change from one step to the next.
• Release both buttons once the step has been reached.
+
• Press the or the button to change the setting, if available.
• Press and hold down both the and buttons for 2 seconds to go to the next step, OR
• After 10 seconds of no button activity, the display goes back to normal operation.
Display Range Access Description Set to
°F or °C
Default = °F
Installer
User
TEMPERATURE UNITS
Press the or the button to change from °F to °C and vice versa.
FAN MO DE
Select how the fan should operate together with heating
0, 1, 2, 3
Default = 1
Installer
and cooling. 0 = Manual operation only 1 = Operate fan with cooling only 2 = Operate fan with heating and cooling 3 = Operate fan with heating only
Hyd
(Hydronic)
or Oth
(Other)
Default = Hydronic
Installer
HEATING TERMINAL TYPE
Select if the heating for this zone is hydronic or non­hydronic (other). Available when:
A reset control is present on the tekmarNet®
• system.
HEAT SUPPLY PUMP
During heating, select whether or not the system supply
OFF or On
Default = On
H1
Installer
pump should turn on or be off to allow a zone group pump per manifold. Available when:
A reset control is present on the tekmarNet® system
• AND Heating terminal type is set to Hydronic.
tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A.
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com
Product design, sof tware and literature are Copyright © 2011 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
2 of 2
Head Offi ce: 5100 Silver Star Road,
All specifications are subject to change without notice.
Printed in Canada. Q 540 - 12/11.